| Literature DB >> 25010468 |
Abstract
In this work, the results obtained from studying the anodic dissolution of pureEntities:
Mesh:
Substances:
Year: 2014 PMID: 25010468 PMCID: PMC6270819 DOI: 10.3390/molecules19079962
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Figure 1Potentiodynamic polarization curves for (1) pure iron and (2) API X-65 steel after their immersions for 40 min in 4.0 wt % NaCl solutions.
Figure 2Potentiodynamic polarization curves for (1) pure iron and (2) API X-65 steel after their immersion for 12 h in 4.0 wt % NaCl solutions.
Parameters obtained from potentiodynamic polarization curves shown in Figure 2 and Figure 3 for iron and API X-65 steel after 40 min and 12 h immersion in 4.0 wt % NaCl solutions.
| Material/Time | Parameter | |||||
|---|---|---|---|---|---|---|
| βc/mVdec−1 | jCorr/μAcm−2 | ECorr/mV | βa/mVdec−1 | Rp/Ωcm2 | RCorr/mmy−1 | |
| Iron (40 min) | 70 | 28 | −985 | 80 | 580 | 0.326 |
| X-65 (40 min) | 90 | 15 | −823 | 125 | 1517 | 0.174 |
| Iron (720 min) | 95 | 18 | −907 | 115 | 1257 | 0.209 |
| X-65 (720 min) | 105 | 10 | −862 | 140 | 2609 | 0.116 |
Figure 3Chronoamperometric current-time curves obtained at −0.350 V vs. Ag/AgCl for (1) iron and (2) API X-65 steel electrodes after 40 min immersions in 4.0 wt % NaCl solutions.
Figure 4Chronoamperometric current-time curves obtained at −0.350 V vs. Ag/AgCl for (1) iron and (2) API X-65 steel electrodes after 12 h immersions in 4.0 wt % NaCl solutions.
Figure 5Potential-time curves obtained for (1) pure iron and (2) API X-65 5 L pipeline steel, respectively in 4.0 wt % NaCl solutions.
Figure 6EIS Nyquist for (1) pure iron and (2) API X-65 steel at corrosion potential after 40 min immersion in 4.0 wt % NaCl solutions.
Figure 7EIS Nyquist plots for (1) pure iron and (2) API X-65 steel at corrosion potential after 12 h immersion in 4.0 wt % NaCl solutions.
Figure 8The equivalent circuit model used to fit the EIS experimental data.
Figure 9EIS Nyquist plot for pure iron after 40 min immersion in 4.0 wt % NaCl solution; symbols represent the measured data and solid line represents the best fit using the equivalent circuit shown in Figure 8.
EIS parameters obtained by fitting the Nyquist plots shown in Figure 6 and Figure 7 with the equivalent circuit shown in Figure 8 for iron and API X-65 steel after 1 and 12 h immersion in 4.0 wt % NaCl solutions.
| Material/Time | Parameter | ||||||
|---|---|---|---|---|---|---|---|
| RS/Ω cm2 | Q1 (CPEs) | RP1/Ω cm2 | Q2 (CPEs) | RP2/Ω cm2 | |||
| YQ1/μF cm−2 | YQ2/μF cm−2 | ||||||
| Iron (40 min) | 6.47 | 7.44 | 0.93 | 795 | 6.17 | 0.73 | 1167 |
| X-65 (40 min) | 7.73 | 5.51 | 1.0 | 897 | 4.98 | 0.74 | 1293 |
| Iron (720 min) | 6.75 | 6.35 | 1.0 | 1102 | 4.69 | 0.72 | 1524 |
| X-65 (720 min) | 8.87 | 4.04 | 1.0 | 1223 | 3.74 | 0.80 | 2415 |