Literature DB >> 24959520

Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants.

Sudhindra Mahoorkar1, Anoop Jain2, Cauvery K3, Pawan Kumar4, Raghavendra Havale5.   

Abstract

An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques.

Entities:  

Keywords:  Dental implants; Dental impression technique; Fixture mount; Impression; Impression coping

Year:  2014        PMID: 24959520      PMCID: PMC4064874          DOI: 10.7860/JCDR/2014/7623.4280

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  10 in total

Review 1.  Implants and components: entering the new millennium.

Authors:  P P Binon
Journal:  Int J Oral Maxillofac Implants       Date:  2000 Jan-Feb       Impact factor: 2.804

2.  Generic terminology for endosseous implant prosthodontics.

Authors:  C E Misch; C M Misch
Journal:  J Prosthet Dent       Date:  1992-11       Impact factor: 3.426

3.  Prosthodontic application for implant carriers.

Authors:  Mario R Ganddini; Nestor Schejtman; Carlo Ercoli; Gerald N Graser
Journal:  J Prosthet Dent       Date:  2004-10       Impact factor: 3.426

4.  Making an implant-level impression using solid plastic, press-fit, closed-tray impression copings: a clinical report.

Authors:  Audrey M Selecman; Russell A Wicks
Journal:  J Prosthet Dent       Date:  2009-03       Impact factor: 3.426

5.  Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection.

Authors:  Hans-Jürgen Wenz; Katrin Hertrampf
Journal:  Int J Oral Maxillofac Implants       Date:  2008 Jan-Feb       Impact factor: 2.804

6.  Useful modifications of an implant fixture mount.

Authors:  G R McCarthy; V L Morgan
Journal:  J Prosthet Dent       Date:  1995-01       Impact factor: 3.426

7.  The role of the implant impression in abutment selection: a technical note.

Authors:  H K Kupeyan; B R Lang
Journal:  Int J Oral Maxillofac Implants       Date:  1995 Jul-Aug       Impact factor: 2.804

8.  Four uses of a disposable implant mount.

Authors:  S Papazian; S M Morgano
Journal:  J Prosthet Dent       Date:  1998-02       Impact factor: 3.426

9.  Accuracy of implant impression techniques.

Authors:  D Assif; B Marshak; A Schmidt
Journal:  Int J Oral Maxillofac Implants       Date:  1996 Mar-Apr       Impact factor: 2.804

10.  Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well.

Authors:  Glenn Hsuan-Chen Chang; Chen Tian; Yuen-Siang Hung
Journal:  Contemp Clin Dent       Date:  2011-07
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.