Literature DB >> 25109901

Model validation of untethered, ultrasonic neural dust motes for cortical recording.

Dongjin Seo1, Jose M Carmena2, Jan M Rabaey3, Michel M Maharbiz3, Elad Alon3.   

Abstract

A major hurdle in brain-machine interfaces (BMI) is the lack of an implantable neural interface system that remains viable for a substantial fraction of the user's lifetime. Recently, sub-mm implantable, wireless electromagnetic (EM) neural interfaces have been demonstrated in an effort to extend system longevity. However, EM systems do not scale down in size well due to the severe inefficiency of coupling radio-waves at those scales within tissue. This paper explores fundamental system design trade-offs as well as size, power, and bandwidth scaling limits of neural recording systems built from low-power electronics coupled with ultrasonic power delivery and backscatter communication. Such systems will require two fundamental technology innovations: (1) 10-100 μm scale, free-floating, independent sensor nodes, or neural dust, that detect and report local extracellular electrophysiological data via ultrasonic backscattering and (2) a sub-cranial ultrasonic interrogator that establishes power and communication links with the neural dust. We provide experimental verification that the predicted scaling effects follow theory; (127 μm)(3) neural dust motes immersed in water 3 cm from the interrogator couple with 0.002064% power transfer efficiency and 0.04246 ppm backscatter, resulting in a maximum received power of ∼0.5 μW with ∼1 nW of change in backscatter power with neural activity. The high efficiency of ultrasonic transmission can enable the scaling of the sensing nodes down to 10s of micrometer. We conclude with a brief discussion of the application of neural dust for both central and peripheral nervous system recordings, and perspectives on future research directions.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Backscatter communication; Brain–machine interfaces; Chronic extra-cellular recording systems; Ultrasonic energy harvesting

Mesh:

Year:  2014        PMID: 25109901     DOI: 10.1016/j.jneumeth.2014.07.025

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  29 in total

1.  Implantable wireless battery recharging system for bladder pressure chronic monitoring.

Authors:  Darrin J Young; Peng Cong; Michael A Suster; Margot Damaser
Journal:  Lab Chip       Date:  2015-11-21       Impact factor: 6.799

2.  Fusing multiple neuroimaging modalities to assess group differences in perception-action coupling.

Authors:  Jordan Muraskin; Jason Sherwin; Gregory Lieberman; Javier O Garcia; Timothy Verstynen; Jean M Vettel; Paul Sajda
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2016-07-15       Impact factor: 10.961

Review 3.  Closed-loop neuromodulation systems: next-generation treatments for psychiatric illness.

Authors:  Meng-Chen Lo; Alik S Widge
Journal:  Int Rev Psychiatry       Date:  2017-02-10

4.  Neural Recording and Modulation Technologies.

Authors:  Ritchie Chen; Andres Canales; Polina Anikeeva
Journal:  Nat Rev Mater       Date:  2017-01-04       Impact factor: 66.308

5.  Recent Advances in Neural Electrode-Tissue Interfaces.

Authors:  Kevin Woeppel; Qianru Yang; Xinyan Tracy Cui
Journal:  Curr Opin Biomed Eng       Date:  2017-09-23

Review 6.  Roadmap on semiconductor-cell biointerfaces.

Authors:  Bozhi Tian; Shuai Xu; John A Rogers; Stefano Cestellos-Blanco; Peidong Yang; João L Carvalho-de-Souza; Francisco Bezanilla; Jia Liu; Zhenan Bao; Martin Hjort; Yuhong Cao; Nicholas Melosh; Guglielmo Lanzani; Fabio Benfenati; Giulia Galli; Francois Gygi; Rylan Kautz; Alon A Gorodetsky; Samuel S Kim; Timothy K Lu; Polina Anikeeva; Michal Cifra; Ondrej Krivosudský; Daniel Havelka; Yuanwen Jiang
Journal:  Phys Biol       Date:  2018-03-09       Impact factor: 2.583

7.  Ultrasound-Induced Wireless Energy Harvesting: From Materials Strategies to Functional Applications.

Authors:  Laiming Jiang; Yang Yang; Yong Chen; Qifa Zhou
Journal:  Nano Energy       Date:  2020-07-22       Impact factor: 17.881

8.  Electronically integrated, mass-manufactured, microscopic robots.

Authors:  Marc Z Miskin; Alejandro J Cortese; Kyle Dorsey; Edward P Esposito; Michael F Reynolds; Qingkun Liu; Michael Cao; David A Muller; Paul L McEuen; Itai Cohen
Journal:  Nature       Date:  2020-08-26       Impact factor: 49.962

9.  A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication.

Authors:  David K Piech; Benjamin C Johnson; Konlin Shen; M Meraj Ghanbari; Ka Yiu Li; Ryan M Neely; Joshua E Kay; Jose M Carmena; Michel M Maharbiz; Rikky Muller
Journal:  Nat Biomed Eng       Date:  2020-02-19       Impact factor: 25.671

10.  A Comprehensive Comparative Study on Inductive and Ultrasonic Wireless Power Transmission to Biomedical Implants.

Authors:  Ahmed Ibrahim; Miao Meng; Mehdi Kiani
Journal:  IEEE Sens J       Date:  2018-03-05       Impact factor: 3.301

View more