Literature DB >> 24948790

Dose reduction for chest CT: comparison of two iterative reconstruction techniques.

Sarvenaz Pourjabbar1, Sarabjeet Singh2, Naveen Kulkarni2, Victorine Muse2, Subba R Digumarthy2, Ranish Deedar Ali Khawaja2, Atul Padole2, Synho Do2, Mannudeep K Kalra2.   

Abstract

BACKGROUND: Lowering radiation dose in computed tomography (CT) scan results in low quality noisy images. Iterative reconstruction techniques are used currently to lower image noise and improve the quality of images.
PURPOSE: To evaluate lesion detection and diagnostic acceptability of chest CT images acquired at CTDIvol of 1.8 mGy and processed with two different iterative reconstruction techniques.
MATERIAL AND METHODS: Twenty-two patients (mean age, 60 ± 14 years; men, 13; women, 9; body mass index, 27.4 ± 6.5 kg/m(2)) gave informed consent for acquisition of low dose (LD) series in addition to the standard dose (SD) chest CT on a 128 - multidetector CT (MDCT). LD images were reconstructed with SafeCT C4, L1, and L2 settings, and Safire S1, S2, and S3 settings. Three thoracic radiologists assessed LD image series (S1, S2, S3, C4, L1, and L2) for lesion detection and comparison of lesion margin, visibility of normal structures, and diagnostic confidence with SD chest CT. Inter-observer agreement (kappa) was calculated.
RESULTS: Average CTDIvol was 6.4 ± 2.7 mGy and 1.8 ± 0.2 mGy for SD and LD series, respectively. No additional lesion was found in SD as compared to LD images. Visibility of ground-glass opacities and lesion margins, as well as normal structures visibility were not affected on LD. CT image visibility of major fissure and pericardium was not optimal in some cases (n = 5). Objective image noise in some low dose images processed with SafeCT and Safire was similar to SD images (P value > 0.5).
CONCLUSION: Routine LD chest CT reconstructed with iterative reconstruction technique can provide similar diagnostic information in terms of lesion detection, margin, and diagnostic confidence as compared to SD, regardless of the iterative reconstruction settings. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  CT spiral; Image manipulation/reconstruction; physics; radiation safety; thorax

Mesh:

Year:  2014        PMID: 24948790     DOI: 10.1177/0284185114537256

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  9 in total

1.  Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality.

Authors:  Boris Bodelle; Constanze Fischbach; Christian Booz; Ibrahim Yel; Claudia Frellesen; Moritz Kaup; Martin Beeres; Thomas J Vogl; Jan-Erik Scholtz
Journal:  Pediatr Radiol       Date:  2017-03-28

2.  Ultralow-dose CT with knowledge-based iterative model reconstruction (IMR) in evaluation of pulmonary tuberculosis: comparison of radiation dose and image quality.

Authors:  Chenggong Yan; Chunyi Liang; Jun Xu; Yuankui Wu; Wei Xiong; Huan Zheng; Yikai Xu
Journal:  Eur Radiol       Date:  2019-03-29       Impact factor: 5.315

3.  Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT.

Authors:  Ki Baek Lee; Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-01-02       Impact factor: 3.500

4.  Quantitative assessment of Pulmonary Alveolar Proteinosis (PAP) with ultra-dose CT and correlation with Pulmonary Function Tests (PFTs).

Authors:  Xin Sui; Qianni Du; Kai-Feng Xu; Xinlun Tian; Lan Song; Xiao Wang; Xiaoli Xu; Zixing Wang; Yuyan Wang; Jun Gu; Wei Song; Zhengyu Jin
Journal:  PLoS One       Date:  2017-03-16       Impact factor: 3.240

5.  Radiation dose reduction in chest dual-energy computed tomography: effect on image quality and diagnostic information.

Authors:  Rodrigo Canellas; Subba Digumarthy; Azadeh Tabari; Alexi Otrakji; Shaunagh McDermott; Efren J Flores; Mannudeep Kalra
Journal:  Radiol Bras       Date:  2018 Nov-Dec

6.  Application of Vendor-Neutral Iterative Reconstruction Technique to Pediatric Abdominal Computed Tomography.

Authors:  Woo Hyeon Lim; Young Hun Choi; Ji Eun Park; Yeon Jin Cho; Seunghyun Lee; Jung Eun Cheon; Woo Sun Kim; In One Kim; Jong Hyo Kim
Journal:  Korean J Radiol       Date:  2019-09       Impact factor: 3.500

7.  Evaluation of three-dimensional iterative image reconstruction in C-arm-based interventional cone-beam CT: A phantom study in comparison with customary reconstruction technique.

Authors:  Shigeru Suzuki; Yoshiaki Katada; Tomoko Takayanagi; Haruto Sugawara; Takuya Ishikawa; Yuzo Yamamoto; Hiroo Wada
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

8.  Highly reduced-dose CT of the lumbar spine in a human cadaver model.

Authors:  Malte Lennart Warncke; Nis Jesper Wiese; Enver Tahir; Susanne Sehner; Axel Heinemann; Marc Regier; Klaus Püschel; Gerhard Adam; Julius Matthias Weinrich; Azien Laqmani
Journal:  PLoS One       Date:  2020-10-08       Impact factor: 3.240

9.  Impact of dose reduction and iterative model reconstruction on multi-detector CT imaging of the brain in patients with suspected ischemic stroke.

Authors:  Karolin J Paprottka; Karina Kupfer; Isabelle Riederer; Claus Zimmer; Meinrad Beer; Peter B Noël; Thomas Baum; Jan S Kirschke; Nico Sollmann
Journal:  Sci Rep       Date:  2021-11-15       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.