Literature DB >> 25005346

Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using CZT-SPECT.

J D van Dijk1, P L Jager, M Mouden, C H Slump, J P Ottervanger, J de Boer, A H J Oostdijk, J A van Dalen.   

Abstract

BACKGROUND: Guidelines for SPECT myocardial perfusion imaging (MPI) traditionally recommend a fixed tracer dose. Yet, clinical practice shows degraded image quality in heavier patients. The aim was to optimize and validate the tracer dose and scan time to obtain a constant image quality less dependent on patients' physical characteristics.
METHODS: 125 patients underwent Cadmium Zinc Telluride (CZT)-SPECT stress MPI using a fixed Tc-99m-tetrofosmin tracer dose. Image quality was scored by three physicians on a 4-point grading scale and related to the number of photon counts normalized to tracer dose and scan time. Counts were correlated with various patient-specific parameters dealing with patient size and weight to find the best predicting parameter. From these data, a formula to provide constant image quality was derived, and subsequently tested in 92 new patients.
RESULTS: Degradation in image quality and photon counts was observed for heavier patients for all patients' specific parameters (P < .01). We found body weight to be the best-predicting parameter for image quality and derived a new dose formula. After applying this new body weight-depended tracer dose and scan time in a new group, image quality was found to be constant (P > .19) in all patients.
CONCLUSIONS: Also in CZT SPECT image quality decreases with weight. The use of a tracer dose and scan time that depends linearly on patient's body weight corrected for the varying image quality in CZT-SPECT MPI. This leads to better radiation exposure justification.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25005346     DOI: 10.1007/s12350-014-9942-0

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  27 in total

1.  American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: attenuation correction of myocardial perfusion SPECT scintigraphy.

Authors:  Gary V Heller; Jonathan Links; Timothy M Bateman; Jack A Ziffer; Edward Ficaro; Mylan C Cohen; Robert C Hendel
Journal:  J Nucl Cardiol       Date:  2004 Mar-Apr       Impact factor: 5.952

Review 2.  Cardiac dedicated ultrafast SPECT cameras: new designs and clinical implications.

Authors:  Ernest V Garcia; Tracy L Faber; Fabio P Esteves
Journal:  J Nucl Med       Date:  2011-01-13       Impact factor: 10.057

3.  Should clearance be normalised to body surface or to lean body mass?

Authors:  T H Hallynck; H H Soep; J A Thomis; J Boelaert; R Daneels; L Dettli
Journal:  Br J Clin Pharmacol       Date:  1981-05       Impact factor: 4.335

4.  Prediction of lean body mass from height and weight.

Authors:  R Hume
Journal:  J Clin Pathol       Date:  1966-07       Impact factor: 3.411

5.  Reduced isotope dose with rapid SPECT MPI imaging: initial experience with a CZT SPECT camera.

Authors:  W Lane Duvall; Lori B Croft; Tapan Godiwala; Eric Ginsberg; Titus George; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2010-11-12       Impact factor: 5.952

6.  Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC).

Authors:  Albert Flotats; Juhani Knuuti; Matthias Gutberlet; Claudio Marcassa; Frank M Bengel; Philippe A Kaufmann; Michael R Rees; Birger Hesse
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01       Impact factor: 9.236

7.  Biokinetics of technetium-99m-tetrofosmin: myocardial perfusion imaging agent: implications for a one-day imaging protocol.

Authors:  D Jain; F J Wackers; J Mattera; M McMahon; A J Sinusas; B L Zaret
Journal:  J Nucl Med       Date:  1993-08       Impact factor: 10.057

8.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

9.  Assessing the effect of increasing injection activity for myocardial perfusion imaging in overweight patients.

Authors:  A Notghi; F X Sundram; J W O'Brien; N B Smith
Journal:  Br J Radiol       Date:  2008-06-09       Impact factor: 3.039

Review 10.  Myocardial perfusion scintigraphy: the evidence.

Authors:  S R Underwood; C Anagnostopoulos; M Cerqueira; P J Ell; E J Flint; M Harbinson; A D Kelion; A Al-Mohammad; E M Prvulovich; L J Shaw; A C Tweddel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

View more
  13 in total

1.  Patient centered imaging and the dose of radiopharmaceuticals.

Authors:  Randall C Thompson; Eric V Burgett
Journal:  J Nucl Cardiol       Date:  2015-09-09       Impact factor: 5.952

2.  Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.

Authors:  Min Liu; Yumin Zheng; Ugur Avcibasi; Shuang Liu
Journal:  Nucl Med Biol       Date:  2016-05-09       Impact factor: 2.408

Review 3.  Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation.

Authors:  Sharmila Dorbala; Karthik Ananthasubramaniam; Ian S Armstrong; Panithaya Chareonthaitawee; E Gordon DePuey; Andrew J Einstein; Robert J Gropler; Thomas A Holly; John J Mahmarian; Mi-Ae Park; Donna M Polk; Raymond Russell; Piotr J Slomka; Randall C Thompson; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

4.  Can advances in nuclear cardiology hardware overcome the challenges of imaging obese patients?

Authors:  Ron Blankstein
Journal:  J Nucl Cardiol       Date:  2014-10-09       Impact factor: 5.952

5.  Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT.

Authors:  Shu Yokota; Mohamed Mouden; Jan Paul Ottervanger; Elsemiek Engbers; Siert Knollema; Jorik R Timmer; Pieter L Jager
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-09-21       Impact factor: 9.236

6.  Effect of a patient-specific minimum activity in stress myocardial perfusion imaging using CZT-SPECT: Prognostic value, radiation dose, and scan outcome.

Authors:  J D van Dijk; N M Borren; M Mouden; J A van Dalen; J P Ottervanger; P L Jager
Journal:  J Nucl Cardiol       Date:  2017-08-18       Impact factor: 5.952

7.  The very hungry caterpillar and the ongoing effort to reduce radiation in myocardial perfusion scintigraphy: Have we become the beautiful butterfly?

Authors:  Hein J Verberne; Asbjørn M Scholtens
Journal:  J Nucl Cardiol       Date:  2017-08-18       Impact factor: 5.952

8.  Patient-specific activity or scan-time in SPECT myocardial perfusion imaging: A hands-on approach.

Authors:  J D van Dijk; P L Jager; J A van Dalen
Journal:  J Nucl Cardiol       Date:  2017-09-06       Impact factor: 5.952

Review 9.  Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).

Authors:  Denis Agostini; Pierre-Yves Marie; Simona Ben-Haim; François Rouzet; Bernard Songy; Alessandro Giordano; Alessia Gimelli; Fabien Hyafil; Roberto Sciagrà; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-19       Impact factor: 9.236

10.  Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using conventional SPECT.

Authors:  J D van Dijk; P L Jager; J P Ottervanger; J de Boer; A H J Oostdijk; E M Engbers; C H Slump; S Knollema; J A van Dalen
Journal:  J Nucl Cardiol       Date:  2015-09-09       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.