| Literature DB >> 25025554 |
Julia Caroline Schmidt1, Miriam Bux2, Elisabeth Filipuzzi-Jenny2, Eva Maria Kulik2, Tuomas Waltimo2, Roland Weiger1, Clemens Walter1.
Abstract
OBJECTIVES: The intraoral transmission of cariogenic and periodontopathogenic species seems to be facilitated by contaminated toothbrushes and other oral hygiene devices. The aim of this investigation was to analyze the in vitro retention and survival rate of Streptococcus mutans and Streptococcus sanguinis on different toothbrushes. The impacts of human saliva and antimicrobial toothpaste on these parameters were further evaluated.Entities:
Mesh:
Substances:
Year: 2014 PMID: 25025554 PMCID: PMC4072264 DOI: 10.1590/1678-775720130017
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Characteristics of the toothbrushes used in the study
| Model | Number of bristles | Dimension of head (mm) | Hardness | Length of bristles (mm) | Additional characteristics |
|---|---|---|---|---|---|
| Colgate 360° | 1323 | 26x11 | medium | 9-12 | soft rubber polishing cups, tongue and cheek cleaner |
| Curaprox CS5460 | 5460 | 22x11 | medium | 9 | - |
| Elmex nterX | 648-702 | 21x9 | soft | 10-12 | some bristles at a 60° angle to the rest of bristles |
| Trisa Flexible Head | 1916 | 26x9 | medium | 10-12 | flexible head |
as described by the respective manufacturer
Influence of time, toothpaste and saliva on the reduction of streptococcal retention on four different toothbrushes. Either no saliva or saliva collected from a caries-inactive (CI) or a caries-active (CA) volunteer was used, and the artificially contaminated toothbrushes were analyzed after either three minutes (T0) or 24 hours (T24). The reductions in bacterial counts are shown as the mean-log10 factors and standard deviations. Two independent experiments (n=2) were performed for each set of parameters. A higher number indicates a greater bacterial reduction, and "≥" denotes reductions to levels below the respective detection limits
| Toothbrush and bacteria | Without toothpaste | With toothpaste | ||||||
|---|---|---|---|---|---|---|---|---|
| no saliva | CI | CA | no saliva | CI | CA | |||
| T0 | T24 | T0 | T0 | T0 | T24 | T0 | T0 | |
| Colgate 360º | ||||||||
| 2.15±0.10 | 5.84±0.32 | 2.04±0.13 | 1.96±0.05 | 2.15±0.05 | ≥ 6.35±0.13 | 1.91±0.08 | 1.79±0.17 | |
| 2.16±0.19 | 2.97±0.09 | 1.76±0.02 | 1.78±0.19 | 2.27±0.09 | 3.5±0.15 | 1.70±0.04 | 1.94±0.05 | |
| Curaprox CS5460 | ||||||||
| 2.64±0.01 | ≥ 6.76±0.04 | 2.10±0.25 | 2.27±0.07 | 2.35±0.09 | ≥ 6.25±0.21 | 1.95±0.19 | 2.04±0.01 | |
| 2.40±0.16 | 3.51±0.16 | 2.01±0.02 | 2.37±0.05 | 2.13±0.05 | 5.27±0.23 | 1.48±0.26 | 1.58±0.05 | |
| Elmex interX | ||||||||
| 2.58±0.18 | ≥ 6.59±0.04 | 2.23±0.25 | 2.11±0.18 | 2.36±0.02 | ≥ 6.25±0.01 | 1.95±0.22 | 2.07±0.12 | |
| 2.12±0.02 | 4.04±0.42 | 1.93±0.02 | 1.86±0.12 | 2.53±0.21 | 5.48±0.27 | 1.96±0.19 | 1.96±0.29 | |
| Trisa Flexible Head | ||||||||
| 2.47±0.03 | ≥ 6.64±0.01 | 1.86±0.17 | 1.96±0.13 | 2.11±0.06 | ≥ 6.42±0.01 | 1.90±0.20 | 2.05±0.13 | |
| 1.96±0.04 | 4.24±0.14 | 1.60±0.11 | 1.69±0.17 | 2.35±0.13 | 5.38±0.07 | 1.54±0.19 | 1.78±0.17 | |