Literature DB >> 24997617

Internal fixation with occipital hooks construct for occipito-cervical arthrodesis. Results in 14 young or small children.

Thierry Odent1, Rony Bou Ghosn, Jean-Paul Dusabe, Michel Zerah, Christophe Glorion.   

Abstract

PURPOSE: Evaluation of effectiveness of internal rigid fixation for occipito-cervical fusion with occipital hooks and cervical screws and/or hooks to improve fusion in young or small children with various bone dysplasia or congenital abnormality.
METHODS: Fourteen children with mean age of 8.4 years and height and weight below 140 cm and 35 kg, respectively, who underwent occipito-cervical fusion for miscellaneous pathologies reading to stenosis and/or instability were reviewed. The posterior instrumentation consisted of a precontoured titanium plate rod with an occipital fixation by hooks and a vertebral fixation by screws and/or hooks. Eight patients had cervical fixation with C2 pedicle screws. The mean follow-up was 48 months (27-81 months).
RESULTS: Thirteen patients (92.8 %) had a complete fusion and no failure of the fixation was observed. We had two deep wound infections not related to implants.
CONCLUSION: Instrumentation was technically feasible even in a very young child. Rigid internal fixation in the little children did not increase surgical complications and significantly increased the union rate of occipito-cervical arthrodesis.

Entities:  

Mesh:

Year:  2014        PMID: 24997617     DOI: 10.1007/s00586-014-3436-2

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  25 in total

1.  One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems.

Authors:  K Abumi; K Kaneda; Y Shono; M Fujiya
Journal:  J Neurosurg       Date:  1999-01       Impact factor: 5.115

Review 2.  Spine update: cervical spine internal fixation using screw and screw-plate constructs.

Authors:  G M McCullen; S R Garfin
Journal:  Spine (Phila Pa 1976)       Date:  2000-03-01       Impact factor: 3.468

3.  Pediatric spinal trauma. Review of 122 cases of spinal cord and vertebral column injuries.

Authors:  M N Hadley; J M Zabramski; C M Browner; H Rekate; V K Sonntag
Journal:  J Neurosurg       Date:  1988-01       Impact factor: 5.115

4.  Occipitocervical arthrodesis. Indications, technic and results.

Authors:  S A Grantham; H M Dick; R C Thompson; F E Stinchfield
Journal:  Clin Orthop Relat Res       Date:  1969 Jul-Aug       Impact factor: 4.176

5.  Occipitocervical arthrodesis in children.

Authors:  M Letts; D Slutsky
Journal:  J Bone Joint Surg Am       Date:  1990-09       Impact factor: 5.284

6.  C1-C2 posterior fusion in growing patients: long-term follow-up.

Authors:  Patrizio Parisini; Mario Di Silvestre; Tiziana Greggi; Giuseppe Bianchi
Journal:  Spine (Phila Pa 1976)       Date:  2003-03-15       Impact factor: 3.468

7.  Experience of posterior surgery in atlanto-axial instability.

Authors:  P C Lee; S Y Chun; J C Leong
Journal:  Spine (Phila Pa 1976)       Date:  1984-04       Impact factor: 3.468

8.  Pediatric subaxial cervical spine injuries: origins, management, and outcome in 51 patients.

Authors:  Seref Dogan; Sam Safavi-Abbasi; Nicholas Theodore; Eric Horn; Harold L Rekate; Volker K H Sonntag
Journal:  Neurosurg Focus       Date:  2006-02-15       Impact factor: 4.047

9.  Feasibility of rigid upper cervical instrumentation in children: tomographic analysis of children aged 2-6.

Authors:  Matthew J Geck; Eeric Truumees; Dana Hawthorne; Devender Singh; John K Stokes; Amy Flynn
Journal:  J Spinal Disord Tech       Date:  2014-05

10.  Occipito-cervical fusion reinforced by Luque's segmental spinal instrumentation for rheumatoid diseases.

Authors:  T Itoh; H Tsuji; Y Katoh; T Yonezawa; H Kitagawa
Journal:  Spine (Phila Pa 1976)       Date:  1988-11       Impact factor: 3.468

View more
  1 in total

1.  Instrumented cervical spinal fusions in children: indications and outcomes.

Authors:  M Lastikka; J Aarnio; I Helenius
Journal:  J Child Orthop       Date:  2017-12-01       Impact factor: 1.548

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.