Literature DB >> 25071956

Optimization of camera exposure durations for multi-exposure speckle imaging of the microcirculation.

S M Shams Kazmi1, Satyajit Balial1, Andrew K Dunn1.   

Abstract

Improved Laser Speckle Contrast Imaging (LSCI) blood flow analyses that incorporate inverse models of the underlying laser-tissue interaction have been used to develop more quantitative implementations of speckle flowmetry such as Multi-Exposure Speckle Imaging (MESI). In this paper, we determine the optimal camera exposure durations required for obtaining flow information with comparable accuracy with the prevailing MESI implementation utilized in recent in vivo rodent studies. A looping leave-one-out (LOO) algorithm was used to identify exposure subsets which were analyzed for accuracy against flows obtained from analysis with the original full exposure set over 9 animals comprising n = 314 regional flow measurements. From the 15 original exposures, 6 exposures were found using the LOO process to provide comparable accuracy, defined as being no more than 10% deviant, with the original flow measurements. The optimal subset of exposures provides a basis set of camera durations for speckle flowmetry studies of the microcirculation and confers a two-fold faster acquisition rate and a 28% reduction in processing time without sacrificing accuracy. Additionally, the optimization process can be used to identify further reductions in the exposure subsets for tailoring imaging over less expansive flow distributions to enable even faster imaging.

Keywords:  (110.6150) Speckle imaging; (170.0170) Medical optics and biotechnology

Year:  2014        PMID: 25071956      PMCID: PMC4102356          DOI: 10.1364/BOE.5.002157

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  38 in total

1.  Absolute blood velocity measured with a modified fundus camera.

Authors:  Donald D Duncan; Paul Lemaillet; Mohamed Ibrahim; Quan Dong Nguyen; Matthias Hiller; Jessica Ramella-Roman
Journal:  J Biomed Opt       Date:  2010 Sep-Oct       Impact factor: 3.170

2.  Determination of optimal exposure time for imaging of blood flow changes with laser speckle contrast imaging.

Authors:  Shuai Yuan; Anna Devor; David A Boas; Andrew K Dunn
Journal:  Appl Opt       Date:  2005-04-01       Impact factor: 1.980

3.  Efficient processing of laser speckle contrast images.

Authors:  W James Tom; Adrien Ponticorvo; Andrew K Dunn
Journal:  IEEE Trans Med Imaging       Date:  2008-12       Impact factor: 10.048

4.  Quantitative laser speckle flowmetry of the in vivo microcirculation using sidestream dark field microscopy.

Authors:  Annemarie Nadort; Rutger G Woolthuis; Ton G van Leeuwen; Dirk J Faber
Journal:  Biomed Opt Express       Date:  2013-10-07       Impact factor: 3.732

5.  Improved cerebral blood flow measurement with multiexposure speckle imaging.

Authors:  Ian R Winship
Journal:  J Cereb Blood Flow Metab       Date:  2013-04-10       Impact factor: 6.200

6.  Anterior and posterior optic nerve head blood flow in nonhuman primate experimental glaucoma model measured by laser speckle imaging technique and microsphere method.

Authors:  Lin Wang; Grant A Cull; Chelsea Piper; Claude F Burgoyne; Brad Fortune
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-12-17       Impact factor: 4.799

7.  Laser speckle contrast analysis: a new method to evaluate peripheral blood perfusion in systemic sclerosis patients.

Authors:  Barbara Ruaro; Alberto Sulli; Elisa Alessandri; Carmen Pizzorni; Giorgia Ferrari; Maurizio Cutolo
Journal:  Ann Rheum Dis       Date:  2013-08-16       Impact factor: 19.103

8.  Laser speckle contrast imaging of collateral blood flow during acute ischemic stroke.

Authors:  Glenn A Armitage; Kathryn G Todd; Ashfaq Shuaib; Ian R Winship
Journal:  J Cereb Blood Flow Metab       Date:  2010-06-02       Impact factor: 6.200

9.  Comparison of indocyanine green angiography and laser speckle contrast imaging for the assessment of vasculature perfusion.

