Literature DB >> 24988882

Fit of zirconia all-ceramic crowns with different cervical margin designs, before and after porcelain firing and glazing.

Shoko Miura1, Ryoichi Inagaki, Shin Kasahara, Masanobu Yoda.   

Abstract

The purpose of this study is to investigate the fit of zirconia cores and all-ceramic crowns prepared with different cervical margin designs. The radius of curvature between the axial wall and the occlusal surface was set to 1 mm in an abutment using the cervical shoulder marginal design (S) and to 0.2 and 0.5 mm in abutments with round shoulders (0.2RS and 0.5RS, respectively). The internal gaps of the cores were 45-138 μm (S), 41-141 μm (0.2RS), and 43-133 μm (0.5RS). The internal gaps of the all-ceramic crowns were 40-115 μm (S), 45-113 μm (0.2RS), and 42-126 μm (0.5RS). There were no significant differences in one-way ANOVA for any region in any marginal design before and after firing the porcelain. The marginal gaps between the all-ceramic crowns and dies were 27 ± 25 (S), 30 ± 29 (0.2RS), and 24 ± 27 μm (0.5RS), again with no significant differences in one-way ANOVA.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24988882     DOI: 10.4012/dmj.2013-284

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  6 in total

1.  Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study.

Authors:  Shoko Miura; Shin Kasahara; Shinobu Yamauchi; Yayoi Okuyama; Akio Izumida; Jun Aida; Hiroshi Egusa
Journal:  Clin Oral Investig       Date:  2017-06-12       Impact factor: 3.573

2.  The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings.

Authors:  Sabit Melih Ates; Zeynep Yesil Duymus; Ipek Caglar; Bilal Hologlu
Journal:  Clin Oral Investig       Date:  2017-01-13       Impact factor: 3.573

3.  The effect of various veneering techniques on the marginal fit of zirconia copings.

Authors:  Kianoosh Torabi; Mahroo Vojdani; Rashin Giti; Masumeh Taghva; Soheil Pardis
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

Review 4.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07

5.  Marginal Fit of Full Contour Monolithic Zirconia in Different Thicknesses and Layered Zirconia Crowns.

Authors:  Mina Mohaghegh; Maryam Firouzmandi; Elham Ansarifard; Laleh Ramazani
Journal:  J Int Soc Prev Community Dent       Date:  2020-09-28

Review 6.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.