Nanochannel array device operating through Prussian blue nanoparticles for sensitive label-free immunodetection of a cancer biomarker.

Marisol Espinoza-Castañeda1, Alfredo de la Escosura-Muñiz1, Alejandro Chamorro2, Carmen de Torres3, Arben Merkoçi4.   

Abstract

A novel nanochannel array (NC) device that operates through Prussian blue nanoparticles (PBNPs) as redox indicator for sensitive label free immunodetection of a cancer biomarker is presented. Stable and narrow-sized (around 4 nm) PBNPs, protected by polyvinylpyrrolidone, exhibited a well-defined and reproducible redox behavior and were successfully applied for the voltammetric evaluation of the nanochannels (20 nm pore sized) blockage due to the immunocomplex formation. The bigger size of the PBNPs compared with ionic indicators such as the [Fe(CN)6](4-/3-) system leads to an increase in the steric effects hindering their diffusion toward the signaling electrode which in turn is transduced to an improvement of the detection limit from 200 µg mL(-1) to 34 pg human IgG mL(-1). This novel and effective PBNPs-NC technology for the detection of small proteins captured inside the nanochannels is successfully applied for the quantification of a cancer biomarker (parathyroid hormone-related protein, PTHrP) in a real clinical scenario such as cell culture medium. The achieved label-free detection of PTHrP at levels of 50 ng mL(-1) is with great interest to study relevant functions that this protein exerts in normal tissues and cancer.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Cancer biomarker; Nanochannels; Prussian blue nanoparticles

Mesh:

Substances:

Year:  2014        PMID: 25103338     DOI: 10.1016/j.bios.2014.07.039

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

Review 1.  Recent Advances in Electrochemical Immunosensors.

Authors:  Benoît Piro; Steeve Reisberg
Journal:  Sensors (Basel)       Date:  2017-04-07       Impact factor: 3.576

2.  A Visual FRET Immunofluorescent Biosensor for Ratiometric Parathyroid Hormone (1-84) Antigen Point-of-Care Detection.

Authors:  Yixin Nie; Jingting Li; Yang Liu; Qian Zhang; Qiang Ma
Journal:  J Fluoresc       Date:  2020-02-04       Impact factor: 2.217

3.  An electrochemical membrane-based aptasensor for detection of severe acute respiratory syndrome coronavirus-2 receptor-binding domain.

Authors:  Mahmoud Amouzadeh Tabrizi; Pablo Acedo
Journal:  Appl Surf Sci       Date:  2022-05-30       Impact factor: 7.392

4.  Cost-effective and sensitive colorimetric immunosensing using an iron oxide-to-Prussian blue nanoparticle conversion strategy.

Authors:  Guanglei Fu; Sharma T Sanjay; XiuJun Li
Journal:  Analyst       Date:  2016-05-03       Impact factor: 4.616

5.  Nanobiosensors in diagnostics.

Authors:  Alejandro Chamorro-Garcia; Arben Merkoçi
Journal:  Nanobiomedicine (Rij)       Date:  2016-11-24

Review 6.  Nanoparticles as Emerging Labels in Electrochemical Immunosensors.

Authors:  Alba Iglesias-Mayor; Olaya Amor-Gutiérrez; Agustín Costa-García; Alfredo de la Escosura-Muñiz
Journal:  Sensors (Basel)       Date:  2019-11-23       Impact factor: 3.576

7.  Electrochemical Biosensors Based on Convectively Assembled Colloidal Crystals.

Authors:  Amane Shiohara; Christopher D Easton; Beatriz Prieto-Simon; Nicolas H Voelcker
Journal:  Biosensors (Basel)       Date:  2022-06-30

8.  Porous Alumina Membrane-Based Electrochemical Biosensor for Protein Biomarker Detection in Chronic Wounds.

Authors:  Gayathri Rajeev; Elizabeth Melville; Allison J Cowin; Beatriz Prieto-Simon; Nicolas H Voelcker
Journal:  Front Chem       Date:  2020-03-06       Impact factor: 5.221