Authors:  Erica L Towle; Lisa M Richards; S M Shams Kazmi; Douglas J Fox; Andrew K Dunn
Journal:  Neurosurgery       Date:  2012-11       Impact factor: 4.654

10.  Spreading depression triggers headache by activating neuronal Panx1 channels.

Authors:  Hulya Karatas; Sefik Evren Erdener; Yasemin Gursoy-Ozdemir; Sevda Lule; Emine Eren-Koçak; Zümrüt Duygu Sen; Turgay Dalkara
Journal:  Science       Date:  2013-03-01       Impact factor: 47.728

View more
  10 in total

1.  High-speed multi-exposure laser speckle contrast imaging with a single-photon counting camera.

Authors:  Tanja Dragojević; Danilo Bronzi; Hari M Varma; Claudia P Valdes; Clara Castellvi; Federica Villa; Alberto Tosi; Carles Justicia; Franco Zappa; Turgut Durduran
Journal:  Biomed Opt Express       Date:  2015-07-14       Impact factor: 3.732

2.  Accessing to arteriovenous blood flow dynamics response using combined laser speckle contrast imaging and skin optical clearing.

Authors:  Rui Shi; Min Chen; Valery V Tuchin; Dan Zhu
Journal:  Biomed Opt Express       Date:  2015-05-06       Impact factor: 3.732

3.  Flux or speed? Examining speckle contrast imaging of vascular flows.

Authors:  S M Shams Kazmi; Ehssan Faraji; Mitchell A Davis; Yu-Yen Huang; Xiaojing J Zhang; Andrew K Dunn
Journal:  Biomed Opt Express       Date:  2015-06-18       Impact factor: 3.732

4.  Multiple speckle exposure imaging for the study of blood flow changes induced by functional activation of barrel cortex and olfactory bulb in mice.

Authors:  Haleh Soleimanzad; François Smekens; Juliette Peyronnet; Marjorie Juchaux; Olivier Lefebvre; David Bouville; Christophe Magnan; Hirac Gurden; Frederic Pain
Journal:  Neurophotonics       Date:  2019-03-05       Impact factor: 3.593

5.  Sensitivity of laser speckle contrast imaging to flow perturbations in the cortex.

Authors:  Mitchell A Davis; Louis Gagnon; David A Boas; Andrew K Dunn
Journal:  Biomed Opt Express       Date:  2016-02-03       Impact factor: 3.732

6.  Simultaneously extracting multiple parameters via multi-distance and multi-exposure diffuse speckle contrast analysis.

Authors:  Jialin Liu; Hongchao Zhang; Jian Lu; Xiaowu Ni; Zhonghua Shen
Journal:  Biomed Opt Express       Date:  2017-09-19       Impact factor: 3.732

7.  Intraoperative multi-exposure speckle imaging of cerebral blood flow.

Authors:  Lisa M Richards; Sm Shams Kazmi; Katherine E Olin; James S Waldron; Douglas J Fox; Andrew K Dunn
Journal:  J Cereb Blood Flow Metab       Date:  2017-01-23       Impact factor: 6.200

8.  Dynamics of isoflurane-induced vasodilation and blood flow of cerebral vasculature revealed by multi-exposure speckle imaging.

Authors:  Colin T Sullender; Lisa M Richards; Fei He; Lan Luan; Andrew K Dunn
Journal:  J Neurosci Methods       Date:  2021-12-01       Impact factor: 2.987

Review 9.  Expanding applications, accuracy, and interpretation of laser speckle contrast imaging of cerebral blood flow.

Authors:  S M Shams Kazmi; Lisa M Richards; Christian J Schrandt; Mitchell A Davis; Andrew K Dunn
Journal:  J Cereb Blood Flow Metab       Date:  2015-05-06       Impact factor: 6.200

10.  Synthetic exposure with a CMOS camera for multiple exposure speckle imaging of blood flow.

Authors:  M Chammas; F Pain
Journal:  Sci Rep       Date:  2022-03-18       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.