Hakan Arslan1, Ertuğrul Karataş2, Ismail Davut Capar3, Damla Ozsu2, Ezgi Doğanay2. 1. Department of Endodontics, Faculty of Dentistry, Ataturk University, Erzurum, Turkey. Electronic address: dt_hakan82@hotmail.com. 2. Department of Endodontics, Faculty of Dentistry, Ataturk University, Erzurum, Turkey. 3. Department of Endodontics, Faculty of Dentistry, Katip Çelebi University, İzmir, Turkey.
Abstract
INTRODUCTION: The aim of the present study was to evaluate crack formation after flaring root canals with Gates Glidden drills and ProTaper Universal (SX; Dentsply Maillefer, Ballaigues, Switzerland), Endoflare (MicroMega, Besançon, France), Revo-S (MicroMega), and HyFlex (Coltene-Whaledent, Allstetten, Switzerland) flaring instruments. METHODS: One-hundred eight mandibular molars were selected. Eighteen teeth were left unprepared to serve as negative controls; the experimental groups consisted of the mesiobuccal and mesiolingual root canals of the remaining 90 teeth, which were instrumented with the following coronal flaring instruments: Gates Glidden drills and ProTaper Universal SX, Endoflare, Revo-S SC1, and HyFlex 25.08 instruments. All roots were then sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the cementoenamel junction. The sections were inspected under a stereomicroscope, and any crack formations were recorded. The data were analyzed using the chi-square test (P = .05). RESULTS: The Gates Glidden drills resulted in a higher rate of crack formation than that noted in the control group (P < .05). Flaring of the root canals using the ProTaper Universal, Endoflare, Revo-S, and HyFlex instruments resulted in crack formation similar to that of the control group (P > .05). CONCLUSIONS: The use of the Gates Glidden drills resulted in the formation of the most cracks. However, the results for the ProTaper Universal, Endoflare, Revo-S, and HyFlex flaring instruments were similar to those of the control group in terms of crack formation.
INTRODUCTION: The aim of the present study was to evaluate crack formation after flaring root canals with Gates Glidden drills and ProTaper Universal (SX; Dentsply Maillefer, Ballaigues, Switzerland), Endoflare (MicroMega, Besançon, France), Revo-S (MicroMega), and HyFlex (Coltene-Whaledent, Allstetten, Switzerland) flaring instruments. METHODS: One-hundred eight mandibular molars were selected. Eighteen teeth were left unprepared to serve as negative controls; the experimental groups consisted of the mesiobuccal and mesiolingual root canals of the remaining 90 teeth, which were instrumented with the following coronal flaring instruments: Gates Glidden drills and ProTaper Universal SX, Endoflare, Revo-S SC1, and HyFlex 25.08 instruments. All roots were then sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the cementoenamel junction. The sections were inspected under a stereomicroscope, and any crack formations were recorded. The data were analyzed using the chi-square test (P = .05). RESULTS: The Gates Glidden drills resulted in a higher rate of crack formation than that noted in the control group (P < .05). Flaring of the root canals using the ProTaper Universal, Endoflare, Revo-S, and HyFlex instruments resulted in crack formation similar to that of the control group (P > .05). CONCLUSIONS: The use of the Gates Glidden drills resulted in the formation of the most cracks. However, the results for the ProTaper Universal, Endoflare, Revo-S, and HyFlex flaring instruments were similar to those of the control group in terms of crack formation.
Authors: Paula Barcellos da Silva; Simone Ferreti Duarte; Murilo Priori Alcalde; Marco Antonio Húngaro Duarte; Rodrigo Ricci Vivan; Ricardo Abreu da Rosa; Marcus Vinícius Reis Só; Angela Longo do Nascimento Journal: BMC Oral Health Date: 2020-04-16 Impact factor: 2.757