Optimizing cone beam CT scatter estimation in egs_cbct for a clinical and virtual chest phantom.

Rune Slot Thing1, Ernesto Mainegra-Hing2.   

Abstract

PURPOSE: Cone beam computed tomography (CBCT) image quality suffers from contamination from scattered photons in the projection images. Monte Carlo simulations are a powerful tool to investigate the properties of scattered photons.egs_cbct, a recent EGSnrc user code, provides the ability of performing fast scatter calculations in CBCT projection images. This paper investigates how optimization of user inputs can provide the most efficient scatter calculations.
METHODS: Two simulation geometries with two different x-ray sources were simulated, while the user input parameters for the efficiency improving techniques (EITs) implemented inegs_cbct were varied. Simulation efficiencies were compared to analog simulations performed without using any EITs. Resulting scatter distributions were confirmed unbiased against the analog simulations.
RESULTS: The optimal EIT parameter selection depends on the simulation geometry and x-ray source. Forced detection improved the scatter calculation efficiency by 80%. Delta transport improved calculation efficiency by a further 34%, while particle splitting combined with Russian roulette improved the efficiency by a factor of 45 or more. Combining these variance reduction techniques with a built-in denoising algorithm, efficiency improvements of 4 orders of magnitude were achieved.
CONCLUSIONS: Using the built-in EITs inegs_cbct can improve scatter calculation efficiencies by more than 4 orders of magnitude. To achieve this, the user must optimize the input parameters to the specific simulation geometry. Realizing the full potential of the denoising algorithm requires keeping the statistical uncertainty below a threshold value above which the efficiency drops exponentially.

Entities:  

Mesh:

Year:  2014        PMID: 24989380     DOI: 10.1118/1.4881142

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Scatter Reduction and Correction for Dual-Source Cone-Beam CT Using Prepatient Grids.

Authors:  Lei Ren; Yingxuan Chen; You Zhang; William Giles; Jianyue Jin; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2015-05-24

2.  A model-based scatter artifacts correction for cone beam CT.

Authors:  Wei Zhao; Don Vernekohl; Jun Zhu; Luyao Wang; Lei Xing
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

3.  Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation.

Authors:  Alexander Maslowski; Adam Wang; Mingshan Sun; Todd Wareing; Ian Davis; Josh Star-Lack
Journal:  Med Phys       Date:  2018-04-06       Impact factor: 4.071

4.  Set-up error validation with EPID images: Measurements vs Egs_cbct simulation.

Authors:  D van Eeden; F H J O'Reilly; F C P du Plessis
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-21

5.  Multi-Energy Computed Tomography Breast Imaging with Monte Carlo Simulations: Contrast-to-Noise-Based Image Weighting.

Authors:  Déte Van Eeden; Freek C P Du Plessis
Journal:  J Med Phys       Date:  2019 Apr-Jun

6.  Implementation of an efficient Monte Carlo calculation for CBCT scatter correction: phantom study.

Authors:  Peter G F Watson; Ernesto Mainegra-Hing; Nada Tomic; Jan Seuntjens
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102