| Literature DB >> 19335908 |
Ramin Artang1, Raymond Q Migrino, Leanne Harmann, Mark Bowers, Timothy D Woods.
Abstract
OBJECTIVE: Left atrial size is an important marker for adverse cardiovascular events. There is general consensus that left atrial volume index (LAVI) is the best measurement of size. The current LAVI measurement techniques are laborious. Semi-automated measurement with a 3-dimensional echocardiography (3DE) system may be a practical clinical alternative to measure LAVI, but it has not been adequately evaluated against Magnetic Resonance Imaging (MRI) gold standard. The aim of this study was to compare the accuracy of a commercially available 3D algorithm for measurement of LAVI against LAVI obtained from MRI and Area Length Method (ALM).Entities:
Mesh:
Year: 2009 PMID: 19335908 PMCID: PMC2669050 DOI: 10.1186/1476-7120-7-16
Source DB: PubMed Journal: Cardiovasc Ultrasound ISSN: 1476-7120 Impact factor: 2.062
Figure 1Semi automatic left atrial border tracing by marking (●) at 4 mitral annular points (lateral, septal, inferior, anterior) and an atrial superior dome point opposite the annulus (A). The automatic border tracing is then shown by the software. The left atrial end diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) are calculated automatically by the software and displayed on the right side of the screen (B). SV = stroke volume.
Figure 2MRI of left atrium. Steady state free precession cine gradient echo was performed on sequential slices of the left atrium. The left atrial border was traced at end-left ventricular systole. The summation of the areas multiplied by slice thickness is the left atrial volume. LA = left atrium, RA = right atrium, LV = left ventricle.
Baseline characteristics of the included subjects
| Number of subjects | 27 |
| Age (years) | 54 ± 13 |
| Male (%) | 17 (63) |
| Indication for MRI (%) | |
| Myocardial viability | 9 (33) |
| Amyloidosis | 3 (11) |
| Congestive heart failure | 6 (22) |
| ARVD† | 6 (22) |
| Coarctation of Aorta | 1 (4) |
| Pulmonary artery stenosis | 1 (4) |
| Patent ductus arteriosus | 1 (4) |
† Arrhythmogenic Right Ventricular Dysplasia
Figure 3The correlation analysis (top) and Bland-Altman analysis (bottom) of comparison between 3 dimensional echocardiography (3DE) and magnetic resonance imaging (MRI). SD = Standard Deviation.
Figure 4The correlation analysis between diastolic volumes by area-length method (ALM) vs. magnetic resonance imaging (MRI) (A), and 3 dimensional echocardiography (3DE) vs. ALM (B).
The intra- and interobserver variability among the different methods in percent
| Semiautomated 3D Technique | 2 | 5.1 |
| Magnetic Resonance Imaging | 1.8 | 6.4 |
| Area Length Method | 9.9 | 12.4 |