Literature DB >> 25026640

Grafting hyaluronic acid onto gold surface to achieve low protein fouling in surface plasmon resonance biosensors.

Xia Liu1, Renliang Huang, Rongxin Su, Wei Qi, Libing Wang, Zhimin He.   

Abstract

Antifouling surfaces capable of reducing nonspecific protein adsorption from natural complex media are highly desirable in surface plasmon resonance (SPR) biosensors. A new protein-resistant surface made through the chemical grafting of easily available hyaluronic acid (HA) onto gold (Au) substrate demonstrates excellent antifouling performance against protein adsorption. AFM images showed the uniform HA layer with a thickness of ∼10.5 nm on the Au surface. The water contact angles of Au surfaces decreased from 103° to 12° with the covalent attachment of a carboxylated HA matrix, indicating its high hydrophilicity mainly resulted from carboxyl and amide groups in the HA chains. Using SPR spectroscopy to investigate nonspecific adsorption from single protein solutions (bovine serum albumin (BSA), lysozyme) and complex media (soybean milk, cow milk, orange juice) to an HA matrix, it was found that ultralow or low protein adsorptions of 0.6-16.1 ng/cm(2) (e.g., soybean milk: 0.6 ng/cm(2)) were achieved on HA-Au surfaces. Moreover, anti-BSA was chosen as a model recognition molecule to characterize the immobilization capacity and the antifouling performance of anti-BSA/HA surfaces. The results showed that anti-BSA/HA sensor surfaces have a high anti-BSA loading of 780 ng/cm(2), together with achieving the ultralow (<3 ng/cm(2) for lysozyme and soybean milk) or low (<17 ng/cm(2) for cow milk and 10% blood serum) protein adsorptions. Additionally, the sensor chips also exhibited a high sensitivity to BSA over a wide range of concentrations from 15 to 700 nM. Our results demonstrate a promising antifouling surface using extremely hydrophilic HA as matrix to resist nonspecific adsorption from complex media in SPR biosensors.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25026640     DOI: 10.1021/am502921z

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  6 in total

1.  Enhanced corrosion resistance and cytocompatibility of biomimetic hyaluronic acid functionalised silane coating on AZ31 Mg alloy for orthopaedic applications.

Authors:  Sankalp Agarwal; Marie-Noelle Labour; David Hoey; Brendan Duffy; James Curtin; Swarna Jaiswal
Journal:  J Mater Sci Mater Med       Date:  2018-08-28       Impact factor: 3.896

2.  A nonfouling voltammetric immunosensor for the carcinoembryonic antigen based on the use of polyaniline nanowires wrapped with hyaluronic acid.

Authors:  Jiasheng Wang; Ni Hui
Journal:  Mikrochim Acta       Date:  2018-06-16       Impact factor: 5.833

Review 3.  Recent Advancements in Receptor Layer Engineering for Applications in SPR-Based Immunodiagnostics.

Authors:  Marcin Drozd; Sylwia Karoń; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-05-29       Impact factor: 3.576

4.  Recent advances to accelerate re-endothelialization for vascular stents.

Authors:  Tarek M Bedair; Mahmoud A ElNaggar; Yoon Ki Joung; Dong Keun Han
Journal:  J Tissue Eng       Date:  2017-09-28       Impact factor: 7.813

Review 5.  Low-Fouling Substrates for Plasmonic Sensing of Circulating Biomarkers in Biological Fluids.

Authors:  Elba Mauriz
Journal:  Biosensors (Basel)       Date:  2020-06-10

6.  Self-regenerating giant hyaluronan polymer brushes.

Authors:  Wenbin Wei; Jessica L Faubel; Hemaa Selvakumar; Daniel T Kovari; Joanna Tsao; Felipe Rivas; Amar T Mohabir; Michelle Krecker; Elaheh Rahbar; Adam R Hall; Michael A Filler; Jennifer L Washburn; Paul H Weigel; Jennifer E Curtis
Journal:  Nat Commun       Date:  2019-12-04       Impact factor: 14.919

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.