Literature DB >> 25029465

Reliability of Intra-articular Rotational Axes at Standard Tibial Resection Level and Effect of Resecting Distally.

Yoshvin Sunnassee1, Henghui Zhang1, Edward P Southern2, Yi Wang1, Yuhui Shen1.   

Abstract

We determine the most reliable tibial intra-articular axis for rotational alignment of the tibial component at the standard resection level and at a distal resection level. The angles between the surgical transepicondylar axis and posterior condylar line, perpendicular to Akagi line, tibial anterior condylar line (ACL), and tibial maximum mediolateral line were measured at the standard resection level and 5 mm distal to the standard resection level. All axes exhibited relatively large standard deviations and ranges at the standard and distal resection level. t-test showed that there was a statistically significant difference (p < 0.05) for all the axes between the two resection levels, while only ACL showed a statistically significant difference (p = 0.047) with the equality of variance F-test. Akagi line exhibited good interobserver and intraobserver reliabilities but must be used with caution. Intra-articular axes are not reliable for tibial component alignment. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Mesh:

Year:  2014        PMID: 25029465     DOI: 10.1055/s-0034-1378193

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  3 in total

1.  Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis.

Authors:  Reha N Tandogan; Nanne P Kort; Ersin Ercin; Floris van Rooij; Luca Nover; Mo Saffarini; Michael T Hirschmann; Roland Becker; David Dejour
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-03-01       Impact factor: 4.114

2.  Gender differences affect the location of the patellar tendon attachment site for tibial rotational alignment in total knee arthroplasty.

Authors:  Le-Shu Zhang; Jin-Cheng Zhang; Hang Zhou; Qiang Zhang; Xiang-Yang Chen; Shuo Feng
Journal:  J Orthop Surg Res       Date:  2022-07-26       Impact factor: 2.677

3.  Patient-specific instrumentation for total knee arthroplasty improves reproducibility in the planned rotational positioning of the tibial component.

Authors:  Masaichi Sotozawa; Ken Kumagai; Shunsuke Yamada; Shuntaro Nejima; Yutaka Inaba
Journal:  J Orthop Surg Res       Date:  2022-09-05       Impact factor: 2.677