Literature DB >> 25059701

Effect of the CT table strap on radiation exposure and image quality during cervical spine CT.

P G Kranz1, J D Wylie2, J K Hoang3, A S Kosinski4.   

Abstract

BACKGROUND AND
PURPOSE: The CT table strap may impair shoulder lowering during cervical spine CT. The purpose of this investigation was to evaluate the effect of the CT table strap on radiation exposure and image quality during CT of the cervical spine.
MATERIALS AND METHODS: Patients undergoing cervical spine CT were prospectively randomized to having the CT table strap placed around the torso and arms (control group) or around the torso only (intervention group). Radiation exposure, shoulder position, and image quality were evaluated. Potential confounders, including neck diameter and scan length, were also assessed.
RESULTS: Fifty-eight patients were enrolled and randomized, and 51 subjects were included in the final study population. There was a 21% decrease in radiation exposure in the intervention group compared with the control group (mean dose-length product, 540 ± 152 versus 686 ± 200 mGy × cm, P = .005). Subjects in the intervention group achieved shoulder lowering of an average of >1 vertebral body lower than the control group (mean shoulder level, 7.7 ± 1.3 versus 6.5 ± 1.3, P = .001). Subjective image quality, determined by the lowest level of spinal cord visibility, was also better in the intervention group (mean cord visibility level, 6.9 ± 1.3 versus 5.9 ± 1.3, P = .006). No differences in neck diameter (P = .28) or scan length (P = .55) were observed between groups.
CONCLUSIONS: The CT table strap inhibits shoulder lowering during CT of the cervical spine. Placement of the patient's arms outside the CT table strap results in decreased radiation exposure and increased image quality compared with patients whose arms are placed inside the strap.
© 2014 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2014        PMID: 25059701      PMCID: PMC7966249          DOI: 10.3174/ajnr.A4074

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  12 in total

1.  Correlation of cross-sectional diameter with image quality and radiation exposure in MDCT examinations of the neck.

Authors:  Jenny K Hoang; Andreia R Gafton; James D Eastwood; Luke F Chen; Lynne M Hurwitz
Journal:  AJR Am J Roentgenol       Date:  2011-11       Impact factor: 3.959

2.  The Image Gently campaign: working together to change practice.

Authors:  Marilyn J Goske; Kimberly E Applegate; Jennifer Boylan; Priscilla F Butler; Michael J Callahan; Brian D Coley; Shawn Farley; Donald P Frush; Marta Hernanz-Schulman; Diego Jaramillo; Neil D Johnson; Sue C Kaste; Greg Morrison; Keith J Strauss; Nora Tuggle
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

Review 3.  CT radiation dose: current controversies and dose reduction strategies.

Authors:  Justin E Costello; Nathan D Cecava; Jonathan E Tucker; Jennifer L Bau
Journal:  AJR Am J Roentgenol       Date:  2013-12       Impact factor: 3.959

4.  CT dose index and patient dose: they are not the same thing.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Dianna D Cody; John M Boone; Michael F McNitt-Gray
Journal:  Radiology       Date:  2011-05       Impact factor: 11.105

Review 5.  Optimal tube potential for radiation dose reduction in pediatric CT: principles, clinical implementations, and pitfalls.

Authors:  Lifeng Yu; Michael R Bruesewitz; Kristen B Thomas; Joel G Fletcher; James M Kofler; Cynthia H McCollough
Journal:  Radiographics       Date:  2011 May-Jun       Impact factor: 5.333

Review 6.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

7.  Investigation of American Association of Physicists in Medicine Report 204 size-specific dose estimates for pediatric CT implementation.

Authors:  Samuel L Brady; Robert A Kaufman
Journal:  Radiology       Date:  2012-10-23       Impact factor: 11.105

8.  Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study.

Authors:  Amy K Hara; Robert G Paden; Alvin C Silva; Jennifer L Kujak; Holly J Lawder; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2009-09       Impact factor: 3.959

9.  Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study.

Authors:  Sebastian T Schindera; Rendon C Nelson; Thomas L Toth; Giao T Nguyen; Greta I Toncheva; David M DeLong; Terry T Yoshizumi
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

10.  Arm raising at exposure-controlled multidetector trauma CT of thoracoabdominal region: higher image quality, lower radiation dose.

Authors:  Monique Brink; Frank de Lange; Luuk J Oostveen; Helena M Dekker; Digna R Kool; Jaap Deunk; Michael J R Edwards; Cornelis van Kuijk; Richard L Kamman; Johan G Blickman
Journal:  Radiology       Date:  2008-11       Impact factor: 11.105

View more
  2 in total

1.  Systematic Radiation Dose Reduction in Cervical Spine CT of Human Cadaveric Specimens: How Low Can We Go?

Authors:  M Tozakidou; C Reisinger; D Harder; J Lieb; Z Szucs-Farkas; M Müller-Gerbl; U Studler; S Schindera; A Hirschmann
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-21       Impact factor: 3.825

Review 2.  2021 Korean Thyroid Imaging Reporting and Data System and Imaging-Based Management of Thyroid Nodules: Korean Society of Thyroid Radiology Consensus Statement and Recommendations.

Authors:  Eun Ju Ha; Sae Rom Chung; Dong Gyu Na; Hye Shin Ahn; Jin Chung; Ji Ye Lee; Jeong Seon Park; Roh-Eul Yoo; Jung Hwan Baek; Sun Mi Baek; Seong Whi Cho; Yoon Jung Choi; Soo Yeon Hahn; So Lyung Jung; Ji-Hoon Kim; Seul Kee Kim; Soo Jin Kim; Chang Yoon Lee; Ho Kyu Lee; Jeong Hyun Lee; Young Hen Lee; Hyun Kyung Lim; Jung Hee Shin; Jung Suk Sim; Jin Young Sung; Jung Hyun Yoon; Miyoung Choi
Journal:  Korean J Radiol       Date:  2021-10-26       Impact factor: 3.500

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.