Literature DB >> 25062132

The relationship between tear meniscus regularity and conjunctival folds.

Stefan Bandlitz1, Christine Purslow, Paul J Murphy, Heiko Pult.   

Abstract

PURPOSE: To investigate the capability of a new portable digital meniscometer (PDM) to measure tear meniscus radius (TMR) and tear meniscus height (TMH) at different locations along the lower lid and to evaluate relationships between tear meniscus regularity and the degree of lid-parallel conjunctival folds (LIPCOFs).
METHODS: Using the PDM, the TMR and TMH of 42 subjects were measured at three locations along the lower lid of one eye: central, perpendicularly below the pupil center (TMR-C, TMH-C), and temporal (TMR-T, TMH-T) and nasal (TMR-N, TMH-N), perpendicularly below the limbus. Nasal and temporal LIPCOF grades were recorded. Correlations between the measurements were analyzed using the Pearson coefficient (or Spearman rank in nonparametric data), and the differences were evaluated by paired t tests or analysis of variance and post hoc Fisher least significant difference test.
RESULTS: Temporal TMR was 0.041 mm flatter (p = 0.002) and TMH-T was 0.063 mm higher (p < 0.001), whereas TMR-N was 0.026 mm flatter (p = 0.038) and TMH-N was 0.046 mm higher (p < 0.001) than TMR-C and TMH-C. Temporal LIPCOF grades were significantly correlated to temporal alterations in TMH (r = 0.590; p < 0.001) and TMR (r = 0.530; p < 0.001), and nasal LIPCOF grades were significantly correlated to nasal alterations in TMH (r = 0.492; p = 0.001) and TMR (r = 0.350; p = 0.023).
CONCLUSIONS: The PDM is able to noninvasively detect significant differences in TMR and TMH along the lower lid. The flatter TMR and higher TMH at the nasal and temporal locations are associated with increased LIPCOF. Because increased LIPCOF scores may affect tear film disruption along the lower lid, measuring TMR and TMH at the central position below the pupil may provide the best intersubject reliability.

Entities:  

Mesh:

Year:  2014        PMID: 25062132     DOI: 10.1097/OPX.0000000000000358

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  2 in total

1.  Usability and reproducibility of tear meniscus values generated via swept-source optical coherence tomography and the slit lamp with a graticule method.

Authors:  Hitoshi Imamura; Hitoshi Tabuchi; Shunsuke Nakakura; Daisuke Nagasato; Hiroaki Baba; Yoshiaki Kiuchi
Journal:  Int Ophthalmol       Date:  2017-04-09       Impact factor: 2.031

2.  Advances in Dry Eye Disease Examination Techniques.

Authors:  Yaying Wu; Chunyang Wang; Xin Wang; Yujie Mou; Kelan Yuan; Xiaodan Huang; Xiuming Jin
Journal:  Front Med (Lausanne)       Date:  2022-01-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.