Literature DB >> 25017451

Contrast-induced acute kidney injury after computed tomography prior to transcatheter aortic valve implantation.

D Jochheim1, V-S Schneider2, F Schwarz2, C Kupatt3, P Lange3, M Reiser2, S Massberg3, J-L Gutiérrez-Chico3, J Mehilli3, H-C Becker2.   

Abstract

AIM: To identify independent predictors of contrast medium-induced acute kidney injury (CI-AKI) after enhanced multidetector-row computed tomography (MDCT) prior to transcatheter aortic valve implantation (TAVI) in high-risk patients.
MATERIALS AND METHODS: The present single-centre study analysed retrospectively 361 patients who were assessed using MDCT prior to TAVI. CI-AKI was defined as an increase in serum creatinine (SCr) of ≥ 25% or ≥ 0.5 mg/dl in at least one sample over baseline (24 h before MDCT) and at 24, 48, and 72 h after MDCT.
RESULTS: A total of 38 patients (10.5%) experienced CI-AKI. As compared to patients without CI-AKI, they presented more frequently with estimated glomerular filtration rate (eGFR) <60 ml/min/1.73 m(2), (81.6% versus 64.4%, p = 0.045) and tended to receive higher volumes of iodinated contrast media (ICM; 55.3% versus 39%, p = 0.057). There was a significant interaction between baseline eGFR and the amount of intravenous ICM administered (pfor interaction = <0.001) identifying the amount of ICM >90 ml as independent predictive factor of CI-AKI only in patients with baseline eGFR <60 ml/min/1.73m(2) (OR 2.615; 95% CI: 1.21-5.64).
CONCLUSION: One in ten elderly patients with aortic stenosis undergoing MDCT to plan a TAVI procedure experienced CI-AKI after intravenous ICM injection. Intravenous administration of <90 ml of ICM reduces this risk in patients with or without pre-existing impaired renal function. However, in the majority of patients renal function recovers before the TAVI procedure.
Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25017451     DOI: 10.1016/j.crad.2014.05.106

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  6 in total

1.  Guideline on the use of iodinated contrast media in patients with kidney disease 2018.

Authors:  Yoshitaka Isaka; Hiromitsu Hayashi; Kazutaka Aonuma; Masaru Horio; Yoshio Terada; Kent Doi; Yoshihide Fujigaki; Hideo Yasuda; Taichi Sato; Tomoyuki Fujikura; Ryohei Kuwatsuru; Hiroshi Toei; Ryusuke Murakami; Yoshihiko Saito; Atsushi Hirayama; Toyoaki Murohara; Akira Sato; Hideki Ishii; Tadateru Takayama; Makoto Watanabe; Kazuo Awai; Seitaro Oda; Takamichi Murakami; Yukinobu Yagyu; Nobuhiko Joki; Yasuhiro Komatsu; Takamasa Miyauchi; Yugo Ito; Ryo Miyazawa; Yoshihiko Kanno; Tomonari Ogawa; Hiroki Hayashi; Eri Koshi; Tomoki Kosugi; Yoshinari Yasuda
Journal:  Clin Exp Nephrol       Date:  2020-01       Impact factor: 2.801

2.  Guideline on the use of iodinated contrast media in patients with kidney disease 2018.

Authors:  Yoshitaka Isaka; Hiromitsu Hayashi; Kazutaka Aonuma; Masaru Horio; Yoshio Terada; Kent Doi; Yoshihide Fujigaki; Hideo Yasuda; Taichi Sato; Tomoyuki Fujikura; Ryohei Kuwatsuru; Hiroshi Toei; Ryusuke Murakami; Yoshihiko Saito; Atsushi Hirayama; Toyoaki Murohara; Akira Sato; Hideki Ishii; Tadateru Takayama; Makoto Watanabe; Kazuo Awai; Seitaro Oda; Takamichi Murakami; Yukinobu Yagyu; Nobuhiko Joki; Yasuhiro Komatsu; Takamasa Miyauchi; Yugo Ito; Ryo Miyazawa; Yoshihiko Kanno; Tomonari Ogawa; Hiroki Hayashi; Eri Koshi; Tomoki Kosugi; Yoshinari Yasuda
Journal:  Jpn J Radiol       Date:  2020-01       Impact factor: 2.374

Review 3.  3D transoesophageal echocardiography in the TAVI sizing arena: should we do it and how do we do it?

Authors:  Caroline Bleakley; Mehdi Eskandari; Mark Monaghan
Journal:  Echo Res Pract       Date:  2017-03

Review 4.  Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Chanrith Mork; Minjie Wei; Weixi Jiang; Jianli Ren; Haitao Ran
Journal:  Diagnostics (Basel)       Date:  2021-04-22

5.  Long-Term Outcomes After Transfemoral-Transcatheter Aortic Valve Implantation in Very Old Patients Using the Balloon-Expandable Bioprosthesis.

Authors:  Dritan Useini; Markus Schlömicher; Assem Aweimer; Peter Haldenwang; Justus Strauch; Polykarpos C Patsalis
Journal:  Gerontol Geriatr Med       Date:  2022-01-19

6.  International Expert Consensus on Sutureless and Rapid Deployment Valves in Aortic Valve Replacement Using Minimally Invasive Approaches.

Authors:  Mattia Glauber; Simon C Moten; Eugenio Quaini; Marco Solinas; Thierry A Folliguet; Bart Meuris; Antonio Miceli; Peter J Oberwalder; Manfredo Rambaldini; Kevin H T Teoh; Gopal Bhatnagar; Michael A Borger; Denis Bouchard; Olivier Bouchot; Stephen C Clark; Otto E Dapunt; Matteo Ferrarini; Theodor J M Fischlein; Guenther Laufer; Carmelo Mignosa; Russell Millner; Philippe Noirhomme; Steffen Pfeiffer; Xavier Ruyra-Baliarda; Malakh Lal Shrestha; Rakesh M Suri; Giovanni Troise; Borut Gersak
Journal:  Innovations (Phila)       Date:  2016 May-Jun
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.