Literature DB >> 25070013

Tidal volumes in spontaneously breathing preterm infants supported with continuous positive airway pressure.

Qaasim N Mian1, Gerhard Pichler2, Corinna Binder3, Megan O'Reilly1, Khalid Aziz1, Berndt Urlesberger3, Po-Yin Cheung1, Georg M Schmölzer2.   

Abstract

OBJECTIVE: To describe changes in tidal volume (VT) and their correlation to changes in oxygen saturation and heart rate in spontaneously breathing preterm infants immediately after birth. STUDY
DESIGN: In this prospective observational, 2-center study, a flow sensor was attached to the facemask of spontaneously breathing infants born at <37 weeks' gestational age who received continuous positive airway pressure (CPAP) immediately after birth. Respiratory function, heart rate, and oxygen saturation were continuously recorded during spontaneous breathing.
RESULTS: Fifty-five infants (mean [SD] gestational age 31 [26-36] weeks and birth weight 1647 [500] g) received mask CPAP in the delivery room. CPAP was started at a median (IQR) 90 (60-118) seconds after birth and was delivered for 720 (300-900) seconds. Median VT ranged between 4.2 and 5.8 mL/kg with the individual VT varied between 0.9 and 19.8 mL/kg. Overall, VT increased over the first few minutes after birth and decreased thereafter. The increase in saturation after birth lagged behind the published normal ranges for spontaneously breathing preterm infants without CPAP.
CONCLUSIONS: The 50th percentile for spontaneous VT in preterm infants during mask CPAP ranged from 4.2 to 5.8 mL/kg, with wide individual variation observed in the first minutes after birth. Preterm infants requiring CPAP after birth may take longer to achieve so-called "normal" saturation targets.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25070013     DOI: 10.1016/j.jpeds.2014.06.047

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  7 in total

Review 1.  Essentials for aerosol delivery to term and pre-term infants.

Authors:  Andrew R Clark
Journal:  Ann Transl Med       Date:  2021-04

2.  The DELUX study: development of lung volumes during extubation of preterm infants.

Authors:  Leonie Plastina; Vincent D Gaertner; Andreas D Waldmann; Janine Thomann; Dirk Bassler; Christoph M Rüegger
Journal:  Pediatr Res       Date:  2021-08-31       Impact factor: 3.953

3.  Accuracy of currently available neonatal respiratory function monitors for neonatal resuscitation.

Authors:  Charlotte Verbeek; Henriëtte A van Zanten; Jeroen J van Vonderen; Marcus J Kitchen; Stuart B Hooper; Arjan B Te Pas
Journal:  Eur J Pediatr       Date:  2016-06-08       Impact factor: 3.183

4.  Predictors of death including quality of positive pressure ventilation during newborn resuscitation and the relationship to outcome at seven days in a rural Tanzanian hospital.

Authors:  Robert Moshiro; Jeffrey M Perlman; Hussein Kidanto; Jan Terje Kvaløy; Paschal Mdoe; Hege L Ersdal
Journal:  PLoS One       Date:  2018-08-17       Impact factor: 3.240

5.  A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin.

Authors:  Anne Lee Solevåg; Enrico Haemmerle; Sylvia van Os; Katinka P Bach; Po-Yin Cheung; Georg M Schmölzer
Journal:  Front Pediatr       Date:  2016-11-28       Impact factor: 3.418

Review 6.  Delivery room interventions to prevent bronchopulmonary dysplasia in extremely preterm infants.

Authors:  E E Foglia; E A Jensen; H Kirpalani
Journal:  J Perinatol       Date:  2017-06-01       Impact factor: 2.521

Review 7.  Reducing Brain Injury of Preterm Infants in the Delivery Room.

Authors:  Francesca Viaroli; Po-Yin Cheung; Megan O'Reilly; Graeme R Polglase; Gerhard Pichler; Georg M Schmölzer
Journal:  Front Pediatr       Date:  2018-10-16       Impact factor: 3.418

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.