Vascular responses in patients with and without diabetes mellitus after everolimus-eluting stent implantation.

Masamichi Iwasaki1, Hiromasa Otake, Toshiro Shinke, Masayuki Nakagawa, Hirotoshi Hariki, Tsuyoshi Osue, Takumi Inoue, Yu Taniguchi, Ryo Nishio, Hiroto Kinutani, Akihide Konishi, Noritoshi Hiranuma, Masaru Kuroda, Junya Shite, Ken-ichi Hirata.   

Abstract

BACKGROUND: Previous reports have shown potential disadvantages of limus-derivative drugs for the stenting treatment of patients with diabetes mellitus (DM). METHODS AND 
RESULTS: We studied 159 coronary artery lesions (DM: n=72, non-DM: n=87) in 123 patients treated with everolimus-eluting stent (EES) and who underwent scheduled 9-month follow-up angiography with optical coherence tomography (OCT) regardless of symptoms. In addition to standard OCT variables, neointimal unevenness score (maximum/average neointimal thickness) and stent eccentricity index (minimum/maximum stent diameter) were calculated for each cross-section. To investigate a potential baseline difference between DM and non-DM lesions, pre- and post-interventional intravascular ultrasound (IVUS) images were also evaluated as an IVUS subgroup analysis. The average neointimal thickness and neointimal coverage did not differ between DM and non-DM patients. DM patients had, however, greater asymmetric stent expansion and variability of neointimal thickness than non-DM patients. There was a weak, but significant association between average stent eccentricity index and neointimal unevenness score. The IVUS substudy showed that the culprit plaque volume and plaque eccentricity in DM patients were significantly greater than in non-DM patients.
CONCLUSIONS: Although EES provided a similar level of average neointimal thickness and coverage both in the presence and absence of DM, uneven neointimal suppression occurred in DM patients. A larger plaque volume of the culprit lesion may hamper symmetric stent expansion, possibly explaining the non-uniform neointimal suppression in DM patients.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25017738     DOI: 10.1253/circj.cj-13-1540

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  2 in total

1.  Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.

Authors:  Hirofumi Ohtani; Shigeki Kimura; Tomoyo Sugiyama; Keiichi Hishikari; Toru Misawa; Masafumi Mizusawa; Kazuto Hayasaka; Yosuke Yamakami; Keisuke Kojima; Yuichiro Sagawa; Hiroyuki Hikita; Takashi Ashikaga; Atsushi Takahashi; Mitsuaki Isobe
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-19       Impact factor: 2.357

2.  Efficacy of Zotarolimus-Eluting Stents in Treating Diabetic Coronary Lesions: An Optical Coherence Tomography Study.

Authors:  Zhengbin Zhu; Jinzhou Zhu; Run Du; Haotian Zhang; Jinwei Ni; Weiwei Quan; Jian Hu; Fenghua Ding; Zhenkun Yang; Ruiyan Zhang
Journal:  Adv Ther       Date:  2020-03-07       Impact factor: 3.845

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.