Literature DB >> 25058937

An electrochemical immunosensor for ultrasensitive detection of carbohydrate antigen 199 based on Au@Cu(x)OS yolk-shell nanostructures with porous shells as labels.

Aiping Guo1, Yueyun Li2, Wei Cao1, Xianchao Meng1, Dan Wu1, Qin Wei3, Bin Du1.   

Abstract

A novel and sensitive electrochemical immunosensor for ultrasensitive detection of pancreatic cancer biomarker carbohydrate antigen 199 (CA199) was proposed by using Au@Cu(x)OS yolk-shell nanostructures with porous shells as labels for signal amplification. Au@Cu(x)OS yolk-shell nanostructures exhibit high electrocatalytic activity toward the reduction of hydrogen peroxide (H2O2) as analytical signal. Moreover, secondary antibody (Ab2) can adsorb on the surface of Au@Cu(x)OS with porous shells which has large surface area and could greatly increase the probability of Ab2-antigen interactions thereby leading to higher sensitivity. Reduced graphene oxide-tetraethylene pentamine (rGO-TEPA), containing abundant amine groups, was supported Au nanoparticles as a support platform to immobilize the primary antibody (Ab1). The resulting sensing interface of rGO-TEPA/AuNPs could provide a large electroconductive surface area, allowing high loadings of the biological recognition elements as well as the occurrence of electrocatalytic and electron-transfer processes. Under optimal conditions, the immunosensor exhibited a wide linear response to CA199 ranging from 0.001 to 12 U/mL with a low detection limit of 0.0005 U/mL. The designed immunosensor displayed good precision, high sensitivity, acceptable stability and reproducibility, and has been applied to the analysis of serum with satisfactory results. The proposed method provides a new promising platform of clinical immunoassay for other biomolecules.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Au nanoparticles; Au@Cu(x)OS yolk–shell nanostructures with porous shells; Pancreatic cancer biomarker CA199; Reduced graphene oxide–tetraethylene pentamine (rGO–TEPA)

Mesh:

Substances:

Year:  2014        PMID: 25058937     DOI: 10.1016/j.bios.2014.07.017

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

Review 1.  Electrochemical biosensors for measurement of colorectal cancer biomarkers.

Authors:  Wenxian Zhang; Guangchun Xiao; Jun Chen; Li Wang; Qiongzheng Hu; Jian Wu; Wenhong Zhang; Ming Song; Jinwei Qiao; Chonghai Xu
Journal:  Anal Bioanal Chem       Date:  2021-03-05       Impact factor: 4.142

2.  A Novel Point-of-Care Biomarker Recognition Method: Validation by Detecting Marker for Diabetic Nephropathy.

Authors:  Sahana Pentyala; John Muller; Thomas Tumillo; Avijit Roy; Pooja Mysore; Srinivas Pentyala
Journal:  Diagnostics (Basel)       Date:  2015-04-23
  2 in total