Literature DB >> 25128975

The use of pneumatic tourniquet in total knee arthroplasty: a meta-analysis.

Shixiong Yi1, Jixiang Tan, Cheng Chen, Hong Chen, Wei Huang.   

Abstract

BACKGROUND: Pneumatic tourniquet use in total knee arthroplasty (TKA) is always a controversial issue. The aim of the present study is to assess the effectiveness and safety of its use in patients receiving primary unilateral TKA, and to explore the most safe and effective protocols.
MATERIALS AND METHODS: This review was based on cochrane methodology for conducting meta-analysis. Only randomized controlled trials (RCTs) were eligible for this study. The participants were adults who had undergone primary unilateral TKA. The Review Manager Database (RevMan version 5.0, The Cochrane Collaboration 2008) was used to analyze the dates of the selected studies.
RESULTS: Thirteen RCTs involving 859 patients were included in this analysis. The use of tourniquet could significantly reduce operation time (mean difference -5.01 min, P = 0.003), intraoperative blood loss (mean difference -201.85 ml, P < 0.00001) and total blood loss volumes (mean difference -125.03 ml, P = 0.61). But postoperative (mean difference 45.99 ml, P = 0.68) were slightly increased in that situation. With respect to surgical complications, a tendency of increasing risk ratio was observed for tourniquet group.
CONCLUSIONS: Our results indicate that tourniquet application could reduce surgical time, intraoperative blood loss and total blood loss, but increases postoperative total blood loss. With respect to postoperative complications, DVT and surgical site infection rates are relatively augmented in the tourniquet group.

Entities:  

Mesh:

Year:  2014        PMID: 25128975     DOI: 10.1007/s00402-014-2056-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  30 in total

1.  Comparison of quadriceps muscle volume after unilateral total knee arthroplasty with and without tourniquet use.

Authors:  Olcay Guler; Mahir Mahirogullari; Mehmet Isyar; Ahmet Piskin; Sercan Yalcin; Serhat Mutlu; Bünyamin Sahin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-21       Impact factor: 4.342

Review 2.  Soft-tissue damage during total knee arthroplasty: Focus on tourniquet-induced metabolic and ionic muscle impairment.

Authors:  Constantin Mayer; Alexander Franz; Jan-Frieder Harmsen; Fina Queitsch; Michael Behringer; Johannes Beckmann; Rüdiger Krauspe; Christoph Zilkens
Journal:  J Orthop       Date:  2017-06-24

3.  Effects of different methods of using pneumatic tourniquet in patients undergoing total knee arthroplasty: a randomized control trial.

Authors:  Y Zhang; D Li; P Liu; X Wang; M Li
Journal:  Ir J Med Sci       Date:  2017-03-04       Impact factor: 1.568

4.  Tourniquet application during TKA did not affect the accuracy of implant positioning: a randomized clinical trial.

Authors:  Vera Stetzelberger; Udo Obertacke; Ahmed Jawhar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-10-20       Impact factor: 4.342

5.  Silicone ring tourniquet or pneumatic cuff tourniquet for total knee arthroplasty.

Authors:  Jean-Yves Jenny; David Bahlau; Sandra Wisniewski
Journal:  Int Orthop       Date:  2016-03-16       Impact factor: 3.075

6.  Vascular calcifications on the preoperative radiograph: harbinger of tourniquet failure in patients undergoing total knee arthroplasty?

Authors:  Julia Verena Woelfle-Roos; Laura Dautel; Benjamin Mayer; Ralf Bieger; Klaus-Dieter Woelfle; Heiko Reichel
Journal:  Skeletal Radiol       Date:  2017-06-05       Impact factor: 2.199

7.  Tourniquet-induced ischaemia during total knee arthroplasty results in higher proteolytic activities within vastus medialis cells: a randomized clinical trial.

Authors:  Ahmed Jawhar; Stephan Hermanns; Norbert Ponelies; Udo Obertacke; Henning Roehl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-14       Impact factor: 4.342

8.  Reduced length of stay and faster recovery after total knee arthroplasty without the use of tourniquet.

Authors:  Serajdin Ajnin; Richard Fernandes
Journal:  J Clin Orthop Trauma       Date:  2019-08-26

9.  Silicone ring tourniquet versus pneumatic cuff tourniquet in total knee arthroplasty surgery: A randomised comparative study.

Authors:  Vicente J León-Muñoz; Alonso J Lisón-Almagro; César H Hernández-García; Mirian López-López
Journal:  J Orthop       Date:  2018-05-07

10.  The knee position at tourniquet inflation does not affect the gap balancing during total knee arthroplasty.

Authors:  Yoshio Matsui; Masanori Matsuura; Noriaki Hidaka
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-05       Impact factor: 3.067