Abstract
Ordinal-scale strength assessment methods currently used in Paralympic athletics classification prevent the development of evidence-based classification systems. This study evaluated a battery of 7, ratio-scale, isometric tests with the aim of facilitating the development of evidence-based methods of classification. This study aimed to report sex-specific normal performance ranges, evaluate test-retest reliability, and evaluate the relationship between the measures and body mass.Body mass and strength measures were obtained from 118 participants-63 males and 55 females-ages 23.2 years ± 3.7 (mean ± SD). Seventeen participants completed the battery twice to evaluate test-retest reliability. The body mass-strength relationship was evaluated using Pearson correlations and allometric exponents.Conventional patterns of force production were observed. Reliability was acceptable (mean intraclass correlation = 0.85). Eight measures had moderate significant correlations with body size (r = 0.30-61). Allometric exponents were higher in males than in females (mean 0.99 vs 0.30).Results indicate that this comprehensive and parsimonious battery is an important methodological advance because it has psychometric properties critical for the development of evidence-based classification. Measures were interrelated with body size, indicating further research is required to determine whether raw measures require normalization in order to be validly applied in classification.Entities:
Mesh:
Year: 2014 PMID: 25068950 PMCID: PMC4602423 DOI: 10.1097/MD.0000000000000031
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.889
Strength and Body Size Test Protocols
FIGURE 1Panel A shows the rigid aluminum frame in which the strength tests were conducted. The arrow indicates the ability of the chair to move in the fore-aft direction. Panel B shows a magnified view of the load cell set up with arrows indicating the ability to move the load cell vertically and horizontally.
FIGURE 2Panel A illustrates the position that participants were placed into for the bilateral Supported arm push. Panel B illustrates the position that participants were placed into for the leg extensor strength test.
Descriptive Statistics for Body Mass and Strength Measure
Test–Retest Reliability of Novel Strength Measures (n = 17)
Pearson Correlations and Allometric Scaling for Body Mass and Strength Measures