Literature DB >> 25086481

Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites.

Simon Flury1, Anne Peutzfeldt2, Adrian Lussi2.   

Abstract

OBJECTIVES: To investigate the influence of increment thickness on Vickers microhardness (HV) and shear bond strength (SBS) to dentin of a conventional and four bulk fill resin composites.
METHODS: HV and SBS were determined on specimens of the conventional resin composite Filtek Supreme XTE (XTE) and the bulk fill resin composites SDR (SDR), Filtek Bulk Fill (FBF), x-tra fil (XFIL), and Tetric EvoCeram Bulk Fill (TEBF) after 24h storage. HV was measured either as profiles at depths up to 6mm or at the bottom of 2mm/4mm/6mm thick resin composite specimens. SBS of 2mm/4mm/6mm thick resin composite increments was measured to dentin surfaces of extracted human molars treated with the adhesive system OptiBond FL, and the failure mode was stereomicroscopically determined at 40× magnification. HV profiles and failure modes were descriptively analysed whereas HV at the bottom of resin composite specimens and SBS were statistically analysed with nonparametric ANOVA followed by Wilcoxon rank sum tests (α=0.05).
RESULTS: HV profiles (medians at 2mm/4mm/6mm): XTE 105.6/88.8/38.3, SDR 34.0/35.5/36.9, FBF 36.4/38.7/37.1, XFIL 103.4/103.9/101.9, TEBF 63.5/59.7/51.9. HV at the bottom of resin composite specimens (medians at 2mm/4mm/6mm): XTE (p<0.0001) 105.5>85.5>31.1, SDR (p=0.10) 25.8=21.9=26.0, FBF (p=0.16) 26.6=25.3=28.9, XFIL (p=0.18) 110.5=107.2=101.9, TEBF (p<0.0001) 63.0>54.9>48.2. SBS (MPa, medians at 2mm/4mm/6mm): XTE (p<0.0001) 23.9>18.9=16.7, SDR (p=0.26) 24.6=22.7=23.4, FBF (p=0.11) 21.4=20.3=22.0, x-tra fil (p=0.55) 27.0=24.0=23.6, TEBF (p=0.11) 21.0=20.7=19.0. The predominant SBS failure mode was cohesive failure in dentin. SIGNIFICANCE: At increasing increment thickness, HV and SBS decreased for the conventional resin composite but generally remained constant for the bulk fill resin composites.
Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dentin bonding; Depth of cure; Light-curing; Posterior restorative; Surface hardness

Mesh:

Substances:

Year:  2014        PMID: 25086481     DOI: 10.1016/j.dental.2014.07.001

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  24 in total

1.  Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites.

Authors:  Sufyan Garoushi; Pekka Vallittu; Akikazu Shinya; Lippo Lassila
Journal:  Odontology       Date:  2015-12-11       Impact factor: 2.634

2.  Halloysite nanotube incorporation into adhesive systems—effect on bond strength to human dentin.

Authors:  Mohammed S Alkatheeri; Jadesada Palasuk; George J Eckert; Jeffrey A Platt; Marco C Bottino
Journal:  Clin Oral Investig       Date:  2015-02-10       Impact factor: 3.573

3.  Thirty-six-month clinical evaluation of posterior high-viscosity bulk-fill resin composite restorations in a high caries incidence population: interim results of a randomized clinical trial.

Authors:  Márcia de Almeida Durão; Ana Karina Maciel de Andrade; Amanda Maciel do Prado; Sirley Raiane Mamede Veloso; Lynn Morena Tavares Maciel; Marcos Antônio Japiassú Resende Montes; Gabriela Queiroz de Melo Monteiro
Journal:  Clin Oral Investig       Date:  2021-04-06       Impact factor: 3.573

4.  The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites.

Authors:  Matej Par; Igor Repusic; Hrvoje Skenderovic; Ognjen Milat; Jelena Spajic; Zrinka Tarle
Journal:  Clin Oral Investig       Date:  2019-01-28       Impact factor: 3.573

5.  Evaluation of cavity wall adaptation of bulk esthetic materials to restore class II cavities in primary molars.

Authors:  Maria D Gaintantzopoulou; Vellore K Gopinath; Spiros Zinelis
Journal:  Clin Oral Investig       Date:  2016-05-10       Impact factor: 3.573

6.  Influence of increment thickness on dentin bond strength and light transmission of composite base materials.

Authors:  Tarek A Omran; Sufyan Garoushi; Aous A Abdulmajeed; Lippo V Lassila; Pekka K Vallittu
Journal:  Clin Oral Investig       Date:  2016-09-10       Impact factor: 3.573

Review 7.  [Factors influencing clinical application of bulk-fill composite resin].

Authors:  Jing Xue
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-06-01

8.  Marginal quality of a full-body bulk-fill composite placed with an universal adhesive system in etch-and-rinse and self-etch mode: An in vitrostudy.

Authors:  Antonio Signore; Luca Solimei; Marianna-Georgievna Arakelyan; Alina-Vladimirova Arzukanyan; Nicola De Angelis; Andrea Amaroli
Journal:  J Clin Exp Dent       Date:  2021-08-01

9.  Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis.

Authors:  Frank Engelhardt; Sebastian Hahnel; Verena Preis; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2016-01-09       Impact factor: 3.573

10.  Could sonic delivery of bulk-fill resins improve the bond strength and cure depth in extended size class I cavities?

Authors:  Karla-Janilee-de Souza Penha; Ana-Ferreira Souza; Marina-Jansen Dos Santos; Lauber-José Dos Santos-Almeida Júnior; Rudys-Rodolfo-De Jesus Tavarez; Leily-Macedo Firoozmand
Journal:  J Clin Exp Dent       Date:  2020-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.