Literature DB >> 24956295

Contrast-enhanced dual-energy mammography: a promising new imaging tool in breast cancer detection.

Ulrich Lalji1, Marc Lobbes.   

Abstract

Contrast-enhanced dual-energy mammography (CEDM) is a promising new breast imaging tool for breast cancer detection. In CEDM, an iodine-based contrast agent is intravenously administered and subsequently, dual-energy mammography is performed. This results in a set of images containing both a regular mammogram and an image that contains contrast enhancement information. Preliminary studies have indicated that CEDM is superior to conventional mammography and might even match the diagnostic performance of breast MRI. In this review, the imaging technique, protocol and patient handling of CEDM is presented. Furthermore, an overview of current results on CEDM and potential future indications are outlined.

Entities:  

Keywords:  CEDM; breast cancer; contrast-enhanced mammography; mammography

Mesh:

Substances:

Year:  2014        PMID: 24956295     DOI: 10.2217/whe.14.18

Source DB:  PubMed          Journal:  Womens Health (Lond)        ISSN: 1745-5057


  5 in total

1.  Contrast enhanced dual energy spectral mammogram, an emerging addendum in breast imaging.

Authors:  Kalpana D Kariyappa; Francis Gnanaprakasam; Subhapradha Anand; Murali Krishnaswami; Madan Ramachandran
Journal:  Br J Radiol       Date:  2016-09-09       Impact factor: 3.039

2.  The impact of contrast-enhanced spectral mammogram (CESM) and three-dimensional breast ultrasound (3DUS) on the characterization of the disease extend in cancer patients.

Authors:  Maha Hussien Helal; Sahar Mahmoud Mansour; Lamia Adel Salaleldin; Basma Mohamed Alkalaawy; Dorria Saleh Salem; Nadia Mahmoud Mokhtar
Journal:  Br J Radiol       Date:  2018-05-24       Impact factor: 3.039

3.  Evaluation of low-energy contrast-enhanced spectral mammography images by comparing them to full-field digital mammography using EUREF image quality criteria.

Authors:  U C Lalji; C R L P N Jeukens; I Houben; P J Nelemans; R E van Engen; E van Wylick; R G H Beets-Tan; J E Wildberger; L E Paulis; M B I Lobbes
Journal:  Eur Radiol       Date:  2015-03-27       Impact factor: 5.315

4.  Evaluation of exposure factors of dual-energy contrast-enhanced mammography to optimize radiation dose with improved image quality.

Authors:  Sachila Niroshani; Tokiko Nakamura; Nikaidou Michiru; Toru Negishi
Journal:  Acta Radiol Open       Date:  2022-08-11

5.  Contrast-enhanced spectral mammography in recalls from the Dutch breast cancer screening program: validation of results in a large multireader, multicase study.

Authors:  U C Lalji; I P L Houben; R Prevos; S Gommers; M van Goethem; S Vanwetswinkel; R Pijnappel; R Steeman; C Frotscher; W Mok; P Nelemans; M L Smidt; R G Beets-Tan; J E Wildberger; M B I Lobbes
Journal:  Eur Radiol       Date:  2016-04-20       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.