Literature DB >> 25033728

Contrast-enhanced postmortem computed tomography in clinical pathology: enhanced value of 20 clinical autopsies.

Saskia E Westphal1, Jonas C Apitzsch2, Tobias Penzkofer3, Christiane K Kuhl4, Andreas H Mahnken2, Ruth Knüchel5.   

Abstract

Postmortem computed tomography (PMCT) is a modern tool that complements autopsy diagnostics. In clinical autopsies, a major cause of death is cardiovascular disease. To improve the performance of PMCT in cardiovascular disease, full body angiography was developed (PMCT angiography [PMCTA]). Twenty PMCTA scans generated before autopsy were compared with native PMCT and clinical autopsy. The objective of the study was to quantify the additional diagnostic value of adding angiography to native imaging and to compare PMCT and PMCTA findings to autopsy findings. The diagnosis of the cause of death was identical or overlapped in 80% of the cases that used PMCTA and 70% that used PMCT. The additional diagnostic yield given by PMCT and PMCTA in combination with autopsy was 55%. PMCT yielded additional diagnoses in the musculoskeletal system. The greatest additional diagnostic value of PMCTA was in association with cardiovascular diagnoses. The accuracy of PMCTA for cardiac causes of death was 80%, and the positive predictive value was 90%. The findings indicate that native PMCT cannot display the cardiovascular system sufficiently clearly for high-quality diagnostic assessment. However, PMCTA is a powerful tool in autopsy cases with a history of cardiovascular disease and/or a suspected cardiovascular cause of death. The combination of PMCTA and clinical autopsy enhances diagnostic quality and completeness of the autopsy report. Furthermore, in cases without consent or with a restricted consent for clinical autopsy, PMCTA has the potential to provide information on cardiovascular causes of death.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Necropsy; PMCT; PMCTA; Postmortem angiography; Virtual autopsy

Mesh:

Year:  2014        PMID: 25033728     DOI: 10.1016/j.humpath.2014.05.007

Source DB:  PubMed          Journal:  Hum Pathol        ISSN: 0046-8177            Impact factor:   3.466


  7 in total

1.  Accuracy of non-contrast PMCT for determining cause of death.

Authors:  Garyfalia Ampanozi; Yannick A Thali; Wolf Schweitzer; Gary M Hatch; Lars C Ebert; Michael J Thali; Thomas D Ruder
Journal:  Forensic Sci Med Pathol       Date:  2017-06-15       Impact factor: 2.007

Review 2.  [Postmortem imaging procedures : Experiences and perspectives].

Authors:  S von Stillfried; P Isfort; R Knüchel-Clarke
Journal:  Pathologe       Date:  2017-09       Impact factor: 1.011

3.  Postmortem imaging findings and cause of death determination compared with autopsy: a systematic review of diagnostic test accuracy and meta-analysis.

Authors:  Garyfalia Ampanozi; Delaja Halbheer; Lars C Ebert; Michael J Thali; Ulrike Held
Journal:  Int J Legal Med       Date:  2019-08-27       Impact factor: 2.686

4.  Postmortem CT is more accurate than clinical diagnosis for identifying the immediate cause of death in hospitalized patients: a prospective autopsy-based study.

Authors:  Kunihiro Inai; Sakon Noriki; Kazuyuki Kinoshita; Toyohiko Sakai; Hirohiko Kimura; Akihiko Nishijima; Hiromichi Iwasaki; Hironobu Naiki
Journal:  Virchows Arch       Date:  2016-04-16       Impact factor: 4.064

Review 5.  Ultrasound in legal medicine-a missed opportunity or simply too late? A narrative review of ultrasonic applications in forensic contexts.

Authors:  Dustin Möbius; Antonia Fitzek; Niels Hammer; Axel Heinemann; Alexandra Ron; Julia Schädler; Johann Zwirner; Benjamin Ondruschka
Journal:  Int J Legal Med       Date:  2021-07-22       Impact factor: 2.686

6.  Investigation of medical intervention with fatal outcome: the impact of post-mortem CT and CT angiography.

Authors:  Axel Heinemann; Hermann Vogel; Martin Heller; Antonios Tzikas; Klaus Püschel
Journal:  Radiol Med       Date:  2015-08-19       Impact factor: 3.469

7.  Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

Authors:  Silke Grabherr; Axel Heinemann; Hermann Vogel; Guy Rutty; Bruno Morgan; Krzysztof Woźniak; Fabrice Dedouit; Florian Fischer; Stefanie Lochner; Holger Wittig; Giuseppe Guglielmi; Franziska Eplinius; Katarzyna Michaud; Cristian Palmiere; Christine Chevallier; Patrice Mangin; Jochen M Grimm
Journal:  Radiology       Date:  2018-05-01       Impact factor: 11.105

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.