Literature DB >> 25070931

Multielectrode Pulmonary Vein Ablation Catheter (PVAC(®)): current data on results and risks.

Gerold Mönnig1, Lars Eckardt.   

Abstract

Electrical isolation of pulmonary veins is the cornerstone of catheter ablation for patients with symptomatic atrial fibrillation. However, uncertainty surrounds the choice of energy source in pulmonary vein isolation (PVI). Various alternative techniques such as the Pulmonary Vein Ablation Catheter (PVAC(®), Medtronic Inc., Minneapolis, MN, USA) have been developed to facilitate PVI. This over-the-wire multielectrode catheter is delivering duty-cycled bipolar and unipolar radiofrequency (RF) energy at relatively low power.PVI with this "one-shot" PVACatheter can shorten the procedure duration and lower fluoroscopy time compared to irrigated RF. It enables mapping and ablation with the same array, but fails to show signals during RF energy delivery. The effectiveness of PVAC is comparable to other technologies in randomized studies. The overall complication rate of PVAC PVI is comparable to irrigated RF and possibly slightly higher for cryoballoon PVI. Special attention has to be paid to an effective anticoagulation throughout the ablation procedure, avoidance of embolic events and pulmonary venous stenosis.The novel catheter design of the PVAC Gold(®) array may improve safety by reducing embolic events through avoidance of electrode 1-to-10 interaction and by better tissue contact due to the 20° forward tilt. Although clinical data with this new array are lacking so far, the PVAC system has been shown to be a promising tool for PVI. However, prospective studies especially with the novel array are required to determine its true role for catheter ablation of atrial fibrillation in the future.

Entities:  

Mesh:

Year:  2014        PMID: 25070931     DOI: 10.1007/s00399-014-0330-x

Source DB:  PubMed          Journal:  Herzschrittmacherther Elektrophysiol        ISSN: 0938-7412


  18 in total

1.  Catheter ablation for paroxysmal atrial fibrillation: a randomized comparison between multielectrode catheter and point-by-point ablation.

Authors:  Alan Bulava; Jiří Haniš; David Sitek; Ondřej Ošmera; Dan Karpianus; Michal Snorek; Kateřina Rehoušková; František Toušek; Ladislav Pešl
Journal:  Pacing Clin Electrophysiol       Date:  2010-09       Impact factor: 1.976

2.  Microembolism and catheter ablation II: effects of cerebral microemboli injection in a canine model.

Authors:  David E Haines; Mark T Stewart; Noah D Barka; Nicole Kirchhof; Linnea R Lentz; Nicki M Reinking; Jon F Urban; Franck Halimi; Thomas Deneke; Emanuel Kanal
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-12-28

3.  Modified phased radiofrequency ablation of atrial fibrillation reduces the number of cerebral microembolic signals.

Authors:  Stephan Zellerhoff; Martin A Ritter; Simon Kochhäuser; Ralf Dittrich; Julia Köbe; Peter Milberg; Catharina Korsukewitz; Dirk G Dechering; Christian Pott; Kristina Wasmer; Patrick Leitz; Fatih Güner; Lars Eckardt; Gerold Mönnig
Journal:  Europace       Date:  2013-09-26       Impact factor: 5.214

4.  Randomized study comparing duty-cycled bipolar and unipolar radiofrequency with point-by-point ablation in pulmonary vein isolation.

Authors:  Alex Bittner; Gerold Mönnig; Stephan Zellerhoff; Christian Pott; Julia Köbe; Dirk Dechering; Peter Milberg; Kristina Wasmer; Lars Eckardt
Journal:  Heart Rhythm       Date:  2011-03-30       Impact factor: 6.343

5.  First report of phrenic nerve injury during pulmonary vein isolation using the Ablation Frontiers pulmonary vein ablation catheter.

Authors:  Syed Y Ahsan; Andrew S Flett; Pier D Lambiase; Oliver R Segal
Journal:  J Interv Card Electrophysiol       Date:  2010-10-13       Impact factor: 1.900

6.  Incidence and predictors of pulmonary vein stenosis following catheter ablation of atrial fibrillation using the anatomic pulmonary vein ablation approach: results from paired magnetic resonance imaging.

Authors:  Jun Dong; Chandrasekhar R Vasamreddy; Vinod Jayam; Darshan Dalal; Timm Dickfeld; Zayd Eldadah; Glenn Meininger; Henry R Halperin; Ronald Berger; David A Bluemke; Hugh Calkins
Journal:  J Cardiovasc Electrophysiol       Date:  2005-08

7.  Phased RF ablation in persistent atrial fibrillation.

Authors:  John Hummel; Gregory Michaud; Robert Hoyt; David DeLurgio; Abdi Rasekh; Fred Kusumoto; Michael Giudici; Dan Dan; David Tschopp; Hugh Calkins; Lucas Boersma
Journal:  Heart Rhythm       Date:  2013-11-14       Impact factor: 6.343

8.  Duty-cycled bipolar/unipolar radiofrequency ablation for symptomatic atrial fibrillation induces significant pulmonary vein narrowing at long-term follow-up.

Authors:  Marieke G Compier; Darryl P Leong; Nina Ajmone Marsan; Victoria Delgado; Katja Zeppenfeld; Martin J Schalij; Serge A Trines
Journal:  Europace       Date:  2013-01-22       Impact factor: 5.214

9.  Microembolism and catheter ablation I: a comparison of irrigated radiofrequency and multielectrode-phased radiofrequency catheter ablation of pulmonary vein ostia.

Authors:  David E Haines; Mark T Stewart; Sarah Dahlberg; Noah D Barka; Cathy Condie; Gary R Fiedler; Nicole A Kirchhof; Franck Halimi; Thomas Deneke
Journal:  Circ Arrhythm Electrophysiol       Date:  2013-02-07

10.  Does the number of simultaneously activated electrodes during phased RF multielectrode ablation of atrial fibrillation influence the incidence of silent cerebral microembolism?

Authors:  Marcus Wieczorek; Reinhard Hoeltgen; Martin Brueck
Journal:  Heart Rhythm       Date:  2013-04-06       Impact factor: 6.343

View more
  2 in total

1.  Ablation of atrial fibrillation: single-shot techniques poised to dominate rhythm control strategies/the future is here.

Authors:  Antonis S Manolis
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

2.  Clinical outcomes of AF patients treated with the first and second-generation of circular mapping and ablation catheter: insights from a real world multicenter experience.

Authors:  Giovanni Rovaris; Paolo De Filippo; Francesco Laurenzi; Gabriele Zanotto; Nicola Bottoni; Mattia Pozzi; Fabrizio Giofrè; Piergiuseppe De Girolamo; Emanuela Visentin; Elena Piazzi; Paola Ferrari
Journal:  J Interv Card Electrophysiol       Date:  2017-09-05       Impact factor: 1.900

  2 in total