Literature DB >> 24968172

Robust carotid artery recognition in longitudinal B-mode ultrasound images.

Emmanouil G Sifakis, Spyretta Golemati.   

Abstract

Automatic segmentation of the arterial lumen from ultrasound images is an important task in clinical diagnosis. Carotid artery recognition, the first task in lumen segmentation, should be performed in a fully automated, fast, and reliable way to further facilitate the low-level task of arterial delineation. In this paper, a user-independent, real-time algorithm is introduced for carotid artery localization in longitudinal B-mode ultrasound images. The proposed technique acts directly on the raw image, and exploits basic statistics along with anatomical knowledge. The method's evaluation and parameter value optimization were performed on a threefold cross validation basis. In addition, the introduced algorithm was systematically compared with another algorithm for common carotid artery recognition in B-mode scans, separately for multi-frame and single-frame data. The data sets used included 2,149 images from 100 subjects taken from three different institutions and covering a wide range of possible lumen and surrounding tissue representations. Using the optimized values, the carotid artery was recognized in all the processed images in both multi-frame and single-frame data. Thus, the introduced technique will further reinforce automatic segmentation in longitudinal B-mode ultrasound images.

Mesh:

Year:  2014        PMID: 24968172     DOI: 10.1109/TIP.2014.2332761

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  3 in total

1.  Two Automated Techniques for Carotid Lumen Diameter Measurement: Regional versus Boundary Approaches.

Authors:  Tadashi Araki; P Krishna Kumar; Harman S Suri; Nobutaka Ikeda; Ajay Gupta; Luca Saba; Jeny Rajan; Francesco Lavra; Aditya M Sharma; Shoaib Shafique; Andrew Nicolaides; John R Laird; Jasjit S Suri
Journal:  J Med Syst       Date:  2016-06-14       Impact factor: 4.460

2.  Accurate lumen diameter measurement in curved vessels in carotid ultrasound: an iterative scale-space and spatial transformation approach.

Authors:  P Krishna Kumar; Tadashi Araki; Jeny Rajan; Luca Saba; Francesco Lavra; Nobutaka Ikeda; Aditya M Sharma; Shoaib Shafique; Andrew Nicolaides; John R Laird; Ajay Gupta; Jasjit S Suri
Journal:  Med Biol Eng Comput       Date:  2016-12-10       Impact factor: 2.602

3.  Emerging Feature Extraction Techniques for Machine Learning-Based Classification of Carotid Artery Ultrasound Images.

Authors:  S Latha; P Muthu; Samiappan Dhanalakshmi; R Kumar; Khin Wee Lai; Xiang Wu
Journal:  Comput Intell Neurosci       Date:  2022-05-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.