| Literature DB >> 24988467 |
Mikko Taina1, Miika Korhonen1, Mika Haataja1, Antti Muuronen1, Otso Arponen1, Marja Hedman2, Pekka Jäkälä3, Petri Sipola1, Pirjo Mustonen4, Ritva Vanninen1.
Abstract
OBJECTIVES: Left atrial appendage (LAA) dilatation and morphology may influence an individual's risk for intracardiac thrombi and ischemic stroke. LAA size and morphology can be evaluated using cardiac computed tomography (cCT). The present study evaluated the reproducibility of LAA volume and morphology assessments.Entities:
Mesh:
Year: 2014 PMID: 24988467 PMCID: PMC4079282 DOI: 10.1371/journal.pone.0101580
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Study design for reproducibility analyses.
Clinical Characteristics of Patients.
| Characteristic | Morphology analysis n = 149 | Volumetric analysis n = 40 |
|
| Age, yr | 60.9±10.6 | 60.1±9.7 | ns. |
| Females, n (%) | 47 (31.5) | 11 (38.2) | ns. |
| Body mass index, kg/m2 | 28.1±4.4 | 29.2±4.0 | ns. |
| Body surface area, m2 | 2.0±0.2 | 2.0±0.2 | ns. |
| Caucasian race, n (%) | 149 (100.0) | 40 (100.0) | ns. |
| Hypertension, n (%) | 88 (59.1) | 21 (52.5) | ns. |
| Hyperlipidaemia, n (%) | 61 (40.9) | 18 (45.0) | ns. |
| Diabetes, n (%) | 22 (17.8) | 3 (7.5) | ns. |
| Smokers, n (%) | 38 (25.5) | 7 (17.5) | ns. |
| Prior stroke, n (%) | 29 (19.5) | 5 (12.5) | ns. |
| Prior myocardial infarction, n (%) | 19 (12.8) | 4 (10.0) | ns. |
| Sinus rhythm during imaging, n (%) | 149 (100.0) | 40 (100.0) | ns. |
| Heart rate, beats per minute | 67.3±11.2 | 66.7±10.0 | ns. |
| PAF in 24 hour ECG Holter, n (%) | 38 (25.5) | 1 (2.5) | 0.033 |
| Thrombus in LAA, n (%) | 3 (2.0) | 0 (0.0) | ns. |
Sig = significance; ns = not significant in level P<0.05; PAF = paroxysmal atrial fibrillation.
Interobserver and Intra-observer Reproducibility Analysis of Left Atrial Appendage (LAA) and Left Atrium (LA) Volumes.
| Two-Chamber View | Transversal View | |||||||||||||||
| LAA interobserver | LAA intra-observer | LA interobserver | LA intra-observer | LAA interobserver | LAA intra-observer | LA interobserver | LA intra-observer | |||||||||
| ICC | CV% | ICC | CV% | ICC | CV% | ICC | CV% | ICC | CV% | ICC | CV% | ICC | CV% | ICC | CV% | |
| Excellent | 0.929 | 10.1 | 0.978 | 6.0 | 0.977 | 4.3 | 0.998 | 1.7 | 0.976 | 5.3 | 0.939 | 8.1 | 0.967 | 8.3 | 0.995 | 3.3 |
| Good | 0.970 | 13.3 | 0.988 | 9.1 | 0.987 | 4.6 | 0.988 | 3.6 | 0.943 | 21.0 | 0.988 | 8.2 | 0.948 | 8.9 | 0.979 | 5.8 |
| Average | 0.927 | 18.2 | 0.984 | 5.5 | 0.946 | 11.1 | 0.996 | 3.1 | 0.972 | 8.6 | 0.984 | 8.0 | 0.970 | 9.0 | 0.998 | 2.8 |
| Poor | 0.978 | 12.3 | 0.995 | 5.0 | 0.972 | 6.9 | 0.989 | 5.2 | 0.946 | 17.2 | 0.954 | 13.7 | 0.905 | 14.5 | 0.985 | 5.5 |
| Total | 0.960 | 13.5 | 0.988 | 6.4 | 0.996 | 6.7 | 0.992 | 3.4 | 0.953 | 13.0 | 0.970 | 9.5 | 0.944 | 10.2 | 0.989 | 4.3 |
Forty measurements pairs included 10 patients from each image quality category.
Intertechnique Reproducibility of Left Atrial Appendage and Left Atrium Volume Measurements.
| Measurement Pairs | Left Atrial Appendage | Left Atrium | |||
| Image Quality | N | ICC | CV% | ICC | CV% |
| Excellent | 50 | 0.917 | 9.8 | 0.965 | 7.3 |
| Good | 50 | 0.963 | 13.5 | 0.944 | 8.0 |
| Average | 50 | 0.957 | 12.1 | 0.949 | 9.8 |
| Poor | 50 | 0.953 | 14.1 | 0.930 | 10.6 |
| Interobserver | 80 | 0.949 | 13.0 | 0.931 | 9.4 |
| Intra-observer | 120 | 0.957 | 12.0 | 0.955 | 8.6 |
| Total | 200 | 0.954 | 12.4 | 0.945 | 8.9 |
Two hundred measurement pairs: 80 pairs with different observers and 120 pairs with the same observer.
Figure 2The reproducibility of volume measurements.
Bland-Altman plots show the reproducibility of 40 left atrium and 40 left atrial appendage volume measurements for the same observer and different observers in two-chamber view and the transversal view. The X-axis shows the mean of two volume measurements and the y-axis shows a difference between respective measurements. The middle line corresponds to the mean difference and the outer lines correspond to the 95% confidence interval. Filled squares (▪) indicate cardiac computed tomography images with excellent image quality; filled circles (•) indicate good image quality; empty circles (), moderate image quality; and empty squares (□), poor image quality. Volume size and image quality had no significant influence on interobserver or intra-observer measurements in either orientation.
Figure 3The intertechnique reproducibility of volume measurements.
Bland-Altman plots show the intertechnique reproducibility of 200 left atrium and 200 left atrial appendage volume measurements performed in two-chamber view or transversal view. The X-axis shows the mean of two volume measurements and the y-axis shows the difference between respective measurements. The middle line corresponds to the mean difference and the outer lines correspond to the 95% confidence interval. Filled circles (•) indicate 80 interobserver measurement and empty circles () 120 intra-observer measurements performed in the two orientations. Volume size and observer had no significant influence on the measurements.