Electron microscopy of laser capsulotomy edge: Interplatform comparison.

Chandra Bala1, Yong Xia2, Kerrie Meades2.   

Abstract

PURPOSE: To perform a morphological comparison of capsulotomy edges generated by commercially available femtosecond lasers with manual capsulorhexis.
SETTING: Private clinic.
DESIGN: Experimental study.
METHODS: Capsules were collected using the following laser platforms and software versions: Lensx pre-soft-fit (version 2.16), Lensx post-soft-fit (version 2.20), Victus I (version 2.5), Victus II (version 2.7SP2), Catalys (version 2.15.13), and 10 manual. Scanning electron microscopy images were analyzed for the coefficient of variation (CoV) of pixilation along the capsule edge and homogeneity using gray-level co-occurrence matrix analysis. A qualitative assessment for anomalies, such as tags, was also made.
RESULTS: The mean CoV values from the regression analysis showed the manual edge (n = 10) (101.6% ± 0.6% [SD]) was smoother than the edges created with Lensx pre-soft-fit (105.2% ± 1.2%) (P<.001), Lensx post-soft-fit (102.7% ± 1.4%) (P=.04), Victus I (104.9% ± 0.9%) (P<.001), Catalys (104.5% ± 1.6%) (P<.001), and Victus II (104.7% ± 1.6%) platforms. All lasers (0.19 to 0.23) (P<.001) except the Lensx post-soft-fit (0.25 ± 0.03) (P=.23) generated less homogenous capsulotomies than the manual technique (0.27 ± 0.04). Tags occurred with Lensx pre-soft-fit (5/10), Lensx post-soft-fit (1/10), Victus I (1/4), and Victus II (3/10) platforms. Misdirected pulses were seen with the Catalys (4/10) and Victus II (4/10) platforms, which used fluid interfaces.
CONCLUSIONS: Laser capsulotomies are approaching the smoothness of the manual capsulorhexis. The Lensx post-soft-fit platform showed the least anomalies and the smallest difference for the CoV and homogeneity metrics compared with the manual method. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25088639     DOI: 10.1016/j.jcrs.2013.11.045

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

Review 1.  Update and clinical utility of the LenSx femtosecond laser in cataract surgery.

Authors:  Timothy V Roberts; Michael Lawless; Gerard Sutton; Chris Hodge
Journal:  Clin Ophthalmol       Date:  2016-10-17

2.  Comparison of Maximum Stretch Forces between Femtosecond Laser-Assisted Capsulotomy and Continuous Curvilinear Capsulorhexis.

Authors:  Mari Takagi; Takashi Kojima; Kei Ichikawa; Yoshiki Tanaka; Yukihito Kato; Rie Horai; Akeno Tamaoki; Kazuo Ichikawa
Journal:  J Ophthalmol       Date:  2017-01-22       Impact factor: 1.909

3.  Scanning Electron Microscopy Analysis of the Anterior Capsulotomy Edge: A Comparative Study between Femtosecond Laser-Assisted Capsulotomy and Manual Capsulorhexis.

Authors:  Daniele Tognetto; Chiara De Giacinto; Alberto Armando Perrotta; Tommaso Candian; Alessandro Bova; Silvia Rinaldi; Gianluca Turco
Journal:  J Ophthalmol       Date:  2018-11-14       Impact factor: 1.909

4.  The effects of a low-energy, high frequency liquid optic interface femtosecond laser system on lens capsulotomy.

Authors:  Geraint P Williams; Ben L George; Yoke R Wong; Xin-Yi Seah; Heng-Pei Ang; Mun Kitt A Loke; Shian Chao Tay; Jod S Mehta
Journal:  Sci Rep       Date:  2016-04-19       Impact factor: 4.379

5.  Electron microscopy analysis of femtosecond laser-assisted capsulotomy before and after lens fragmentation.

Authors:  Wolfgang J Mayer; Andreas Ohlmann; Anna Schuh; Siegfried Priglinger; Thomas Kohnen; Mehdi Shajari
Journal:  Sci Rep       Date:  2021-12-24       Impact factor: 4.379