Consideration of slice profiles in inversion recovery Look-Locker relaxation parameter mapping.

Johannes Tran-Gia1, Tobias Wech2, Dietbert Hahn3, Thorsten A Bley2, Herbert Köstler2.   

Abstract

PURPOSE: To include the flip angle distribution caused by the slice profile into the model used for describing the relaxation curves observed in inversion recovery Look-Locker FLASH T1 mapping for a more accurate determination of the relaxation parameters.
MATERIALS AND METHODS: For each inversion time, the flip angle dependent signal of the mono-exponential relaxation model is integrated across the slice profile. The resulting Consideration of Slice Profiles (CSP) relaxation curves are compared to the mono-exponential signal model in numerical simulations as well as in phantom and in-vivo experiments.
RESULTS: All measured relaxation curves showed systematic deviations from a mono-exponential curve increasing with flip angle and T1 but decreasing with repetition time. Additionally, the accuracy of T1 was found to be largely dependent on the temporal coverage of the relaxation curve. All these systematic errors were largely reduced by the CSP model.
CONCLUSION: The proposed CSP model represents a useful extension of the conventionally used mono-exponential relaxation model. Despite inherent model inaccuracies, the mono-exponential model was found to be sufficient for many T1 mapping situations. However, if only a poor temporal coverage of the relaxation process is achievable or a very precise modeling of the relaxation course is needed as in model-based techniques, the mono-exponential model leads to systematic errors and the CSP model should be used instead.
Copyright © 2014 Elsevier Inc. All rights reserved.

Keywords:  Flip angle distribution; Imperfect slice excitation profile; Inversion recovery magnetization preparation; Look–Locker technique; Quantitative imaging; T(1) mapping

Mesh:

Substances:

Year:  2014        PMID: 24960366     DOI: 10.1016/j.mri.2014.05.012

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm.

Authors:  Jiaxin Shao; Stanislas Rapacchi; Kim-Lien Nguyen; Peng Hu
Journal:  J Magn Reson Imaging       Date:  2015-07-27       Impact factor: 4.813

2.  Investigating and reducing the effects of confounding factors for robust T1 and T2 mapping with cardiac MR fingerprinting.

Authors:  Jesse I Hamilton; Yun Jiang; Dan Ma; Wei-Ching Lo; Vikas Gulani; Mark Griswold; Nicole Seiberlich
Journal:  Magn Reson Imaging       Date:  2018-06-30       Impact factor: 2.546

3.  Model-based acceleration of look-locker T1 mapping.

Authors:  Johannes Tran-Gia; Tobias Wech; Thorsten Bley; Herbert Köstler
Journal:  PLoS One       Date:  2015-04-10       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.