Literature DB >> 2509587

Stress shielding effect of rigid internal fixation plates on mandibular bone grafts. A photon absorption densitometry and quantitative computerized tomographic evaluation.

M C Kennady1, M R Tucker, G E Lester, M J Buckley.   

Abstract

The use of rigid internal fixation reconstruction plates in combination with bone grafts provides many advantages in mandibular reconstruction. These advantages include ease of adaptability at the time of surgery as well as immediate postoperative function for the patient. Disadvantages may include a "stress shielding" or disuse osteoporosis effect on the underlying bone graft as a result of the rigidity of the reconstruction plate. This study evaluated the stress shielding effects on bone grafts in primate mandibles. Bilateral bone grafts stabilized with rigid fixation plates were performed in 4 Macaca fascicularis monkeys. Three months after the bone grafting procedure one plate was removed from each monkey. The monkeys were then killed 1, 4, 6 and 8 months after plate removal. Photon absorption densitometry and computerized tomography were used to evaluate stress shielding. The results of this study indicate that the stress shielding effect occurs if the plate is not removed from the area of bone grafting postoperatively.

Entities:  

Mesh:

Year:  1989        PMID: 2509587     DOI: 10.1016/s0901-5027(89)80101-8

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  12 in total

1.  Treatment of tripod fracture of zygomatic bone by N-2-butyl cyanoacrylate glue fixation, and its effects on the tissues.

Authors:  Burhan Dadaş; Seyhan Alkan; Memet Cifci; Tülay Başak
Journal:  Eur Arch Otorhinolaryngol       Date:  2007-01-04       Impact factor: 2.503

Review 2.  Mini-plate versus reconstruction bar fixation for oncologic mandibular reconstruction with free fibula flaps: A systematic review and meta-analysis.

Authors:  Nikhil Sobti; Kaleem S Ahmed; Thais Polanco; Marina Chilov; Marc A Cohen; Jay Boyle; Farooq Shahzad; Evan Matros; Jonas A Nelson; Robert J Allen
Journal:  J Plast Reconstr Aesthet Surg       Date:  2022-05-06       Impact factor: 3.022

3.  Management of pediatric mandibular fractures using bioresorbable plating system - Efficacy, stability, and clinical outcomes: Our experiences and literature review.

Authors:  Mahinder Singh; R K Singh; Deepak Passi; Mohit Aggarwal; Guneet Kaur
Journal:  J Oral Biol Craniofac Res       Date:  2015-10-17

4.  BONE RESPONSE TO STAINLESS STEEL AND TITANIUM BONE PLATES: An Experimental Study On Animals.

Authors:  N K Sahoo; S C Anand; J R Bhardwaj; V P Sachdeva; B L Sapru
Journal:  Med J Armed Forces India       Date:  2017-06-27

5.  Viscoelastic and biological performance of low-modulus, reactive calcium phosphate-filled, degradable, polymeric bone adhesives.

Authors:  Ensanya A Abou Neel; Vehid Salih; Peter A Revell; Anne M Young
Journal:  Acta Biomater       Date:  2011-08-17       Impact factor: 8.947

Review 6.  Strategies for Enhancing Polyester-Based Materials for Bone Fixation Applications.

Authors:  Raasti Naseem; Charalampos Tzivelekis; Matthew J German; Piergiorgio Gentile; Ana M Ferreira; Kenny Dalgarno
Journal:  Molecules       Date:  2021-02-13       Impact factor: 4.411

7.  Patient-Specific 3D-Printed Miniplates for Free Flap Fixation at the Mandible: A Feasibility Study.

Authors:  Kilian Kreutzer; Claudius Steffen; Steffen Koerdt; Christian Doll; Tobias Ebker; Susanne Nahles; Tabea Flügge; Max Heiland; Benedicta Beck-Broichsitter; Carsten Rendenbach
Journal:  Front Surg       Date:  2022-03-14

8.  Ti-24Nb-4Zr-8Sn Alloy Pedicle Screw Improves Internal Vertebral Fixation by Reducing Stress-Shielding Effects in a Porcine Model.

Authors:  Yang Qu; Shuang Zheng; Rongpeng Dong; Mingyang Kang; Haohan Zhou; Dezhi Zhao; Jianwu Zhao
Journal:  Biomed Res Int       Date:  2018-02-08       Impact factor: 3.411

9.  Miniplate removal in operated cases of maxillofacial region in a dental institute in Rajasthan, India.

Authors:  Pulkit Khandelwal; A Bhagavandas Rai; Bipin Bulgannawar; Nilay Vakaria; Hemal Sejani; Neha Hajira
Journal:  Med Pharm Rep       Date:  2019-10-25

Review 10.  Patient-specific finite element models of the human mandible: Lack of consensus on current set-ups.

Authors:  Bram Barteld Jan Merema; Joep Kraeima; Haye H Glas; Fred K L Spijkervet; Max J H Witjes
Journal:  Oral Dis       Date:  2020-07-09       Impact factor: 3.511

View more