Literature DB >> 25074663

The use of modified four-dimensional computed tomography in patients with primary hyperparathyroidism: an argument for the abandonment of routine sestamibi single-positron emission computed tomography (SPECT).

Moshim Kukar1, Timothy A Platz, Timothy J Schaffner, Rania Elmarzouky, Adrienne Groman, Shicha Kumar, Ahmed Abdelhalim, William G Cance.   

Abstract

BACKGROUND: Four-dimensional computed tomography (4D CT) has emerged as an extremely sensitive preoperative imaging modality for primary hyperparathyroidism compared with the historical use of sestamibi and ultrasound (US). Specialized volume rendering and technical modifications further enhance this technique for operative guidance while reducing radiation exposure.
METHODS: Patients undergoing parathyroidectomy for primary hyperparathyroidism from December 2010 to September 2013, carried out by two surgeons at a tertiary cancer center, were evaluated. Comparison was made between the three imaging modalities (4D CT, sestamibi, and US) for preoperative localization rate and accuracy. Biochemical parameters and radiation exposure were also analyzed.
RESULTS: A total of 202 patients were identified from the database and 200 patients were included in the analysis. All patients underwent 4D CT (100 %), 185 sestamibi (92.5 %) and 186 US (93 %). In patients with single-gland disease (n = 153), 4D CT, sestamibi, and US were positive in 96 %, 65.4 % and 57.7 % of patients, respectively and, when positive, were accurately localized in 97.2 %, 93.4 % and 96.3 % of patients, respectively. In patients with multigland disease (MGD) [n = 47], 4D CT, sestamibi, and US predicted MGD in 32 %, 0 %, and 13.6 % of patients, respectively. With our technique modification, radiation exposure from 4D CT approached that of sestamibi.
CONCLUSIONS: Low-dose, modified 4D CT with volume rendering when compared with sestamibi has a statistically significant higher positivity rate, improved accuracy rate, provides excellent images, superior surgical planning, and has a comparable radiation exposure risk profile. Consideration should be made for the abandonment of routine sestamibi single-positron emission computed tomography (SPECT), with 4D CT as the preoperative imaging modality of choice.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25074663     DOI: 10.1245/s10434-014-3940-y

Source DB:  PubMed          Journal:  Ann Surg Oncol        ISSN: 1068-9265            Impact factor:   5.344


  15 in total

1.  Diagnostic Performance of 4D CT and Sestamibi SPECT/CT in Localizing Parathyroid Adenomas in Primary Hyperparathyroidism.

Authors:  Randy Yeh; Yu-Kwang Donovan Tay; Gaia Tabacco; Laurent Dercle; Jennifer H Kuo; Leonardo Bandeira; Catherine McManus; David K Leung; James A Lee; John P Bilezikian
Journal:  Radiology       Date:  2019-03-05       Impact factor: 11.105

2.  Clinical efficacy of 2-phase versus 4-phase computed tomography for localization in primary hyperparathyroidism.

Authors:  Adriana G Ramirez; Amber L Shada; Allison N Martin; Prashant Raghavan; Christopher R Durst; Sugoto Mukherjee; John R Gaughen; David A Ornan; John B Hanks; Philip W Smith
Journal:  Surgery       Date:  2016-06-11       Impact factor: 3.982

3.  Predictors of Multigland Disease in Primary Hyperparathyroidism: A Scoring System with 4D-CT Imaging and Biochemical Markers.

Authors:  A R Sepahdari; M Bahl; A Harari; H J Kim; M W Yeh; J K Hoang
Journal:  AJNR Am J Neuroradiol       Date:  2015-01-02       Impact factor: 3.825

Review 4.  Pediatric hyperparathyroidism: review and imaging update.

Authors:  Hedieh Khalatbari; Safia H E Cheeney; Scott C Manning; Marguerite T Parisi
Journal:  Pediatr Radiol       Date:  2021-04-27

5.  Assessment of 4DCT imaging findings of parathyroid adenomas in correlation with biochemical and histopathological findings.

Authors:  Ekim Gumeler; Olcay Kurtulan; Sevtap Arslan; Jale Karakaya; Cenk Sokmensuer; Ugur Unluturk; Kader K Oguz; Ayca Akgoz Karaosmanoglu
Journal:  Jpn J Radiol       Date:  2021-11-23       Impact factor: 2.374

6.  Prospective Validation of Two 4D-CT-Based Scoring Systems for Prediction of Multigland Disease in Primary Hyperparathyroidism.

Authors:  S Sho; M Yilma; M W Yeh; M Livhits; J X Wu; J K Hoang; A R Sepahdari
Journal:  AJNR Am J Neuroradiol       Date:  2016-09-22       Impact factor: 3.825

7.  PRIMARY HYPERPARATHYROIDISM - STRATEGY FOR MULTIGLAND DISEASE IN THE ERA OF SPECT-CT.

Authors:  I T Cvasciuc; W Ismail; M Lansdown
Journal:  Acta Endocrinol (Buchar)       Date:  2017 Jan-Mar       Impact factor: 0.877

8.  Factors Associated With Discordance Between Preoperative Parathyroid 4-Dimensional Computed Tomographic Scans and Intraoperative Findings During Parathyroidectomy.

Authors:  Shonan Sho; Alexander D Yuen; Michael W Yeh; Masha J Livhits; Ali R Sepahdari
Journal:  JAMA Surg       Date:  2017-12-01       Impact factor: 14.766

9.  Usefulness of the Wisconsin and CaPTHUS indices for predicting multiglandular disease in patients with primary hyperparathyroidism in a southern European population.

Authors:  Mario Serradilla-Martín; Ana Palomares-Cano; Miguel Cantalejo-Díaz; Mónica Mogollón-González; Esther Brea-Gómez; Nuria Victoria Muñoz-Pérez; Juan Ignacio Arcelus-Martínez; Jesús María Villar-Del-Moral
Journal:  Gland Surg       Date:  2021-03

Review 10.  The role of imaging in pelvic exenteration for gynecological cancers.

Authors:  Pamela Ines Causa Andrieu; Sungmin Woo; Eric Rios-Doria; Yukio Sonoda; Soleen Ghafoor
Journal:  Br J Radiol       Date:  2021-05-07       Impact factor: 3.629

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.