Literature DB >> 25069938

Cutting efficiency of Reciproc and waveOne reciprocating instruments.

Gianluca Plotino1, Alessio Giansiracusa Rubini2, Nicola M Grande2, Luca Testarelli2, Gianluca Gambarini2.   

Abstract

INTRODUCTION: The aim of the present study was to evaluate the cutting efficiency of 2 new reciprocating instruments, Reciproc and WaveOne.
METHODS: Twenty-four new Reciproc R25 and 24 new WaveOne Primary files were activated by using a torque-controlled motor (Silver Reciproc) and divided into 4 groups (n = 12): group 1, Reciproc activated by Reciproc ALL program; group 2, Reciproc activated by WaveOne ALL program; group 3, WaveOne activated by Reciproc ALL program; and group 4, WaveOne activated by WaveOne ALL program. The device used for the cutting test consisted of a main frame to which a mobile plastic support for the handpiece is connected and a stainless steel block containing a Plexiglas block (inPlexiglass, Rome, Italy) against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1 mm. Means and standard deviations of each group were calculated, and data were statistically analyzed with 1-way analysis of variance and Bonferroni test (P < .05).
RESULTS: Reciproc R25 displayed greater cutting efficiency than WaveOne Primary for both the movements used (P < .05); in particular, Reciproc instruments used with their proper reciprocating motion presented a statistically significant higher cutting efficiency than WaveOne instruments used with their proper reciprocating motion (P < .05). There was no statistically significant difference between the 2 movements for both instruments (P > .05).
CONCLUSIONS: Reciproc instruments demonstrated statistically higher cutting efficiency than WaveOne instruments.
Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cutting efficiency; NiTi instruments; cutting test; reciprocation

Mesh:

Substances:

Year:  2014        PMID: 25069938     DOI: 10.1016/j.joen.2014.01.041

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  17 in total

1.  Effects of different lasers on organic/inorganic ratio of radicular dentin.

Authors:  F C Lopes; R Roperto; A Akkus; O Akkus; A E Souza-Gabriel; M D Sousa-Neto
Journal:  Lasers Med Sci       Date:  2016-01-21       Impact factor: 3.161

2.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

3.  Surface deformation of several nickel-titanium rotary instruments after removal of the root canal filling materials: a scanning electron microscope evaluation.

Authors:  Taha Özyürek; Ebru Özsezer Demiryürek
Journal:  Odontology       Date:  2019-09-17       Impact factor: 2.634

4.  A comparative study of mechanical resistance of two reciprocating files.

Authors:  Dario Di Nardo; Massimo Galli; Antonio Morese; Marco Seracchiani; Valerio Ferri; Gabriele Miccoli; Gianluca Gambarini; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-03-01

5.  In vitro resistance to fracture of two nickel-titanium rotary instruments made with different thermal treatments.

Authors:  Gabriele Miccoli; Gianfranco Gaimari; Marco Seracchiani; Antonio Morese; Tatyana Khrenova; Dario Di Nardo
Journal:  Ann Stomatol (Roma)       Date:  2017-11-08

6.  Root canal shaping of curved canals by Reciproc Blue system and Pro Taper Gold: A micro-computed tomographic study.

Authors:  Rogério-Vieira Silva; Murilo-Priori Alcalde; Martinho-Campolina-Ribeiro Horta; Clarissa-Teles Rodrigues; Frank-Ferreira Silveira; Marco-Antônio Duarte; Eduardo Nunes
Journal:  J Clin Exp Dent       Date:  2021-02-01

7.  Cutting efficiency of instruments with different movements: a comparative study.

Authors:  Luigi Tocci; Gianluca Plotino; Dina Al-Sudani; Alessio Giansiracusa Rubini; Gianpaolo Sannino; Lucila Piasecki; Ermanno Putortì; Luca Testarelli; Gianluca Gambarini
Journal:  J Oral Maxillofac Res       Date:  2015-03-30

Review 8.  Single file reciprocating systems: A systematic review and meta-analysis of the literature: Comparison of reciproc and WaveOne.

Authors:  Rana Alsilani; Fatima Jadu; Dania F Bogari; Ahmed M Jan; Turki Y Alhazzazi
Journal:  J Int Soc Prev Community Dent       Date:  2016-10-24

9.  A comparison of the shaping ability of three nickel-titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro.

Authors:  Zhao Wei; Zhi Cui; Ping Yan; Han Jiang
Journal:  BMC Oral Health       Date:  2017-01-09       Impact factor: 2.757

10.  Influence of reuse and cervical preflaring on the fracture strength of reciprocating instruments.

Authors:  Claudio Maniglia-Ferreira; Fabio de Almeida Gomes; Tatyana Ximenes; Murilo Alves Teixeira Neto; Thiane Elys Arruda; Giovani Gonçalves Ribamar; Luis Flávio Gaspar Herculano
Journal:  Eur J Dent       Date:  2017 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.