Literature DB >> 25125371

Reference ranges for the volumes of fetal cardiac ventricular walls by three-dimensional ultrasound using spatiotemporal image correlation and virtual organ computer-aided analysis and its validation in fetuses with congenital heart diseases.

Fernanda Silveira Bello Barros1, Liliam Cristine Rolo, Luciane Alves Rocha, Wellington P Martins, Luciano Marcondes Machado Nardozza, Antonio Fernandes Moron, Fabrício Da Silva Costa, Edward Araujo Júnior.   

Abstract

OBJECTIVE: To establish reference values for the volumes of fetal cardiac ventricular walls using three-dimensional ultrasonography (3DUS) and perform data validation using fetuses with confirmed congenital heart disease (CHD).
METHODS: This prospective, cross-sectional study analyzed 371 singleton pregnancies between 20w0d and 33w6d of gestation. Ventricular volumes were assessed using spatiotemporal image correlation (STIC) and virtual organ computer-aided analysis (VOCAL). We calculated the polynomial regressions, adjusted by the coefficient of determination (R(2) ). To assess intra-observer concordance, the intraclass correlation coefficient (ICC) was used. To validate the curves, the ventricular wall volumes of 22 fetuses with CHD were evaluated.
RESULTS: There was a good correlation between these mean volumes and gestational age, and this correlation was best represented by linear equations. Intra-observer concordance in assessing the volumes of the right (ICC = 0.90) and left ventricular walls (ICC = 0.97) was good. We observed that the volumes of the right and left ventricular walls were altered (<5(th) percentile and/or >95(th) percentile) in 8/22 fetuses presenting with CHD.
CONCLUSION: The reference ranges for the volumes of the right and left ventricular walls by 3DUS using STIC and VOCAL between 20w0d and 33w6d of gestation were determinate, and they exhibited good intra-observer concordance.
© 2014 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2014        PMID: 25125371     DOI: 10.1002/pd.4480

Source DB:  PubMed          Journal:  Prenat Diagn        ISSN: 0197-3851            Impact factor:   3.050


  5 in total

1.  Prospective evaluation of the fetal heart using Fetal Intelligent Navigation Echocardiography (FINE).

Authors:  M Garcia; L Yeo; R Romero; D Haggerty; I Giardina; S S Hassan; T Chaiworapongsa; E Hernandez-Andrade
Journal:  Ultrasound Obstet Gynecol       Date:  2016-03-10       Impact factor: 7.299

2.  A Prospective Study of the Use of Fetal Intelligent Navigation Echocardiography (FINE) to Obtain Standard Fetal Echocardiography Views.

Authors:  Paola Veronese; Gianna Bogana; Alessia Cerutti; Lami Yeo; Roberto Romero; Maria Teresa Gervasi
Journal:  Fetal Diagn Ther       Date:  2016-06-17       Impact factor: 2.587

3.  Fetal Interventricular Septum Volume Evaluated by Three-Dimensional Ultrasound Using Spatiotemporal Image Correlation and Virtual Organ Computer-Aided Analysis in Fetuses From Pre-Gestational Diabetes Mellitus Pregnant Women.

Authors:  Nathalie Jeanne Bravo-Valenzuela; Alberto Borges Peixoto; Rosiane Mattar; Edward Araujo Júnior
Journal:  J Cardiovasc Imaging       Date:  2022-04

Review 4.  Fetal cardiac function by three-dimensional ultrasound using 4D-STIC and VOCAL - an update.

Authors:  Nathalie Jeanne Bravo-Valenzuela; Alberto Borges Peixoto; Milene Carvalho Carrilho; Ana Letícia Siqueira Pontes; Caroline Cevante Chagas; Christiane Simioni; Edward Araujo Júnior
Journal:  J Ultrason       Date:  2019-12-31

5.  Novel foetal echocardiographic image processing software (5D Heart) improves the display of key diagnostic elements in foetal echocardiography.

Authors:  Wan-Yu Hu; Jin-Hong Zhou; Xiao-Ying Tao; Shi-Yan Li; Bei Wang; Bo-Wen Zhao
Journal:  BMC Med Imaging       Date:  2020-04-03       Impact factor: 1.930

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.