Literature DB >> 25059995

[Quality of vision studied by comparative measurement of light scattering].

V Rzemyk1, B Cochener2.   

Abstract

PURPOSE: To assess quality of vision by measuring ocular light scattering with two platforms and comparing them to traditional tests, in healthy subjects and cataract patients. PATIENTS AND METHODS: One hundred and sixty-eight eyes divided in two groups were examined by the same clinician in a prospective study (group 1, healthy controls, with a mean age of 31.22 [± 6.76]; and group 2, patients presenting with cataract, with a mean age of 60.36 [± 10.27]). Patients with ocular surface disease were excluded from this study. Each group responded to the VF-14 questionnaire, underwent an examination with lens opacities assessed by LOCS III and a measurement of ocular light scattering with two platforms: the OQAS (Visiometrics(©)) and the C-Quant (Oculus(©)). We analyzed correlations between indices of light scattering with the two platforms (respectively OSI and log(s)) and traditional quality of vision tests (VF-14 questionnaire and LOCS III).
RESULTS: Strong correlations were found between the OSI and LOCS III. Moderate correlations were found between the OSI and the VF-14 questionnaire, as well as between log(s), VF-14 questionnaire and LOCS III.
CONCLUSION: Indices of light scattering seems to be valid tools to assess quality of vision, thus lending themselves to routine testing of visual function.
Copyright © 2014 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  C-Quant; Cataract; Cataracte; Diffusion de lumière; Light scatter; OQAS; Quality of vision; Qualité de vision; Stray light

Mesh:

Year:  2014        PMID: 25059995     DOI: 10.1016/j.jfo.2014.01.006

Source DB:  PubMed          Journal:  J Fr Ophtalmol        ISSN: 0181-5512            Impact factor:   0.818


  3 in total

1.  Comparison of pseudophakic retinal straylight in spherical/aspherical and hydrophobic/hydrophilic intraocular lens.

Authors:  Yong Tang; Hui Song; Jing Chen; Xin Tang
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

2.  The assessment of the impact of glistening on visual performance in relation to tear film quality.

Authors:  Amanda Argay; Peter Vamosi
Journal:  PLoS One       Date:  2020-10-12       Impact factor: 3.240

3.  Using Optical Quality Analysis System for predicting surgical parameters in age-related cataract patients.

Authors:  Thibaud Garcin; Damien Grivet; Gilles Thuret; Philippe Gain
Journal:  PLoS One       Date:  2020-10-12       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.