Literature DB >> 25003865

Measure of chest wall thickness in French soldiers: which technique to use for needle decompression of tension pneumothorax at the front?

Antoine Lamblin1, Jean Turc1, Olivier Bylicki2, Damien Lohéas1, Jean-Yves Martinez1, Clément Derkenne1, Pierre-François Wey1, Pascal Précloux1.   

Abstract

OBJECTIVES: Needle decompression of tension pneumothorax in soldiers of the French infantry has a risk for failure when the standard procedure that involves the insertion of a 14-gauge, 5-cm catheter into the 2nd intercostal space (ICS) is used. This study measured the chest wall thickness (CWT) to assess whether this approach is appropriate.
METHODS: CWT was measured by ultrasound in 122 French soldiers at the 2nd and 4th ICSs on both the right and left sides.
RESULTS: CWT was measured at 4.19 cm (± 0.96 cm) at the 2nd ICS and 3.00 cm (± 0.91 cm) at the 4th ICS (p < 0.001). CWT was greater than 5 cm in 24.2% of cases at the 2nd ICS and 4.9% of cases at the 4th ICS (p < 0.001).
CONCLUSIONS: This study suggests a high risk of failure when using the technique currently taught in the French army. A lateral approach into the 4th ICS could decrease this risk. The results of this study must be validated in patients presenting tension pneumothorax. Reprint &
Copyright © 2014 Association of Military Surgeons of the U.S.

Entities:  

Mesh:

Year:  2014        PMID: 25003865     DOI: 10.7205/MILMED-D-13-00512

Source DB:  PubMed          Journal:  Mil Med        ISSN: 0026-4075            Impact factor:   1.437


  1 in total

Review 1.  Chest wall thickness and decompression failure: A systematic review and meta-analysis comparing anatomic locations in needle thoracostomy.

Authors:  Danuel V Laan; Trang Diem N Vu; Cornelius A Thiels; T K Pandian; Henry J Schiller; M Hassan Murad; Johnathon M Aho
Journal:  Injury       Date:  2015-12-13       Impact factor: 2.586

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.