Literature DB >> 24945511

Reasons for mini-implants failure: choosing installation site should be valued!

Alberto Consolaro, Fábio Lourenço Romano.   

Abstract

Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a) Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the structures, the more delicate they are, thus offering less physical support for mini-implant placement; b) Alveolar bone crests with triangular shape are more deformable, whereas those with rectangular shape are more flexible; c) The bases of the alveolar processes of the maxilla and the mandible are not flexible, for this reason, they are more likely to receive mini-implants; d) The more cervical a mini-implant is placed, the higher the risk of loss; the more apical a mini-implant is placed, the better its prognosis will be; e) 3D evaluations play a major role in planning the use of mini-implants. Based on the aforementioned considerations, the hypotheses about mini-implant loss are the following: 1) Deflection of maxillary and mandibular alveolar processes when mini-implants are more cervically placed; 2) Mini-implants placed too near the periodontal ligament, with normal intra-alveolar tooth movement; 3) Low bone density, low thickness and low alveolar bone volume; 4) Decreased alveolar cortical bone thickness; 5) Excessive pressure inducing trabecular bone microfracture; 6) Sites with higher anatomical weakness in the mandible and the maxilla; 7) Thicker gingival tissue not considered when choosing the mini-implant.

Entities:  

Keywords:  Absolute anchorage; Micro-screws; Mini-implants; Temporary anchorage devices

Mesh:

Substances:

Year:  2014        PMID: 24945511      PMCID: PMC4296612          DOI: 10.1590/2176-9451.19.2.018-024.oin

Source DB:  PubMed          Journal:  Dental Press J Orthod        ISSN: 2176-9451


  9 in total

1.  Development of orthodontic micro-implants for intraoral anchorage.

Authors:  Hee-Moon Kyung; Hyo-Sang Park; Seong-Min Bae; Jae-Hyun Sung; Il-Bong Kim
Journal:  J Clin Orthod       Date:  2003-06

2.  Clinical study of temporary anchorage devices for orthodontic treatment--stability of micro/mini-screws and mini-plates: experience with 455 cases.

Authors:  Takashi Takaki; Naoki Tamura; Masae Yamamoto; Nobuo Takano; Takahiko Shibahara; Toshihiko Yasumura; Yasushi Nishii; Kenji Sueishi
Journal:  Bull Tokyo Dent Coll       Date:  2010

3.  Osseointegration of miniscrews: a histomorphometric evaluation.

Authors:  Bart Vande Vannet; Mehran Moradi Sabzevar; Heinrich Wehrbein; Karlien Asscherickx
Journal:  Eur J Orthod       Date:  2007-10       Impact factor: 3.075

4.  Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study.

Authors:  Dirk Wiechmann; Ulrich Meyer; André Büchter
Journal:  Clin Oral Implants Res       Date:  2007-04       Impact factor: 5.977

Review 5.  Mini-implants in orthodontics: a systematic review of the literature.

Authors:  Reint Reynders; Laura Ronchi; Shandra Bipat
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-05       Impact factor: 2.650

Review 6.  Critical factors for the success of orthodontic mini-implants: a systematic review.

Authors:  Yan Chen; Hee Moon Kyung; Wen Ting Zhao; Won Jae Yu
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-03       Impact factor: 2.650

7.  Microbial colonization in orthodontic mini-implants.

Authors:  Amanda Osório Ayres de Freitas; Celuta Sales Alviano; Daniela Sales Alviano; José Freitas Siqueira; Lincoln Issamu Nojima; Matilde da Cunha Gonçalves Nojima
Journal:  Braz Dent J       Date:  2012

8.  Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage.

Authors:  Shouichi Miyawaki; Isao Koyama; Masahide Inoue; Katsuaki Mishima; Toshio Sugahara; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-10       Impact factor: 2.650

Review 9.  Insertion torque and success of orthodontic mini-implants: a systematic review.

Authors:  Reint A Meursinge Reynders; Laura Ronchi; Luisa Ladu; Faridi van Etten-Jamaludin; Shandra Bipat
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-11       Impact factor: 2.650

  9 in total
  2 in total

1.  Why are mini-implants lost: the value of the implantation technique!

Authors:  Fabio Lourenço Romano; Alberto Consolaro
Journal:  Dental Press J Orthod       Date:  2015 Jan-Feb

2.  Mechanical and histological evaluation of a titanium device for orthodontic anchorage, placed with or without cyanoacrylate adhesive.

Authors:  Anderson Antonio Mamede; Elizabeth Ferreira Martinez; Roberta Tarkany Basting
Journal:  Dental Press J Orthod       Date:  2019-08-01
  2 in total