Literature DB >> 25099077

Findings related to rotational malalignment in tibial fractures treated with reamed intramedullary nailing.

Ferhat Say1, Murat Bülbül.   

Abstract

INTRODUCTION: Rotational malalignment following closed intramedullary nailing of tibial fractures does not attract attention but is a complication which may lead to serious results. This study aimed to present findings related to rotational malalignment from rotational alignment measurements made clinically and with computerised tomography (CT) in patients who had undergone locked intramedullary nailing for tibial fracture.
MATERIALS AND METHODS: A total of 26 patients (male/female: 23/3) were evaluated after application of reamed locking intramedullary nailing to a diagnosed tibial shaft fracture. The mean age was determined as 37.5 ± 15.6 years. Rotational alignment was measured in both lower extremities clinically as thigh-foot angle (TFA) and radiologically with CT. Rotational malalignment was accepted as a more than 10º difference between the two lower extremities.
RESULTS: Malrotation was determined at more than 10º from TFA in two (7 %) of 26 patients and from CT in five (19 %) of 26 patients. In three of them, the malrotation was >15º. Of the patients determined with malrotation with CT, it was determined from clinical measurements in 40 %. The mean rotational difference was determined as greater with CT measurement (4.7° ± 9.5) compared to the TFA (1.1° ± 5.6) (p < 0.001). No statistically significant relationship was determined between a rotational difference over 10º and the AO fracture type, fracture location and fibula fixation.
CONCLUSIONS: A significant number of patients treated with intramedullary nailing for a tibial fracture may result in rotational malalignment. To determine rotational malalignment, a thorough clinical evaluation must be made and different kinds of clinical measurements taken and, when suspicions remain, determination should be made by CT.

Entities:  

Mesh:

Year:  2014        PMID: 25099077     DOI: 10.1007/s00402-014-2052-2

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  8 in total

1.  Clinical Faceoff: Suprapatellar Tibial Nailing for Tibia Fractures.

Authors:  Lisa K Cannada; Hassan R Mir; Stephen A Kottmeier
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.176

2.  Intraoperative fluoroscopic protocol to avoid rotational malalignment after nailing of tibia shaft fractures: introduction of the 'C-Arm Rotational View (CARV)'.

Authors:  Nils Jan Bleeker; Job N Doornberg; Kaj Ten Duis; Mostafa El Moumni; Inge H F Reininga; Ruurd L Jaarsma; Frank F A IJpma
Journal:  Eur J Trauma Emerg Surg       Date:  2022-07-30       Impact factor: 2.374

3.  Intraoperative torsion control using the cortical step sign and diameter difference in tibial mid-shaft fractures.

Authors:  Christian Zeckey; C Neuerburg; Alexander M Keppler; Konstantin Küssner; Eduardo M Suero; Veronika Kronseder; Wolfgang Böcker; Christian Kammerlander
Journal:  Eur J Trauma Emerg Surg       Date:  2021-01-02       Impact factor: 2.374

Review 4.  Safe surgical technique: intramedullary nail fixation of tibial shaft fractures.

Authors:  Boris A Zelle; Guilherme Boni
Journal:  Patient Saf Surg       Date:  2015-12-12

5.  Do the Loss of Thigh Muscle Strength and Tibial Malrotation Cause Anterior Knee Pain after Tibia Intramedullary Nailing?

Authors:  Emre Anıl Özbek; Mahmut Kalem; Hakan Kınık
Journal:  Biomed Res Int       Date:  2019-03-27       Impact factor: 3.411

6.  Application of the multiplanar fracture redactor in the treatment of tibial shaft fractures with intramedullary nails.

Authors:  Kuo Zhao; Hongzhi Lv; Chun Zhang; Zhongzheng Wang; Zhiyong Hou; Wei Chen; Qi Zhang; Yingze Zhang
Journal:  Sci Rep       Date:  2021-04-19       Impact factor: 4.379

7.  Clinical assessment of tibial torsion differences. Do we always need a computed tomography?

Authors:  Humam Hawi; Till Frederik Kaireit; Christian Krettek; Emmanouil Liodakis
Journal:  Eur J Trauma Emerg Surg       Date:  2022-02-10       Impact factor: 2.374

8.  Radiographic cortical thickness parameters as predictors of rotational alignment in proximal tibial shaft fractures: a cadaveric study.

Authors:  Alexander M Keppler; Konstantin Küßner; Anna-Lena Schulze; Eduardo M Suero; Carl Neuerburg; Maximilian Weigert; Christian Braun; Wolfgang Böcker; Christian Kammerlander; Christian Zeckey
Journal:  BMC Musculoskelet Disord       Date:  2021-06-26       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.