Correction-less dosimetry of nonstandard photon fields: a new criterion to determine the usability of radiation detectors.

Y Kamio, H Bouchard.   

Abstract

In the IAEA-AAPM dosimetry formalism, detector measurements in general nonstandard conditions are corrected using the factor k(f(clin),f(msr))(Q(clin),Q(msr)). This factor needs to be evaluated on a case-by-case basis which is difficult to accomplish in practice. The present paper aims to provide a method that allows neglecting correction factors for small and composite IMRT fields by first determining a radiation detector's usability in these fields. Detailed models of nine radiation detectors are built: four ionization chambers (NE2571, A12, A1SL, A14), three small field detectors (PTW31018 microLion, PTW60003 natural diamond, PTW60012 unshielded diode) and two near water-equivalent detectors (alanine, W1 scintillating fiber). Using the egs_chamber Monte Carlo code, dose response functions at 6 MV and 25 MV are sampled for each detector and their corresponding volume of water. These functions are then used with a newly derived criterion to evaluate an upper bound ξ(f(ns),f(msr))(Q(ns),Q(msr)) on the variable ε(f(ns),f(msr))(Q(ns),Q(msr)) if no field collimation/modulation occurs over a given perturbation zone. The variable ε(f(ns),f(msr))(Q(ns),Q(msr)) is defined as the absolute value of the relative deviation from unity of a nonstandard field quality correction factor k(f(ns),f(msr))(Q(ns),Q(msr)). Using the same criterion, perturbation zones are evaluated by finding the smallest field size allowed for correction-less dosimetry with a given tolerance ξ(f(ns),f(msr))(Q(ns),Q(msr)). For composite fields, the sensitivity of detectors to the non-uniformity of virtual symmetric collapsed beams over regions of interest specified by the criterion is studied to estimate an upper bound ξ ̃(f(ns),f(ref))(Q(ns),Q) on ε(f(ns),f(ref))(Q(ns),Q) for a given beam flatness. Finally, a newly defined perturbation function is used to minimize the perturbations of the microLion chamber through density compensation. The theoretical criterion shows good agreement with full Monte Carlo simulations of ε(f(ns),f(msr))(Q(ns) Q(msr)). Perturbation zones are shown to be sensitive to both the energy of the beam and the orientation of the detector. The density-compensated microLion shows significantly improved response in both axial and radial orientations in small and composite IMRT fields. Finally, the new Exradin W1 scintillator is shown to have ξ(f(ns),f(msr))(Q(ns),Q(msr)) values under 1% in small fields. The methods presented in this work theoretically show that correction-less dosimetry of nonstandard field can be accomplished by knowing the limit of usability of radiation detectors in these conditions. Potential applications include small field output factor measurements and absolute absorbed dose to water verification in the QA of clinical IMRT fields.

Entities:  

Mesh:

Year:  2014        PMID: 25118890     DOI: 10.1088/0031-9155/59/17/4973

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Output factor determination based on Monte Carlo simulation for small cone field in 10-MV photon beam.

Authors:  Kyohei Fukata; Satoru Sugimoto; Chie Kurokawa; Akito Saito; Tatsuya Inoue; Keisuke Sasai
Journal:  Radiol Phys Technol       Date:  2018-04-04

2.  Effect of Magnetic Field Strength on Plastic Scintillation Detector Response.

Authors:  F Therriault-Proulx; Z Wen; G Ibbott; S Beddar
Journal:  Radiat Meas       Date:  2018-06-09       Impact factor: 1.898

3.  Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators.

Authors:  Madelaine K Tyler; Paul Z Y Liu; Christopher Lee; David R McKenzie; Natalka Suchowerska
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

4.  An analytical formalism for the assessment of dose uncertainties due to positioning uncertainties.

Authors:  Wolfgang Lechner; Dietmar Georg; Hugo Palmans
Journal:  Med Phys       Date:  2020-01-26       Impact factor: 4.071

5.  Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams.

Authors:  Attia Gul; Shigekazu Fukuda; Hideyuki Mizuno; Nakaji Taku; M Basim Kakakhel; Sikander M Mirza
Journal:  J Appl Clin Med Phys       Date:  2020-10-19       Impact factor: 2.243

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.