Literature DB >> 24973020

Influence of blood/tissue differences in contrast agent relaxivity on tracer-based MR perfusion measurements.

Arvid Morell1, Fredrik Lennmyr, Ove Jonsson, Thomas Tovedal, Jean Pettersson, Jonas Bergquist, Vitas Zemgulis, Gunnar Myrdal Einarsson, Stefan Thelin, Håkan Ahlström, Atle Bjørnerud.   

Abstract

PURPOSE: Perfusion assessment by monitoring the transport of a tracer bolus depends critically on conversion of signal intensity into tracer concentration. Two main assumptions are generally applied for this conversion; (1) contrast agent relaxivity is identical in blood and tissue, (2) change in signal intensity depends only on the primary relaxation effect. The purpose of the study was to assess the validity and influence of these assumptions.
MATERIALS AND METHODS: Blood and cerebral tissue relaxivities r1, r2, and r2* for gadodiamide were measured in four pigs at 1.5 T. Gadolinium concentration was determined by inductively coupled plasma atomic emission spectroscopy. Influence of the relaxivities, secondary relaxation effects and choice of singular value decomposition (SVD) regularization threshold was studied by simulations.
RESULTS: In vivo relaxivities relative to blood concentration [in s(-1) mM(-1) for blood, gray matter (GM), white matter (WM)] were for r1 (2.614 ± 1.061, 0.010 ± 0.001, 0.004 ± 0.002), r2 (5.088 ± 0.952, 0.091 ± 0.008, 0.059 ± 0.014), and r2* (13.292 ± 3.928, 1.696 ± 0.157, 0.910 ± 0.139). Although substantial, by a nonparametric test for paired samples, the differences were not statistically significant. The GM to WM blood volume ratio was estimated to 2.6 ± 0.9 by r1, 1.6 ± 0.3 by r2, and 1.9 ± 0.2 by r2*. Secondary relaxation was found to reduce the tissue blood flow, as did the SVD regularization threshold.
CONCLUSION: Contrast agent relaxivity is not identical in blood and tissue leading to substantial errors. Further errors are introduced by secondary relaxation effects and the SVD regularization.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24973020     DOI: 10.1007/s10334-014-0452-5

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  36 in total

1.  Renal T(*)(2) perfusion using an iron oxide nanoparticle contrast agent--influence of T(1) relaxation on the first-pass response.

Authors:  Atle Bjørnerud; Lars O Johansson; Håkan K Ahlström
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

2.  Accuracy of deconvolution analysis based on singular value decomposition for quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging.

Authors:  K Murase; M Shinohara; Y Yamazaki
Journal:  Phys Med Biol       Date:  2001-12       Impact factor: 3.609

3.  Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition.

Authors:  F Calamante; D G Gadian; A Connelly
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

4.  Regional cerebral blood volume: a comparison of the dynamic imaging and the steady state methods.

Authors:  W Lin; A Celik; R P Paczynski
Journal:  J Magn Reson Imaging       Date:  1999-01       Impact factor: 4.813

5.  Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation.

Authors:  B F Kjølby; L Østergaard; V G Kiselev
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

6.  Nonlinear DeltaR*2 effects in perfusion quantification using bolus-tracking MRI.

Authors:  Fernando Calamante; Alan Connelly; Matthias J P van Osch
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

7.  A fully automated method for quantitative cerebral hemodynamic analysis using DSC-MRI.

Authors:  Atle Bjørnerud; Kyrre E Emblem
Journal:  J Cereb Blood Flow Metab       Date:  2010-01-20       Impact factor: 6.200

8.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis.

Authors:  L Ostergaard; R M Weisskoff; D A Chesler; C Gyldensted; B R Rosen
Journal:  Magn Reson Med       Date:  1996-11       Impact factor: 4.668

9.  Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T1-weighted MRI at 3T.

Authors:  Henrik B W Larsson; Adam E Hansen; Hilde K Berg; Egill Rostrup; Olav Haraldseth
Journal:  J Magn Reson Imaging       Date:  2008-04       Impact factor: 4.813

10.  Database of normal human cerebral blood flow, cerebral blood volume, cerebral oxygen extraction fraction and cerebral metabolic rate of oxygen measured by positron emission tomography with 15O-labelled carbon dioxide or water, carbon monoxide and oxygen: a multicentre study in Japan.

Authors:  Hiroshi Ito; Iwao Kanno; Chietsugu Kato; Toshiaki Sasaki; Kenji Ishii; Yasuomi Ouchi; Akihiko Iida; Hidehiko Okazawa; Kohei Hayashida; Naohiro Tsuyuguchi; Kazunari Ishii; Yasuo Kuwabara; Michio Senda
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-17       Impact factor: 9.236

View more
  2 in total

1.  Dynamic susceptibility contrast perfusion MRI using phase-based venous output functions: comparison with pseudo-continuous arterial spin labelling and assessment of contrast agent concentration in large veins.

Authors:  Ronnie Wirestam; Emelie Lind; André Ahlgren; Freddy Ståhlberg; Linda Knutsson
Journal:  MAGMA       Date:  2016-06-13       Impact factor: 2.310

2.  Variability in Quantitative DCE-MRI: Sources and Solutions.

Authors:  Harrison Kim
Journal:  J Nat Sci       Date:  2018
  2 in total