Literature DB >> 24970252

Reducing variability in visual field assessment for glaucoma through filtering that combines structural and functional information.

Lisha Deng1, Shaban Demirel1, Stuart K Gardiner1.   

Abstract

PURPOSE: To reduce variability and improve measurements of true change signal in visual field (VF) assessments through the use of filters that combine functional and structural test results.
METHODS: Humphrey VF data (Swedish Interactive Thresholding Algorithm [SITA] Standard, 24-2) and confocal scanning laser ophthalmoscopy (Heidelberg Retina Tomograph [HRT]) data from 1057 eyes of 637 participants were used to derive a filter. Another dataset, consisting of VF and HRT data from 112 eyes of 62 participants each with ≥5 visits, was used to test the filter. At each VF location per eye, the trend over time was modeled by a linear model (LM), and a nonlinear model (NLM), using filtered or unfiltered data, but with the last visit excluded. The SD of residuals from the trends, and prediction errors (PE) for the last visit were compared between filtered and unfiltered data. The filter was reconstructed and analyses were repeated after truncating VF data so that thresholds < 19 dB were replaced by 19 dB to reduce noise.
RESULTS: The SD of the residuals at all 52 VF locations for all analyses was reduced by filtering (P < 0.001). The PE was reduced by filtering at 43 and 47 VF locations (P < 0.05) for LM analyses on observed and truncated data, and all 52 VF locations (P < 0.05) for both NLM analyses. Truncating data before filtering reduced variability (P < 0.01) at 41 and 40 VF locations for LM and NLM analyses.
CONCLUSIONS: Filtering can reduce variability about trends in longitudinal sequences of VF data, and improves the accuracy of predicting the next test result. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

Entities:  

Keywords:  CSLO; automated perimetry; variability

Mesh:

Year:  2014        PMID: 24970252      PMCID: PMC4112605          DOI: 10.1167/iovs.13-13813

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  45 in total

1.  Scaling the hill of vision: the physiological relationship between light sensitivity and ganglion cell numbers.

Authors:  D F Garway-Heath; J Caprioli; F W Fitzke; R A Hitchings
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-06       Impact factor: 4.799

2.  Neural losses correlated with visual losses in clinical perimetry.

Authors:  Ronald S Harwerth; Louvenia Carter-Dawson; Earl L Smith; George Barnes; William F Holt; Morris L J Crawford
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-09       Impact factor: 4.799

3.  Test-retest variability in glaucomatous visual fields.

Authors:  A Heijl; A Lindgren; G Lindgren
Journal:  Am J Ophthalmol       Date:  1989-08-15       Impact factor: 5.258

Review 4.  Identification of progressive glaucomatous visual field loss.

Authors:  Paul G D Spry; Chris A Johnson
Journal:  Surv Ophthalmol       Date:  2002 Mar-Apr       Impact factor: 6.048

5.  The temporal raphe of the human retina.

Authors:  F Vrabec
Journal:  Am J Ophthalmol       Date:  1966-11       Impact factor: 5.258

6.  The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma.

Authors:  Michael A Kass; Dale K Heuer; Eve J Higginbotham; Chris A Johnson; John L Keltner; J Philip Miller; Richard K Parrish; M Roy Wilson; Mae O Gordon
Journal:  Arch Ophthalmol       Date:  2002-06

7.  Spatial and temporal processing of threshold data for detection of progressive glaucomatous visual field loss.

Authors:  Paul G D Spry; Chris A Johnson; Alex B Bates; Andrew Turpin; Balwantray C Chauhan
Journal:  Arch Ophthalmol       Date:  2002-02

8.  Differential light threshold. Short- and long-term fluctuation in patients with glaucoma, normal controls, and patients with suspected glaucoma.

Authors:  J Flammer; S M Drance; M Zulauf
Journal:  Arch Ophthalmol       Date:  1984-05

9.  Reducing noise in suspected glaucomatous visual fields by using a new spatial filter.

Authors:  Stuart K Gardiner; David P Crabb; Fred W Fitzke; Roger A Hitchings
Journal:  Vision Res       Date:  2004-04       Impact factor: 1.886

10.  Assessment of the reliability of standard automated perimetry in regions of glaucomatous damage.

Authors:  Stuart K Gardiner; William H Swanson; Deborah Goren; Steven L Mansberger; Shaban Demirel
Journal:  Ophthalmology       Date:  2014-03-12       Impact factor: 12.079

View more
  2 in total

1.  Reducing Variability of Perimetric Global Indices from Eyes with Progressive Glaucoma by Censoring Unreliable Sensitivity Data.

Authors:  Manoj Pathak; Shaban Demirel; Stuart K Gardiner
Journal:  Transl Vis Sci Technol       Date:  2017-07-20       Impact factor: 3.283

2.  Factors Associated with Midterm Visual Field Variability in Patients with Stable Glaucoma.

Authors:  Maria Emília V Guimarães; Carolina P B Gracitelli; Syril Dorairaj; Fábio N Kanadani; Tiago S Prata
Journal:  J Ophthalmol       Date:  2019-12-09       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.