Literature DB >> 2498467

Accurate determination of end-tidal carbon dioxide during administration of oxygen by nasal cannulae.

E A Bowe1, P G Boysen, J A Broome, E F Klein.   

Abstract

Measurement of end-tidal carbon dioxide tension (PETCO2) by mass spectrometry or infrared capnometry provides a clinically useful approximation of arterial carbon dioxide tension (PaCO2) in intubated patients. Although several devices have been proposed to sample PETCO2 during spontaneous breathing (i.e., unintubated patients receiving supplemental oxygen), thus far no reports have documented their efficacy. This article reports the use of an easily constructed modification of simple nasal cannulae that permits accurate sampling of PETCO2 during oxygen administration to unintubated patients. After amputation of the closed tip, a cap from a syringe was inserted via a slit made at the base into one prong of a pair of nasal cannulae. A capnometer was connected to the syringe cap, and PETCO2 and PaCO2 were determined simultaneously during the administration of 3 L/min oxygen via nasal cannulae to 21 normocapnic patients. The PaCO2 - PETCO2 gradients were calculated and compared with values obtained in the same patients after intubation and mechanical ventilation. No significant difference was found between the calculated gradients with nasal cannulae (2.09 +/- 2.18 mm Hg) versus intubation (2.87 +/- 2.82 mm Hg). Simultaneous oxygen administration and accurate sampling of PETCO2 may be achieved in unintubated patients by using this easily constructed modification of nasal cannulae.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2498467     DOI: 10.1007/bf01617883

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  12 in total

1.  Respiratory dead space and arterial to end-tidal carbon dioxide tension difference in anesthetized man.

Authors:  J F NUNN; D W HILL
Journal:  J Appl Physiol       Date:  1960-05       Impact factor: 3.531

2.  Better designs for mass spectrometer monitoring of the awake patient.

Authors:  E A Norman; N J Zeig; I Ahmad
Journal:  Anesthesiology       Date:  1986-05       Impact factor: 7.892

3.  A simple, easy, and inexpensive method for monitoring ETCO2 through nasal cannulae.

Authors:  J M Goldman
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

4.  The validity and usefulness of the end-tidal pCO 2 during anaesthesia.

Authors:  S Takki; U Aromaa; A Kauste
Journal:  Ann Clin Res       Date:  1972-10

5.  Effects of varying respiratory waveforms on gas exchange.

Authors:  N A Bergman
Journal:  Anesthesiology       Date:  1967 Mar-Apr       Impact factor: 7.892

6.  Effect on pulmonary gas exchange of variations in inspiratory flow rate during intermittent positive pressure ventilation.

Authors:  H B Fairley; G D Blenkarn
Journal:  Br J Anaesth       Date:  1966-05       Impact factor: 9.166

7.  Accuracy of expired carbon dioxide partial pressure sampled from a nasal cannula.

Authors: 
Journal:  Anesthesiology       Date:  1988-06       Impact factor: 7.892

8.  A simple method of measuring ETCO2 during MAC and major regional anesthesia.

Authors:  M A Pressman
Journal:  Anesth Analg       Date:  1988-09       Impact factor: 5.108

9.  Mass spectrometer monitoring of patients with regional anesthesia.

Authors:  E Ibarra; D E Lees
Journal:  Anesthesiology       Date:  1985-11       Impact factor: 7.892

10.  Variation in PCO2 between arterial blood and peak expired gas during anesthesia.

Authors:  D B Raemer; D Francis; J H Philip; R A Gabel
Journal:  Anesth Analg       Date:  1983-12       Impact factor: 5.108

View more
  9 in total

Review 1.  Capnometry and anaesthesia.

Authors:  K Bhavani-Shankar; H Moseley; A Y Kumar; Y Delph
Journal:  Can J Anaesth       Date:  1992-07       Impact factor: 5.063

2.  Correlations between capnographic waveforms and peak flow meter measurement in emergency department management of asthma.

Authors:  N A R Nik Hisamuddin; A Rashidi; K S Chew; J Kamaruddin; Z Idzwan; A H Teo
Journal:  Int J Emerg Med       Date:  2009-02-24

3.  American Society of Dentist Anesthesiologists: Parameters of Care.

Authors: 
Journal:  Anesth Prog       Date:  2018

4.  Relationship between arterial carbon dioxide and end-tidal carbon dioxide when a nasal sampling port is used.

Authors:  S E McNulty; J Roy; M Torjman; J L Seltzer
Journal:  J Clin Monit       Date:  1990-04

5.  End tidal carbon dioxide as a predictor of the arterial PCO2 in the emergency department setting.

Authors:  C Yosefy; E Hay; Y Nasri; E Magen; L Reisin
Journal:  Emerg Med J       Date:  2004-09       Impact factor: 2.740

6.  End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: accuracy and sources of error.

Authors:  R H Friesen; M Alswang
Journal:  J Clin Monit       Date:  1996-03

7.  Evaluation of two commercially available carbon dioxide sampling nasal cannulae.

Authors:  J V Roth; L J Barth; L H Womack; L E Morgenlander
Journal:  J Clin Monit       Date:  1994-07

8.  An improved nasal prong apparatus for end-tidal carbon dioxide monitoring in awake, sedated patients.

Authors:  J Roy; S E McNulty; M C Torjman
Journal:  J Clin Monit       Date:  1991-07

9.  Capnographic monitoring of ventilatory status during moderate (conscious) sedation.

Authors:  L G Koniaris; S Wilson; G Drugas; W Simmons
Journal:  Surg Endosc       Date:  2003-06-13       Impact factor: 4.584

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.