Literature DB >> 24993925

Software tools and surgical guides in dental-implant-guided surgery.

Maria A Mora1, Douglas L Chenin2, Roger M Arce3.   

Abstract

Cone beam computed tomography has become an essential tool in the diagnosis and planning for implant dentistry. New hardware and software developments have emerged to help implant surgeons to successfully adopt and use different systems in patients requiring prosthetically driven implant dentistry. However, there is the need to develop an adequate planning protocol that includes appropriate acquisition/data manipulation, appropriate use of software tools for interpretation, and appropriate application of such systems during implant surgery. This article examines essential characteristics of the entire implant-guided surgery planning process and points out potential sources of error that could affect clinical accuracy outcomes.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Accuracy; Cone beam computed tomography; Implant-guided surgery; Optical scanning; Software; Stereolithographic

Mesh:

Year:  2014        PMID: 24993925     DOI: 10.1016/j.cden.2014.04.001

Source DB:  PubMed          Journal:  Dent Clin North Am        ISSN: 0011-8532


  9 in total

1.  Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement.

Authors:  Silvia Izabella Pop; Mircea Dudescu; Sorin Gheorghe Mihali; Mariana Păcurar; Dana Cristina Bratu
Journal:  Polymers (Basel)       Date:  2022-05-21       Impact factor: 4.967

2.  A Novel Method for Digital Reconstruction of the Mucogingival Borderline in Optical Scans of Dental Plaster Casts.

Authors:  Leonard Simon Brandenburg; Stefan Schlager; Lara Sophie Harzig; David Steybe; René Marcel Rothweiler; Felix Burkhardt; Benedikt Christopher Spies; Joachim Georgii; Marc Christian Metzger
Journal:  J Clin Med       Date:  2022-04-24       Impact factor: 4.964

3.  From Guided Surgery to Final Prosthesis with a Fully Digital Procedure: A Prospective Clinical Study on 15 Partially Edentulous Patients.

Authors:  Giorgio Andrea Dolcini; Marco Colombo; Carlo Mangano
Journal:  Int J Dent       Date:  2016-07-14

4.  Multivariate analysis of causal factors influencing accuracy of guided implant surgery for partial edentulism: a retrospective clinical study.

Authors:  Atsushi Matsumura; Tamaki Nakano; Shinji Ono; Akihiro Kaminaka; Hirofumi Yatani; Daijiro Kabata
Journal:  Int J Implant Dent       Date:  2021-04-19

5.  Comparison of Implant Placement Accuracy in Healed and Fresh Extraction Sockets between Static and Dynamic Computer-Assisted Implant Surgery Navigation Systems: A Model-Based Evaluation.

Authors:  Miaozhen Wang; Xiaohui Rausch-Fan; Yalin Zhan; Huidan Shen; Feng Liu
Journal:  Materials (Basel)       Date:  2022-04-11       Impact factor: 3.748

6.  A new concept for implant-borne dental rehabilitation; how to overcome the biological weak-spot of conventional dental implants?

Authors:  Nils-Claudius Gellrich; Björn Rahlf; Rüdiger Zimmerer; Philipp-Cornelius Pott; Majeed Rana
Journal:  Head Face Med       Date:  2017-09-29       Impact factor: 2.151

Review 7.  Cone beam computed tomography in implant dentistry: recommendations for clinical use.

Authors:  Reinhilde Jacobs; Benjamin Salmon; Marina Codari; Bassam Hassan; Michael M Bornstein
Journal:  BMC Oral Health       Date:  2018-05-15       Impact factor: 2.757

8.  Accuracy of mucosa supported guided dental implant surgery.

Authors:  Andoni Jones
Journal:  Clin Case Rep       Date:  2018-09-23

9.  Influence of bone condition on implant placement accuracy with computer-guided surgery.

Authors:  Ramadhan Hardani Putra; Nobuhiro Yoda; Masahiro Iikubo; Yoshihiro Kataoka; Kensuke Yamauchi; Shigeto Koyama; Upul Cooray; Eha Renwi Astuti; Tetsu Takahashi; Keiichi Sasaki
Journal:  Int J Implant Dent       Date:  2020-09-20
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.