| Literature DB >> 24965884 |
S R Byers1, O M Beemer, A S Lear, R J Callan.
Abstract
BACKGROUND: Persistent hyperglycemia is common in alpacas and typically requires insulin administration for resolution; however, little is known about alpacas' response to different insulin formulations.Entities:
Keywords: Hyperglycemia; Insulin glargine; NPH insulin; Regular insulin
Mesh:
Substances:
Year: 2014 PMID: 24965884 PMCID: PMC4895571 DOI: 10.1111/jvim.12389
Source DB: PubMed Journal: J Vet Intern Med ISSN: 0891-6640 Impact factor: 3.333
Figure 1Components of a continuous glucose monitoring system evaluated for use in alpacas (left). Continuous glucose monitor sensor and transmitter attached to the left paralumbar fossa of an alpaca (right). A – Sensor and insertion device; B – Transmitter; C – Receiver.
Blood glucose results after administration of 3 types of insulin to 6 healthy alpacas. Nadir represents the minimum blood glucose concentration, peak response is the time required to reach the nadir, and duration is the amount of time the blood glucose remained less than our laboratory minimum reference interval of 90 mg/dL.
| Insulin Form | Route | Dosage (U/kg) | Nadir ± SD (mg/dL) | Mean Peak Response ± SD (hours) | Mean Duration <90 mg/dL ± SD (hours) |
|---|---|---|---|---|---|
| Regular | IV | 0.2 | 45 ± 15 | 2 ± 1 | 3.4 ± 1 |
| Regular | SC | 0.2 | 42 ± 19 | 4.7 ± 0.9 | 8.5 ± 1.9 |
| NPH | SC | 0.4 | 45 ± 21 | 4.7 ± 0.9 | 15.4 ± 6.2 |
| Glargine | SC | 0.4 | 64 ± 29 | 12.5 ± 3.3 | 10.5 ± 4.4 |
Figure 2Continuous glucose monitor and point of care (POC) glucometer data for regular insulin IV and SC, NPH insulin SC, insulin glargine SC, and dextrose IV. The solid line with squares represents the POC glucose readings. The solid line without markers represents the continuous glucose monitoring (CGM) glucose data. Error bars for the CGM were calculated at 15 minute intervals. The * indicates where IV dextrose was given either due signs of hypoglycemia or POC glucometer reading of “LO” or 20 mg/dL.
Figure 3Bland‐Altman difference plot (A) and Deming regression analysis (B) for glucose concentrations from the point of care glucometer and continuous glucose monitoring for all insulin types and dextrose. The intercept coefficient (± SE) for the Deming regression analysis was −21.86 (±3.97) with a 95% confidence interval of −29.67 to −14.04. The slope coefficient (± SE) was 1.04 (± 0.04) with a 95% CI of 0.96–1.12. Graph shapes represent the 6 different alpacas.
Figure 4Error grid plot and analysis comparing point of care glucose and continuous glucose monitoring readings after administration of various insulin and dextrose doses to 6 alpacas. See text for description of the zones. The percentages of samples for each of the zones were as follows: Zone A 90.1%, zone B 9.1%, zone C 0.8%, and zone D 0%, respectively. The various shapes represent the 6 alpacas.