New method for geometric calibration and distortion correction of conventional C-arm.

Cai Meng1, Jun Zhang2, Fugen Zhou2, Tianmiao Wang3.   

Abstract

Image distortion correction and geometric calibration are critical operations for using C-arm DSA (Digital Subtraction Angiography) images to digitally navigate vascular interventional surgery. In traditional ways, C-arm images are corrected with global or local correction methods where a supposed virtual ideal image is needed, and then the corrected images are utilized to calibrate the C-arm with a pin-hole model. In this paper, we propose a new method to calibrate the C-arm with a nonlinear model and to improve navigation performance. We first calibrate the C-arm with a nonlinear model and then the distortion correction is accomplished without virtual ideal image. In this paper, the nonlinear model of C-arm imaging system is addressed at first, and then the C-arm is calibrated with a two-stage method. In the first stage, the C-arm is calibrated with the markers in image center by RAC (radial alignment constraint) method, and in the second stage the calibration parameters are optimized with Levenberg-Marquadt algorithm by minimizing the sum of the square of difference between all markers׳ real distorted positions and their theoretical distorted positions in the phantom image. Based on the calibration result, the image distortion can be corrected. To verify our method, experiments were conducted with a conventional DSA C-arm machine in hospital. The errors in distortion correction and 3D (three-dimensional) reconstruction were quantitatively compared with the global polynomial correction method and visual model method, and the results showed that the proposed method had better performance in distortion correction and 3D reconstruction.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Keywords:  C-arm machine; Distortion correction; Geometric calibration; Two-stage calibration; X-ray fluoroscopy

Mesh:

Year:  2014        PMID: 25014497     DOI: 10.1016/j.compbiomed.2014.06.009

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  3 in total

1.  Precise 3D/2D calibration between a RGB-D sensor and a C-arm fluoroscope.

Authors:  Xiang Wang; Severine Habert; Meng Ma; Chun-Hao Huang; Pascal Fallavollita; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-01-25       Impact factor: 2.924

2.  Perspective pinhole model with planar source for augmented reality surgical navigation based on C-arm imaging.

Authors:  Ho-Gun Ha; Sangseo Jeon; Seongpung Lee; Hyunseok Choi; Jaesung Hong
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-07-16       Impact factor: 2.924

3.  Influence of multi-angle input of intraoperative fluoroscopic images on the spatial positioning accuracy of the C-arm calibration-based algorithm of a CAOS system.

Authors:  Xiangqian Chen; Yu Wang; Gang Zhu; Weijun Zhang; Gang Zhou; Yubo Fan
Journal:  Med Biol Eng Comput       Date:  2020-01-09       Impact factor: 2.602

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.