Literature DB >> 20528997

Catheter ablation for paroxysmal atrial fibrillation: a randomized comparison between multielectrode catheter and point-by-point ablation.

Alan Bulava1, Jiří Haniš, David Sitek, Ondřej Ošmera, Dan Karpianus, Michal Snorek, Kateřina Rehoušková, František Toušek, Ladislav Pešl.   

Abstract

INTRODUCTION: Catheter ablation for paroxysmal atrial fibrillation is widely used for patients with drug-refractory paroxysms of arrhythmia. Recently, novel technologies have been introduced to the market that aim to simplify and shorten the procedure. AIM: To compare the clinical outcome of pulmonary vein (PV) isolation using a multipolar circular ablation catheter (PVAC group), with point-by-point PV isolation using an irrigated-tip ablation catheter and the CARTO mapping system (CARTO group; CARTO, Biosense Webster, Diamond Bar, CA, USA).
METHODS: Patients with documented PAF were randomized to undergo PV isolation using PVAC or CARTO. Atrial fibrillation (AF) recurrences were documented by serial 7-day Holter monitoring.
RESULTS: One hundred and two patients (mean age 58 ± 11 years, 68 men) were included in the study. The patients had comparable baseline clinical characteristics, including left atrial dimensions and left ventricular ejection fraction, in both study arms (PVAC: n = 51 and CARTO: n = 51). Total procedural and fluoroscopic times were significantly shorter in the PVAC group (107 ± 31 minutes vs 208 ± 46 minutes, P < 0.0001 and 16 ± 5 minutes vs 28 ± 8 minutes, P < 0.0001, respectively). The AF recurrence was documented in 23% and 29% of patients in the PVAC and CARTO groups, respectively (P = 0.8), during the mean follow-up of 200 ± 13 days. No serious complications were noted in both study groups.
CONCLUSIONS: Clinical success rates of PV isolation are similar when using multipolar circular PV ablation catheter and point-by-point ablation with a three-dimensional (3D) navigation system in patients with PAF, and results in shorter procedural and fluoroscopic times with a comparable safety profile. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20528997     DOI: 10.1111/j.1540-8159.2010.02807.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  25 in total

1.  Point-by-point pulmonary vein antrum isolation guided by intracardiac echocardiography and 3D mapping and duty-cycled multipolar AF ablation: effect of multipolar ablation on procedure duration and fluoroscopy time.

Authors:  Yaariv Khaykin; Lauren Zarnett; Daniel Friedlander; Zaev A Wulffhart; Bonnie Whaley; David Giewercer; Bernice Tsang; Atul Verma
Journal:  J Interv Card Electrophysiol       Date:  2012-03-11       Impact factor: 1.900

2.  Phased multipolar radiofrequency pulmonary vein isolation is as effective and safe as conventional irrigated point-to-point ablation. A prospective randomised 1-year implantable cardiac monitoring device follow-up trial.

Authors:  S J Podd; A N Sulke; C Sugihara; S S Furniss
Journal:  J Interv Card Electrophysiol       Date:  2015-08-27       Impact factor: 1.900

Review 3.  Multi-Electrode Ablation Catheters for AF Ablation: Effective Reality or Elegant Experiment?

Authors:  Lucas Boersma
Journal:  J Atr Fibrillation       Date:  2012-06-15

Review 4.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  J Interv Card Electrophysiol       Date:  2012-03       Impact factor: 1.900

Review 5.  Multielectrode Pulmonary Vein Ablation Catheter (PVAC(®)): current data on results and risks.

Authors:  Gerold Mönnig; Lars Eckardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2014-12

Review 6.  Recent Advances in Lesion Formation for Catheter Ablation of Atrial Fibrillation.

Authors:  Adam S Barnett; Tristram D Bahnson; Jonathan P Piccini
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-05

Review 7.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

Review 8.  Comparison of the Efficacy of PVAC® and nMARQ for paroxysmal atrial fibrillation.

Authors:  Avishag Laish-Farkash; Mahmoud Suleiman
Journal:  J Atr Fibrillation       Date:  2017-04-30

9.  Clinical outcomes of AF patients treated with the first and second-generation of circular mapping and ablation catheter: insights from a real world multicenter experience.

Authors:  Giovanni Rovaris; Paolo De Filippo; Francesco Laurenzi; Gabriele Zanotto; Nicola Bottoni; Mattia Pozzi; Fabrizio Giofrè; Piergiuseppe De Girolamo; Emanuela Visentin; Elena Piazzi; Paola Ferrari
Journal:  J Interv Card Electrophysiol       Date:  2017-09-05       Impact factor: 1.900

10.  Long-term outcomes (>2 years) of atrial fibrillation ablation using a multi-electrode ablation catheter in patients with paroxysmal atrial fibrillation.

Authors:  Khang-Li Looi; Parag Gajendragadkar; Tamer Taha; Maros Elsik; Elizabeth Scully; Patrick Heck; Simon Fynn; Munmohan Virdee; David Begley
Journal:  J Interv Card Electrophysiol       Date:  2012-10-25       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.