Literature DB >> 25082169

A study of measurement of noninvasive blood pressure with the oscillometric device, Sentinel, in isoflurane-anaesthetized horses.

Lea-Annina Hatz1, Sonja Hartnack2, Jan Kümmerle3, Michael Hässig4, Regula Bettschart-Wolfensberger1.   

Abstract

OBJECTIVE: To assess accuracy of noninvasive blood pressure (NIBP) measured by oscillometric device Sentinel compared to invasive blood pressure (IBP) in anaesthetized horses undergoing surgery. To assess if differences between the NIBP measured by the Sentinel and IBP are associated with recumbency, cuff placement, weight of the horse or acepromazine premedication and to describe usefulness of the Sentinel. STUDY
DESIGN: Prospective study examining replicates of simultaneous NIBP and IBP measurements. ANIMALS: Twenty-nine horses.
METHODS: Invasive blood pressure was measured via a catheter in the facial artery, transverse facial artery or metatarsal artery. NIBP was measured using appropriate size cuffs placed on one of two metacarpal or metatarsal bones or the tail in random order. With both techniques systolic (SAP), mean (MAP), and diastolic (DAP) arterial blood pressures and heart rates (HR) were recorded. A mixed effects model compared the IBP to the NIBP values and assessed potential effects of catheter placement, localisation of the cuffs in combination with recumbency, weight of the horse or acepromazine premedication.
RESULTS: Noninvasive blood pressure yielded higher measurements than IBP. Agreement varied with recumbency and cuff position. Estimated mean differences between the two methods decreased from SAP (lateral recumbency: range -5.3 to -56.0 mmHg; dorsal recumbency: range 0.8 to -20.7 mmHg), to MAP (lateral recumbency: range -1.8 to -19.0 mmHg; dorsal recumbency: range 13.9 to -16.4 mmHg) to DAP (lateral recumbency: range 0.5 to -6.6 mmHg; dorsal recumbency: range 21.0 to -15.5 mmHg). NIBP measurement was approximately two times more variable than IBP measurement. No significant difference between IBP and NIBP due to horse's weight or acepromazine premedication was found. In 227 of 1047 (21.7%) measurements the Sentinel did not deliver a result. CONCLUSION AND CLINICAL RELEVANCE: According to the high variability of NIBP compared to IBP, NIBP measurements as measured by the Sentinel in the manner described here are not considered as an appropriate alternative to IBP to measure blood pressure in anaesthetized horses.
© 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

Entities:  

Keywords:  Sentinel; anaesthesia; horses; invasive blood pressure monitoring; non-invasive blood pressure monitoring

Mesh:

Substances:

Year:  2014        PMID: 25082169     DOI: 10.1111/vaa.12213

Source DB:  PubMed          Journal:  Vet Anaesth Analg        ISSN: 1467-2987            Impact factor:   1.648


  5 in total

1.  Diagnostic value of noninvasive pulse pressure measurements in Warmblood horses with aortic regurgitation.

Authors:  Julia Boegli; Colin C Schwarzwald; Katharyn J Mitchell
Journal:  J Vet Intern Med       Date:  2019-04-02       Impact factor: 3.333

2.  Differences in ultrasound-derived arterial wall stiffness parameters and noninvasive blood pressure between Friesian horses and Warmblood horses.

Authors:  Lisse Vera; Dominique De Clercq; Glenn Van Steenkiste; Annelies Decloedt; Koen Chiers; Gunther van Loon
Journal:  J Vet Intern Med       Date:  2020-02-07       Impact factor: 3.333

3.  Bias Associated with Peripheral Non-Invasive Compared to Invasive Arterial Blood Pressure Monitoring in Healthy Anaesthetised and Standing Horses Using the Bionet BM7Vet.

Authors:  Shaun Pratt; Tamsin S Barnes; Nicholas Cowling; Karla de Klerk; Joanne Rainger; Albert Sole-Guitart; Solomon Woldeyohannes; Wendy Goodwin
Journal:  Vet Sci       Date:  2022-01-28

4.  Agreement of High-Definition Oscillometry (HDO) and Invasive Blood Pressure Measurements at a Metatarsal Artery in Isoflurane-Anaesthetised Horses.

Authors:  Lara Twele; Stephan Neudeck; Julien Delarocque; Nicole Verhaar; Julia Reiners; Mike Noll; Julia Tünsmeyer; Sabine B R Kästner
Journal:  Animals (Basel)       Date:  2022-02-02       Impact factor: 2.752

5.  Effects of xylazine and adrenaline combinations: Preliminary clinical application for non-surgical protocols of nephrosplenic entrapment in horses.

Authors:  Worakij Cherdchutham; Patskit Sukhong; Kanchanog Sae-Oueng; Nithisphat Supanwinijkul; Kittanai Wiangnak; Jirayut Srimuang; Tawanhathai Apichaimongkonkun; Sarocha Limratchapong; Soontaree Petchdee
Journal:  Vet World       Date:  2021-12-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.