Literature DB >> 25118193

Balloon-augmented Onyx embolization of cerebral arteriovenous malformations using a dual-lumen balloon: a multicenter experience.

Alejandro M Spiotta1, Robert F James2, Stephen R Lowe1, Jan Vargas1, Aquilla S Turk3, M Imran Chaudry3, Tarun Bhalla4, Rashid M Janjua5, John J Delaney6, Stacey Quintero-Wolfe5, Raymond D Turner1.   

Abstract

INTRODUCTION: Conventional Onyx embolization of cerebral arteriovenous malformations (AVMs) requires lengthy procedure and fluoroscopy times to form an adequate 'proximal plug' which allows forward nidal penetration while preventing reflux and non-targeted embolization. We review our experience with balloon-augmented Onyx embolization of cerebral AVMs using a dual-lumen balloon catheter technique designed to minimize these challenges.
METHODS: Retrospectively acquired data for all balloon-augmented cerebral AVM embolizations performed between 2011 and 2014 were obtained from four tertiary care centers. For each procedure, at least one Scepter C balloon catheter was advanced into the AVM arterial pedicle of interest and Onyx embolization was performed through the inner lumen after balloon inflation via the outer lumen.
RESULTS: Twenty patients underwent embolization with the balloon-augmented technique over 24 discreet treatment episodes. There were 37 total arterial pedicles embolized with the balloon-augmented technique, a mean of 1.9 per patient (range 1-5). The treated AVMs were heterogeneous in their location and size (mean 3.3±1.6 cm). Mean fluoroscopy time for each procedure was 48±26 min (28 min per embolized pedicle). Two Scepter C balloon catheter-related complications (8.3% of embolization sessions, 5.4% of pedicles embolized) were observed: an intraprocedural rupture of a feeding pedicle and fracture and retention of a catheter fragment.
CONCLUSIONS: This multicenter experience represents the largest reported series of balloon-augmented Onyx embolization of cerebral AVMs. The technique appears safe and effective in the treatment of AVMs, allowing more efficient and controlled injection of Onyx with a decreased risk of reflux and decreased fluoroscopy times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

Entities:  

Keywords:  Arteriovenous Malformation

Mesh:

Substances:

Year:  2014        PMID: 25118193     DOI: 10.1136/neurintsurg-2014-011285

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  21 in total

1.  [Intracranial vascular malformations].

Authors:  D F Vollherbst; M Bendszus; M A Möhlenbruch
Journal:  Nervenarzt       Date:  2018-10       Impact factor: 1.214

2.  Intermixed Dimethyl-Sulfoxide-Based Nonadhesive Liquid Embolic Agents Delivered Serially via the Same Microcatheter for Cerebral AVM Treatment.

Authors:  A Sirakov; K Minkin; S Sirakov
Journal:  AJNR Am J Neuroradiol       Date:  2020-03-12       Impact factor: 3.825

Review 3.  Advances in Biomaterials and Technologies for Vascular Embolization.

Authors:  Jingjie Hu; Hassan Albadawi; Brian W Chong; Amy R Deipolyi; Rahul A Sheth; Ali Khademhosseini; Rahmi Oklu
Journal:  Adv Mater       Date:  2019-06-06       Impact factor: 30.849

4.  Percutaneous use of a dual lumen Scepter XC balloon for embolization of a complex facial arteriovenous malformation: a technical report.

Authors:  Jeremy Heit; Ian Connolly; Omar Choudhri
Journal:  Clin Neuroradiol       Date:  2016-05-03       Impact factor: 3.649

5.  The use of dual-lumen balloon for embolization of peripheral arteriovenous malformations.

Authors:  Tales V C Albuquerque; Dimitrius Nikolaos Jaconi Stamoulis; Lucas M Monsignore; Luis Henrique de Castro-Afonso; Guilherme Seizem Nakiri; Marco Tulio Rezende; Felipe Padovani Trivelato; José Ricardo Vanzin; Alexandre Cordeiro Ulhoa; Daniel G Abud
Journal:  Diagn Interv Radiol       Date:  2021-03       Impact factor: 2.630

6.  A novel, non-adhesive, precipitating liquid embolic implant with intrinsic radiopacity: feasibility and safety animal study.

Authors:  Zsolt Kulcsár; Agnieszka Karol; Peter W Kronen; Pfundstein Svende; Karina Klein; Olivier Jordan; Isabel Wanke
Journal:  Eur Radiol       Date:  2016-06-14       Impact factor: 5.315

7.  Dual-lumen balloon catheters may improve liquid embolization of vascular malformations: an experimental study in Swine.

Authors:  J C Gentric; J Raymond; A Batista; I Salazkin; G Gevry; T E Darsaut
Journal:  AJNR Am J Neuroradiol       Date:  2015-01-15       Impact factor: 3.825

8.  Incidental occlusion of anterior spinal artery due to Onyx reflux in embolization of spinal type II arteriovenous malformation.

Authors:  Joohyun Kim; Jang-Bo Lee; Tai-Hyoung Cho; Junseok W Hur
Journal:  Eur Spine J       Date:  2016-09-26       Impact factor: 3.134

9.  Complications of Endovascular Treatments for Brain Arteriovenous Malformations: A Nationwide Surveillance.

Authors:  K Sato; Y Matsumoto; T Tominaga; T Satow; K Iihara; N Sakai
Journal:  AJNR Am J Neuroradiol       Date:  2020-03-19       Impact factor: 3.825

10.  Water-Borne Endovascular Embolics Inspired by the Undersea Adhesive of Marine Sandcastle Worms.

Authors:  Joshua P Jones; Monika Sima; Ryan G O'Hara; Russell J Stewart
Journal:  Adv Healthc Mater       Date:  2016-01-25       Impact factor: 9.933

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.