Literature DB >> 25048986

Data extraction and reporting strategies of studies assessing non-central corneal thickness by Pentacam: a review.

Sven Jonuscheit1.   

Abstract

PURPOSE: To review data extraction strategies for the reporting of non-central corneal thickness with the Pentacam system.
METHODS: Using predefined search terms, the electronic National Institutes of Health database (PubMed) was searched for studies assessing non-central corneal thickness using the Pentacam instrument. The article titles of the search results were screened for relevance. The abstracts of papers with appropriate titles were retrieved and read. Articles with relevant abstracts were obtained and read in full. The reference list of each article was hand searched to identify further studies. Articles reporting central corneal thickness only were excluded.
RESULTS: Seventeen peer-reviewed studies were identified. Considerable differences in data extraction and reporting of non-central corneal thickness were noted, with non-central pachymetry being assessed at locations between 1.5 and 5.0mm away from the centre. The terminology used to describe non-central pachymetry was inconsistent. Ring-averaged and single point pachymetry data have been reported. Ring-averaged pachymetry may obscure considerable regional variability in corneal thickness.
CONCLUSIONS: The use of different data extraction and reporting strategies can obscure regional corneal thickness asymmetries. This may influence the monitoring of corneal crosslinking outcomes, the interpretation of corneal swelling in contact lens studies and the clinical decision-making in preoperative assessments of refractive surgery patients. For the reliable identification of regional corneal thickness variations point-pachymetry data appears to be preferable over ring-averaged pachymetry.
Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Data extraction; Non-central corneal thickness; Pentacam; Peripheral corneal thickness

Mesh:

Year:  2014        PMID: 25048986     DOI: 10.1016/j.clae.2014.06.004

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  3 in total

1.  Using the posterior to anterior corneal curvature radii ratio to minimize the risk of a postoperative hyperopic shift after Descemet membrane endothelial keratoplasty.

Authors:  Raphael Diener; Nicole Eter; Maged Alnawaiseh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-31       Impact factor: 3.117

2.  Accommodation response and spherical aberration during orthokeratology.

Authors:  L Batres; S Peruzzo; M Serramito; G Carracedo
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-11-12       Impact factor: 3.117

3.  The role of peripheral ocular length and peripheral corneal radius of curvature in determining refractive error.

Authors:  Saleh H A Alhussain; Edward A H Mallen; Niall C Strang; Sven Jonuscheit
Journal:  J Optom       Date:  2021-04-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.